Precision Medical EasyDial Reg Oxygen Regulator

Precision Medical EasyDial Reg Oxygen Regulator

Brand/Manufacturer: PRECISION MEDICAL, INC
Earn
4%

Reward$

  • Made in USA

Precision Medical EasyDial Reg Oxygen Regulator is intended to regulate flow of oxygen from a high pressure oxygen cylinder. The units easily accessible flow adjustment knob is large and knurled making flow adjustment a cinch, even for the physically challenged. Features a built-in pressure relief valve, as well as a protected contents gauge. Its unique design minimizes normal flow variation that occurs as tank pressure drops.

Why choose Precision Medical Regulator?

  • Compact and Lightweight 
  • Safe and accurate 
  • Flexible and versatile

Estimated Shipping Time: 4-8 Business Days
Item #DescPkg Price 
168708D 0 lpm to 8 lpm Each $2.75
$125.53
$68.72
165425D Nut Style, 0 lpm to 25 lpm Each $2.75
$125.53
$68.72
168715D 0 lpm to 15 lpm Each $2.99
$131.93
$74.85
168725D 0 lpm to 25 lpm Each $2.99
$131.93
$74.85
165408D Nut Style, 0 lpm to 8 lpm Each $3.43
$156.82
$85.82
165415D Nut Style, 0 lpm to 15 lpm Each $3.43
$156.82
$85.82
168704DL Pediatric, 0 lpm to 4 lpm Each $4.14
$158.18
$103.40

EasyDial Reg Oxygen Regulator Features

  • Easygauge reg comes in two body designs and two flow ranges, they are flexible and versatile
  • Accurate: Unique design minimizes normal flow variation that occurs as tank pressure drops
  • Low force Viton yoke seal provides a better tank-to-reg‚ seal
  • Ergomonically Correct Plastic T Handle
  • Lightweight aluminum body and cap
  • Color coded gauge protector
  • Contents gauge on the front and the flow gauge on the top
  • Compact and lightweight
  • CGA connection: Yoke (870) style
  • 4-1/4" long
  • Weight: 7.8oz

EasyFial Regulator User Manual

What to buy with Precision Medical Oxygen Regulator?


How to Operate Oxygen Regulator?

  • Check cylinder valve to be sure it is not bent or damaged. A damaged valve could leak or fail, or it may not make a tight connection when cylinder is placed into use. 
  • Make sure the Regulator and cylinder valve are free of oil, grease or other contaminants.
  • Before installing Regulator, crack cylinder valve by opening the valve slightly and closing to remove any foreign particles.
  • Be sure Regulator is in the OFF position. Align OFF with the Indicating Pointer.

A. For CGA 870 connection (Yoke):
  • Be sure the high pressure inlet port has a Yoke Seal. 
  • Attach Regulator to the oxygen cylinder post valve and align index pins with mating holes.
  • Hand tighten T-handle. 

B. For CGA 540 connection (Nut and Nipple):
  • Attach the Regulator to the oxygen cylinder valve and tighten with wrench. 
  • Position the Regulator so the cylinder valve opening is pointing away from the user and any other person(s). 
  • Slowly open cylinder valve counter clockwise, until completely open. 
  • Turn dial until Indicating Pointer is pointing to the prescribed flow. 
  • Continue procedure as prescribed by your healthcare professional. 
Note:
Precision Medical, Inc. strongly recommends the use of kink proof patient tubing. When the Dial Regulator is not in use, turn dial until the Indicating Pointer is pointing to OFF and close cylinder valve.
To remove Dial Regulator from cylinder:
  1. Completely close oxygen cylinder valve.
  2. Turn dial until the Indicating Pointer is pointing to OFF".
  3. Slowly loosen T-handle or Nut and remove Regulator.

How to clean Precision Medical Regulator?

  • Disconnect all connections before cleaning.
  • Clean exterior surfaces of the Dial Regulator with a cloth dampened with disinfectant with Sporicidin R or equivalent.
  • Wipe dry with a clean cloth.
  • Store the Regulator in a clean area free from grease oil and other sources of contamination.

Precaution
  • Do not use cleaning solutions.
  • Do not attempt to repair the Dial Regulator. All repairs must be performed by Precision Medical, Inc.

EasyDial Reg Oxygen Regulator Specification

ParticularsSpecifications
Accuracy±10% of indicated setting @ 70°F (21°C)
Transport and Storage Temperature Range-4°F (-20°C) to 140°F (60°C)
Inlet Pressure Range300 psi to 3000 psi (2068 to 20684 kPa)
Ignition and Fault Tolerancemeets ASTM G175-03


Flow RangePosition Increments
0 lpm to 4 lpmOff, 1/32, 1/16, 1/8, 1/4, 1/2, 3/4, 1, 1-1/2, 2, 3 and 4
0 lpm to 8 lpmOff, 0.25, 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6 and 8
0 lpm to 15 lpmOff, 0.5, 1, 1.5, 2, 3, 4, 5, 6, 8, 10 and 15
0 lpm to 25 lpmOff, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15 and 25

Oxygen Regulator Warranty

5 year limited warranty

EasyDial Reg Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 

SubmitCancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close

{{VideoGallery[0].VideoName}}

More Oxygen Regulators

${{ x.OurPrice | currency: "" : 2}}

Articles & news

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Questions & Answers



Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image
O2 reg 2 to 6 ml per min continuous, and 6 to 10 pulse.
Danny P Russell - 4/12/2020 1:29:41 AM
answer image
We apologize for we could not understand what you were trying to ask. Could you please reframe your query?
Customer Care - 4/15/2020 8:52:18 AM
question image
Does this valve operate on pulse or is it constant flow
Gary Borst - 3/26/2019 10:01:13 AM
answer image
"Precision Medical EasyDial Reg Oxygen Regulator is a continuous flow Easy Dial Regulator,"
Customer Care - 5/10/2019 5:29:28 AM
question image
My husband is on 6 liter of oxygen and the doctors have just up the liters to 8 or 10. Is the regulator good for pulse at 8 or more.
Jean - 4/20/2016 2:29:26 PM
answer image
Thank you for reaching out to us. Yes, it is available in 0 - 8 L/min, 0 - 15 L/min and 0 - 25 L/min.
Customer Care - 4/21/2016 1:30:33 AM
question image
will these work on a invacare homefill tanks ,and i have to have a continous flow rate a 2
jeff - 12/17/2015 6:53:41 PM
answer image
Thank you for reaching out to us. The Invacare HomeFill tanks are only for use with the HomeFill oxygen compressor.
Customer Care - 12/29/2015 1:59:05 AM
question image
which 1 can i use for a setting of continues flow 2, also do they work on invacare homefill tanks D size 
jeff - 12/16/2015 5:15:57 PM
answer image
Thank you for reaching out to us. The Invacare HomeFill tanks are only for use with the HomeFill oxygen compressor.
Customer Care - 12/29/2015 1:58:39 AM