Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber
Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber

Brand/Manufacturer: MONAGHAN MEDICAL
Save

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber improves the delivery of medications from Metered-Dose Inhaler (MDI) canisters. It reduces the coordination required between canister activation and inhalation, thereby making it easier for the patients to use the MDI correctly.

AeroChamber Plus Z STAT aVHC Highlights:

  • Reduces drug deposition to the mouth and throat
  • Eliminates unpleasant taste of medication or hoarseness
  • Assures consistent dose of medication
  • Suitable for adults and young adults
  • Reusable and can be used for 12 months
  • Single patient use

Item #DescPkgRewardPrice 
79750 With Flowsignal Whistle Each $0.08
$15.99
$8.32
79750 With Flowsignal Whistle 5/Pack $0.42
$79.99
$41.60
88710 With Small ComfortSeal Mask Each $0.20
$39.85
$20.09
88710 With Small ComfortSeal Mask 5/Pack $0.99
$150.99
$98.99
78710 With Medium ComfortSeal Mask Each $0.22
$39.85
$21.99
78710 With Medium ComfortSeal Mask 5/Pack $0.99
$150.99
$98.99
80710 With Large ComfortSeal Mask Each $0.22
$42.56
$21.99
80710 With Large ComfortSeal Mask 10/Pack $2.20
$412.56
$219.90

Monaghan AeroChamber Plus Z STAT aVHC Features

  • Original valved holding chamber has evolved into the AeroChamber Plus Z STAT aVHC to optimally interface with improved MDI aerosol formulations and activities
  • Offers a more effective way of getting the inhaled mist into the system
  • Provides consistent and high performance aerosol drug delivery
  • Combines patient-centric design that assures consistent dose of medication substantially equivalent to the MDI dose
  • Designed to respond to shallow and low volume breathing patterns
  • Very useful for people with asthma as it ensures that one get more of the inhaled asthma medicine to lungs for relief during an asthma attack
  • Not made with BPA, Natural Rubber Latex, Phthalates, Lead or PVC
  • Anti-static, can be used directly out of package
  • Easy to clean - dishwasher safe

Design Features of Monaghan Inhaler Spacer:

  • Clear chamber for easy visualization of proper activation of the MDI
  • Aerodynamic chamber design with innovative valve system separates and filters out coarse aerosol particles
  • Proprietary valve baffle design increases aerosol suspension time to assist dose assurance of MDI medication
  • One-way valve prevents patients from exhaling into the chamber so that the remaining medication is available for the next breath
  • Delivers 22% more medication than the original AeroChamber
  • Universal MDI adapter is compatible with all commonly prescribed MDIs
  • Durable holding chamber is made of a unique, flexible and shatterproof plastic
  • Optional ComfortSeal Mask, made of medical grade silicone, has a snug fit with secure seal, limiting entrainment of ambient air and maximizing drug delivery even at low inspiratory flows
  • Optional FlowSignal whistle alerts the patient to excessive flow rates

How does AeroChamber Z STAT Inhaler work?

AeroChamber is a spacer device that makes it easier to get more medication from an inhaler into the lungs. It can be used all the time, or if asthma is playing up a bit. AeroChamber inhaler maximizes delivery of medication to the lungs by separating the small medication particles from large. As the patient inhales, the smaller particles float out of the one-way valve of the chamber into the respiratory tract where they easily reach areas of the lungs that need it most. The Monaghan inhaler spacer holds any remaining small particles not inhaled the first time, which allows the patient to take more than one breath per puff of medicine administered. This is especially helpful to those who cannot achieve a high peak expiratory flow (PEF), and assures the maximum amount of prescribed medicine gets into the lungs for optimum benefit.

AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber

  • EZ Flow Exhalation Valve: Minimizes re-breathing and directs exhaled flow away from the face of the patient.
  • Anti-Static Chamber: Anti-static polymer chamber minimizes static charge which maximizes performance with pMDI formulations.
  • Low Resistance Inhalation Valve: Lower resistance valve requires less effort to open by low flow patients.
  • Universal Backpiece: Fits all commonly prescribed Metered Dose Inhalers.
  • FlowSignal Whistle: Optional FlowSignal whistle alerts patients to breathe slowly.

How to use Aerochamber Plus Z Stat aVHC?

  1. Carefully examine Aerochamber Plus Z STAT Anti-Static Valved Holding Chamber for damage, missing parts or foreign objects.
  2. Shake the MDI immediately before each use.
  3. Insert the MDI into the backpiece of the chamber.
  4. Apply mask to face or put mouthpiece into mouth and ensure there is an effective mask/face seal.
  5. While maintaining an effective mask/face seal, the patient should exhale through the mask.
  6. Depress inhaler (MDI) at the beginning of slow deep inhalation.
  7. Maintain the effective mask/face seal and ensure an additional 5-6 breaths are taken through the chamber before administering another puff of medication.
  8. If you are using the model with Flowsignal whistle and you hear a whistle sound then slow down inhalation.
  9. Wait 30 seconds before repeating steps 4 to 8 as prescribed.

Cleaning the Aerochamber Inhaler:

  • Hold the rubber end and twist the chamber to remove the back piece.
  • Soak both parts for 15 minutes in luke warm water with liquid detergent. Agitate gently.
  • Rinse parts in clean water. Shake out excess water.
  • You may also clean the chamber on the top rack of your dishwasher. Secure it so that it is in a vertical position. It is not recommended that you boil the chamber.
  • If concerned about potential for contact dermatitis, rinse facemask or mouthpiece in water.
  • Do not rub dry. Let air dry in vertical position.
  • Replace back piece when unit is completely dry and ready for use

Cautions:
  • Read all instructions before use.
  • Aerochamber inhaler should be replaced if valves are damaged or missing.
  • Do not leave the product unattended with children.
  • If unsure on how to use this product, talk to your physician, pharmacist or health care provider. This is a medical device, not a toy.
  • Do not disassemble the product beyond what is recommended for cleaning, or damage may result.

AeroChamber Plus Z STAT Instruction Manual

Customer Reviews

Questions & Answers


 
 

Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image

How long is an aero Chamber Plus Z Stat good for?


sandra lerner - 2/15/2017 4:01:30 PM
facebooktwittergplus
answer image
Aerochamber Plus Z STAT Anti-Static Valved Holding Chamber is designed for 12 months of use at home, clinic, or hospital environment.
Customer Care - 2/16/2017 2:04:09 AM
question image

How to clean the

aero Chamber Plus Z Stat?

Jackie Homan - 11/17/2016 12:19:15 PM
facebooktwittergplus
answer image
Cleaning instructions:
  • Remove back piece only 
  • Soak both parts for 15 minutes in luke warm water with liquid detergent
  • Agitate gently
  • If concerned about potential for contact dermatitis, rinse facemask or mouthpiece in water
  • Shake out excess water
  • Do not rub dry
  • Let air dry in vertical position
  • Replace back piece when unit is completely dry and ready for use
Customer Care - 11/18/2016 3:00:04 AM
question image
What are the indications for usage?
Antoinette - 9/25/2014 12:21:08 AM
facebooktwittergplus
answer image
The AeroChamber Plus Z STAT anti-static Valved Holding Chamber (“aVHC”) with Flowsignal Whistle is intended to be used by patients who are under the care or treatment of a licensed health care professional or physician. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers, prescribed by a physician or health care professional. The intended environments for use include the home, hospitals and clinics.
Customer Care - 9/29/2014 12:14:02 AM
question image
Are there any precautions to be taken?
Robin - 9/18/2014 12:28:59 AM
facebooktwittergplus
answer image
  • Product should be replaced if valves are damaged or missing.
  • Do not leave the AeroChamber Plus Z STAT aVHC unattended with children.
  • If unsure on how to use this product, talk to your physician, pharmacist or healthcare provider.
  • Do not disassemble the product beyond what is recommended for cleaning, or damage may result.
  • Storage and operating range 5˚C - 40˚C (41˚ F - 104˚F) at 15 to 95% relative humidity.
Customer Care - 9/19/2014 12:13:00 AM
question image
How do I clean it?
Susan - 9/12/2014 12:40:25 AM
facebooktwittergplus
answer image
The AeroChamber Plus Z STAT aVHC should be cleaned weekly following the instructions provided below.
  • Remove back piece only. Do not remove mask or tamper with valves during cleaning.
  • Soak both parts for 15 minutes in lukewarm water with liquid detergent. Agitate gently.
  • Rinse in clean water.
  • Shake out excess water. Do not rub dry.
  • Let air dry in vertical position.
  • Replace back piece when unit is completely dry and ready for use.
Customer Care - 9/13/2014 12:07:17 AM
question image
How do I use it?
Stacia - 8/31/2014 11:58:49 PM
facebooktwittergplus
answer image
  • Carefully examine the product for damage, missing parts or foreign objects. Any foreign objects should be removed.
  • Before use, make sure that instructions supplied with inhaler (MDI) have been read. Remove cap(s).
  • Shake the inhaler (MDI) well immediately before each use. Insert the inhaler (MDI) into the back piece of the chamber.
  • Apply mask to face and ensure there is an effective mask/face seal. While maintaining an effective mask/face seal the patient should exhale through the mask.
  • Depress inhaler (MDI) at beginning of slow deep inhalation. Hold breath as long as possible, up to 10 seconds before breathing out. If patient has difficulty with slow deep breaths, an alternative is to keep face tight on mask and breathe slowly 2-3 times after depressing inhaler (MDI). Administer one (1) puff at a time.
  • Slow down inhalation if you hear the Flowsignal Whistle sound.
  • Follow instructions supplied with the inhaler (MDI) on amount of time to wait before repeating above steps.
Customer Care - 9/1/2014 7:44:51 AM
question image
can you use this AeroChamber with a pediatric mask
Shelly - 8/20/2014 3:21:57 PM
facebooktwittergplus
answer image
This product has chamber with Mask already assembled to the chamber. They come as one unit. If your device does not already have a mask attached I cannot recommend using other mask with the chamber.
Customer Care - 8/22/2014 6:41:06 AM
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close