Drive PureFill Oxygen Compressor System

Drive PureFill Oxygen Compressor System

Brand/Manufacturer: DRIVE MEDICAL
Authorized Retailer Badge
  • Prescription required

Drive PureFill Oxygen Compressor System is an electrically operated unit which fills pressurized cylinders with concentrated oxygen produced by an oxygen concentrator. It is recommended to be used with the oxygen sensing Drive Pure Oxygen Concentrator. It is isolated from the supply mains via an appliance coupler. This is the detachable cord that comes with the unit. Through oxygen tubing, it is attached to the Pure Concentrator which creates concentrated oxygen from room air.

Drive PureFill Compressor Highlights

  • Designed to provide an unlimited oxygen 
  • Eliminates need to install conserver on cylinder 
  • Light weight and quiet operation

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

PayPal Credits 6 Payments: Starts From $360.00

Item #DescPkg Price 
PF1100 23"L x 8"H x 12"D Each $216.00
$2,599.99
$2,159.99

Oxygen Compressor Features

  • Drive PureFill Oxygen Compressor System is isolated from the supply mains via an appliance coupler which is a detachable cord
  • Patients may use up to 3 LPM from their concentrator while it is in operation
  • Designed to seamlessly integrate with the Pure Oxygen Concentrator
  • Compatible with the following devices :
    Concentrators
    Integrated Conserving Devices
    •  May be supplied with an INT-812 Bonsai Velocity oxygen conserver
    •  INT-812 is an OM-812 oxygen conserver, integrated with a 2000 PSI (135 bar) aluminum oxygen cylinder which has a compatible oxygen fill port valve for it
    Cylinder Types and Sizes
    •  2000 PSI aluminum oxygen cylinder with an appropriate fill port valve
    •  M4 (A), M6(B), ML6(B), M9(C), and D sized cylinders with the appropriate fill port valve
    Conservers and Regulators
    • It is recommended that Drive conservers or regulators are used with an oxygen cylinder filled by it, however any conserver or regulator may be used with oxygen cylinder
  • Click Here To View User Guide
Note: Image shown with concentrator which is not included.

What To Buy with Drive Compressor System?


How to Use PureFill Oxygen Compressor?

  • Indications for Use
    •  The PureFill Oxygen Compressor is indicated to supply pressurized oxygen to fill gas cylinders for the patients personal ambulatory use
    •  The device is not intended to be life supporting or life sustaining
    •  Environment of use: Sub-acute care facilities and home settings
    •  This device is not, intended to be life supporting or life sustaining, nor is the combination of this device and an oxygen concentrator
  • Warnings And Cautions
    •  To avoid the risk of electric shock, this equipment must only be connected to the supply mains with protective earth
    •  It is equipped with a detachable cord. Do not position the equipment so that it is difficult to operate this disconnection device
    •  If while using the system the user experience any discomfort or signs of any unusual physical symptoms, contact physician immediately
    •  Oxygen can promote rapid burning when exposed to an open flame. Do not allow any smoking objects or open flames near this unit
    •  Do not use any oil, grease, or petroleum-based products on or near this unit
    •  Do not smoke while the device is in use
    •  Protect the device against the spillage of fluids on or around it
    •  Do not place drinks on it. Do not allow fluids to come in contact with the device. If fluids do come in contact with the device, contact service representative
    •  Do not set any objects on, or allow to be draped over, the PureFill system as they may block air flow into the device. Place the unit in a ventilated location with the sides and rear two feet away from any object
    •  Do not allow minors or children to operate it
    •  Do not allow unsupervised children to play on or near the device
    •  To prevent an accidental tip over, do not attempt to move the PureFill when it is connected to a cylinder
    •  Do not use it if either the plug or power cord is damaged
    •  Do not use an extension cord with it
    • Do not connect the PureFill System to an electrical outlet controlled by a wall switch or ground fault interrupter
    •  Make sure there is no other high power device such as a TV, stereo, computer, radio transmitter, space heater, hair dryer, refrigerator, microwave oven, electrical range, or other large appliance connected to this outlet
    •  Electrical shock hazard: Do not remove the cabinet of the PureFill Station. The removal of the cabinet should only be performed by Drive Medical or a trained representative
    •  Disconnect the power cord from the electrical outlet before cleaning the housing of thePureFill Station
    •  Do not fill cylinders that have not been tested in the past 5 years. Otherwise, serious personal injury may result. Contact dealer for replacement
    •  Never use tools of any kind to disconnect the cylinder from the PureFill system. Otherwise,severe injury and/or damage may occur
    •  Do not drop oxygen cylinders. Use two hands when handling/transporting oxygen cylinders.Otherwise, injury or damage may occur
    •  Do not use a liquid leak detector to test for leaks
    •  No modification of this equipment is permitted
  • Cleaning and Maintenance
    Before cleaning the PureFill system, be sure the Power Button is Off (O) and the device is no longer connected to a wall outlet
    •  Use a damp cloth with a mild household detergent to wipe down the outside of the PureFill
    • Avoid using excessive quantities of water
    •  Use a dry cloth to wipe dry

Drive Purefill Compressor System

ParticularsSpecifications
Input Pressure Required14-30 PSIG
Input Flow RequiredGreater than or equal to 2 L/min
Input O2% RequiredGreater than 90%
Noise55 dBA
Width23" (58 cm)
Height8" (20 cm)
Depth12" (30 cm)
Weight35 lbs (13.6kg)
Typical Fill Times
M4 (A) Cylinder (113L)
M6 (B) Cylinder (170L)
M9 (C) Cylinder (246L)
D Cylinder (425L)

52mins with the Drive Pure Oxygen Concentrator
80mins with the Drive Pure Oxygen Concentrator
124mins with the Drive Pure Oxygen Concentrator
5hrs with the Drive Pure Oxygen Concentrator
Power ConsumptionApprox. 110W average
No AP/APGNot Suitable for use in the presence of a flammable anesthetic mixture
Electrical115 VAC – 60Hz – 1.5A – Class I Equipment
PlacementNo closer than 24 inches from any wall, furniture, or draperies to assure sufficient air flow. Avoid deep pile carpets and heaters, radiators or hot air registers. Floor location, or flat surface such as a table
Duty CycleContinuous
EnvironmentSmoke and soot-free. No confined spaces (Example: No closets)
Operating Temperature Range41°F to 104°F (5°F to 40°C)
Operating Relative Humidity Range15% to 93%
Transport and Storage Temperature Range-13°F to 158°F (-25°F to 70°C)
Transport and Storage Relative Humidity RangeUp to 93%
Ingress of LiquidIP21
Altitude700hPa to 1060hPa
Expected Service Life5 Years
MaintenanceThe PureFill Oxygen Compressor requires no periodic maintenance. There is a bacteria filter located inside the PureFill , which can be changed at the provider;s discretion.
Warranty3 years or 3000hr

Compressor System Warranty

3 years or 3000hr

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 

SubmitCancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close

{{VideoGallery[0].VideoName}}

Other Devilbiss Concentrator

{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}

Articles & news

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Questions & Answers



Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.