Prius Healthcare Rhythm Turn Mattress System

Brand/Manufacturer: PRIUS HEALTHCARE USA
For Questions, Please Call...
Item # Desc Pkg Price
PHR-RHYT36 Rhythm Turn Mattress System, 36 Inch $89.97
$3,499.99
$2,999.00
PHR-RHYT42 Rhythm Turn Mattress System, 42 Inch $104.97
$3,999.99
$3,499.00
PHR-RHYT48 Rhythm Turn Mattress System, 48 Inch $107.97
$4,299.99
$3,599.00

Prius Healthcare Rhythm Turn Mattress System is a low-air-loss (LAL) pressure relief mattress system that provides continuous lateral rotation therapy, which helps mobilize secretions and other body fluids during pulmonary treatment related to immobility. It provides continuous lateral rotation therapy in two different degrees (20 degrees and 40 degrees), which gently turns the patient from side to side to significantly lower the risk of infection, pneumonia and other pulmonary complications

Benefits of Prius Healthcare Rhythm Turn Mattress System

  • Low slip base cover to keep the mattress in place
  • Effective micro low air
  • Nylon woven fabric
  • CPR for quick deflation
  • Cable management for patient safety

Prius Healthcare Rhythm Turn Mattress System Features

  • 8 Inch air cell mattress replacement
  • Low air loss therapy 20 and 40 degree lateral rotation with side perimeter and static therapy
  • Auto Firm provides immediate firm surface
  • High vapor permeable and quilted nylon cover
  • 2 Inch convoluted foam base 
  • Integrated glide sheet to base cover for easy transferring
  • Visual and audio alarm for low pressure and power failure with alarm mute function
  • Keypad lock out function
  • 10 Digital comfort setting
  • Modularized design for air mattress
  • Integrated power cable retainer
  • Quick CPR deflation within 20 seconds

What to buy with Rhythm Turn Mattress?


How to use Prius Healthcare Rhythm Turn Mattress System?

  1. Remove the existing mattress from the bed frame
  2. Replace the standard mattress with Low Air Loss Turning Mattress Replacement system and make sure the mattress is positioned so the air tube is at the foot of the bed
  3. Secure the straps beneath the mattress to the bed frame
  4. Hang the Master Control Unit on the footboard of the bed frame. Attach the air tube connector to port on the left panel of the Master Control Unit. Be careful on the color matching between the connectors and socket. (black connectors to black socket, red connector to red socket)
  5. Make sure the air hoses are not kinked under the mattress. (Could be verified by simple visual check) For detail Air hose connection please refer Explode Diagram
  6. Zip the low shear top cover to the mattress. The top cover should be loosely fit to the mattress
  7. Carefully plug power cord into a properly grounded power source. Turn on the master mechanical power switch on the right side panel. The STANDBY LED should illuminates.
  8. Push the STANDBY/OPERATE button of the front panel. The OPERATE LED should now be lighted up and the Master Control Unit should now start to spin
  9. Push the AUTO FIRM button for fast inflation. Allow 4 ~ 7 minutes for full inflation. After the mattress is fully inflated, the caregiver can now transfer the patient on to the mattress. Push the AUTO FIRM again to release the fast inflation mode. (Note: The mattress can be inflated with patient lying on top)
  10. Static Function: Push the static button and adjust the Contort Control by pressing the SOFT/FIRM button to achieve the maximum patient comfort. On this mode the system provides True Low Air Loss therapy. Perform a hand check by placing hand under the patient buttocks between cells and foam. The patient should have at least 4 cm of clearance between the buttocks and the bottom of the mattress.
  11. Turning time can be adjusted by the CYCLE button. The time can be adjusted from 3 minutes to 95 minutes. (When Static Function is selected, the timing window would not show any digits)
  12. The Master Control Unit is equipped with power failure alarm. With this function enabled, the Control unit generates a horn sound to signal to caregiver that main power failure. The alarm can be disabled by pushing the Alarm Reset Button on the front panel
  13. LOCK-OUT: The Master Control Unit is also equipped with a manual locking-out function. All function keys will be automatically disabled if the LOCK –OUT button has not been activated. When lock-out has been engaged, the “LOCK OUT” button will illuminate. UNLOCKING Unlocking the control panel is easy. Simply press the “LOCK OUT” button on the control panel for 3-5 seconds or recycle the power by turning off and on the main power switch
  14. 20 degrees turning function can be activated by pressing the “TURN” and select desire turning therapy. “LEFT TURN” allows the mattress to turn to left and back to horizontal. “RIGHT TURN” would have the same effect but turning to the right. The “FULL TURN” allows for full function of turning to left and right and should always activate with timer setting. The timer can be set by “CYCLE” button
  15. 40 degrees turning function can be activated by pressing the “BT” button and follow the operation instruction on step 14.

How to clean Rhythm turn mattress System?

  • The Mattress
    The mattress should be cleaned weekly using a damp soft cloth and mild detergent. If top sheet (Top cover) or base (Bottom cover) becomes overly soiled, put on clean gloves, plastic gown and eye protection before removing top sheet or base and dispose of according to standard in function control procedures. Replace with clean covers.
  • The Master Control Unit
    The master control unit should also be cleaned weekly using a damp soft cloth and mild detergent. The blower casing is manufactured from ABS plastic and if the case is soiled the blower can be wiped down with a sodium hypochlorite solution to dilution of 1000ppm or any EPA- approved hospital grade disinfectant. (NOTE: Do not use phenol base cleaning solution.) The air filter should also be cleaned and checked as often as possible at a minimum of every six months. Air Filter can be removed by pinching center of the filter and pulling outward from the back of the Therapy control unit.

Storage and Care
  • Master Control Unit
    • Check the power cord and plug for abrasions or excessive wear
    • Plug in the unit and verify air flows from the units hose connection ports
    • Place in plastic bag for storage
  • Mattress Replacement
    • Check the air manifold for kinks or breaks and replace if necessary.
    • Pull out the CPR plug at the head of the mattress and disconnect the air feed tubes. All the air will now be expelled. Starting at the head end, the mattress can now be rolled. Use the base mounted straps for containment
    • Place in plastic bag of storage.
Prius Healthcare Rhythm Turn Mattress System User manual

Rhythm Turn Mattress System Specifications

Control SpecificationsValues
Dimension(L) 17.7" x (W) 6.8" x (H)10.8"
Weight13.8 lbs
Cycle Time3~95 min
Min Operating Pressure10 +/- 3mmHg
Max Operating Pressure61 +/- 4mmHg
Flow-rateN/A
Rated VoltageAC 110-120V
Rated Frequency60 Hz
Fuse Rating5A 250V
Max Current5A
ClassificationClass I, Type BF
Operation Temperature15°C (59°F)~35°C (95°F)
Operation Humidity30% ~ 75%
Matterss SpecificationValues
Dimensions(L)36" x (W)80" x (H)10"
Weight37.4 lbs
Cell Number18 cells
Cells MaterialNylon Coated with PU
Cover TypeZipper Cover
Cover MaterialNylon Woven fabric w/PU coating finish
Base MaterialWoven Polyester fabric w/PVC backing

Rhythm Turn Mattress Warranty

Up to 12 months from the date of delivery

Customer Reviews

+=
Question

ItemName - now     09/19/2021

ItemQuestion
  Your question will show here once it will get approved.
Answer

UserName - now     09/19/2021

UserAnswer
  Your Answer will show here once it will get approved.

{{x.Heading}}

{{x.ShortDescription}} ...

What is HPFY’s return policy?

Customer satisfaction is our top priority. We stand behind our products. If the merchandise you received is defective or not what you expected it to be, and you wish to return the item, please submit a return request in the My Account section of our website, contact our Customer Service department at (866) 316-0162 / (203) 616-2850 or email us.

  1. Merchandise must be returned within 30 days of the receipt of your order. Returns are not accepted after 30 days.
  2. Items (including parts and accessories) must be returned in new, unused, and resalable condition in its original packaging.
  3. Before returning any product, the buyer must obtain a Return Authorization Number (RA#) from a customer service representative. With your RA# you will receive a prepaid return shipping label.
  4. Orders returned without obtaining an RA# will be entitled to receive only "In-Store Credit" that can be used towards future purchases.
  5. Return orders are subject to a 20% restocking fees.
  6. All custom orders and hygienic items are non-returnable. Refer to the “Non-Returnable Items” section for further details.
  7. Returns will be reviewed and inspected before issuing credit. Please allow 3 to 4 weeks for processing. The credit will be applied to your original method of payment.
  8. If the return is the result of a defective product or shipping error, we will refund the entire purchase amount and return shipping costs.

Which products are Non-Returnable?

Due to the hygienic nature of some items, they are non-returnable. The items listed below are non-returnable:

  1. All hygienic items.
  2. Opened personal care items.
  3. Anything opened, used, or tried on.
  4. All customized items.
  5. Besides these, items that have the “non-returnable” phrase on the website.

We reserve the right to make adjustments due to errors, changing market conditions, product discontinuation or typographical errors in advertisements. Images on the site may not always reflect the actual product. Footrests or leg-rests are not included with wheelchairs unless specified.

How do I receive a return authorization number?

You can submit a return request by logging into your account. You will receive the Return Authorization Number (RA#) details in the email within 2-3 business days.

  • Login to your account
  • Go to “order history”
  • Click on “return order”
  • Fill out the return form and Submit it

If you do not have an email address, we will make other accommodations for RA# Details. Write the RA# on your label affixed to your package prior to shipment.

How long does it take to receive a refund?

Please allow 3 to 4 weeks to process the returns. Once the item is received, and inspected, your refund will be processed and automatically applied to your credit card or original method of payment.

Is there any Restocking Fees?

  1. 20% restocking fees will be applied.
  2. Outbound shipping cost is non-refundable.
  3. For orders that qualified for free shipping, $8.99 will be deducted from the refund if the product is returned.

Other Pressure Therapy Mattresses

{{'Buy ' + x.Name}}
{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}
Please enter your and your friend's email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
Submit Cancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close