Prodigy AutoCode Blood Glucose Meter is a small, portable, and easy-to-use device that allows people with diabetes to keep track of their blood sugar levels at home or on the go. This device has an automatic coding system which eliminates the need for manual coding of test strips. This means that the user simply inserts the test strip into the meter, and the device automatically recognizes and calibrates the strip, ensuring accurate and consistent results every time.

What does Prodigy Autocode Meter Include?

  • Prodigy Autocode Meter: This handheld device measures the glucose level in the blood.
  • Lancets: A lancet is a small, sharp needle used to obtain a drop of blood for testing.
  • Test strips: are the small, plastic strips the blood is collected on for testing. They contain an electrochemical biosensor that measures the glucose level in the blood.
  • Control solution: This is used to check the accuracy of the meter and test strips.
  • Batteries: The meter is powered by batteries, which are included with the device.
  • Carrying case: A compact carrying case is included to store and transport the meter and other components.
  • User manual: A detailed user manual is included to help the user get started with the device and understand how to use it properly.

$24.47

Total: $19.57

Earn $0.59 in HPFY rewards

Prodigy Diabetes Care Blood Glucose Meter Features

  • No coding required
  • 7 second results
  • 0.7 microliter blood sample from fingertip
  • Stores up to 450 results with date and time, 7, 14 and 28 days averaging
  • Speaks in 4 Languages: English, Spanish, French & Arabic
  • Approved for Alternate Site Testing (AST)
  • Standard USB port to easily download test results

Prodigy Autocode Blood Glucose Monitoring System Parts

  1. Lancing device cover
  2. Depth penetration
  3. Trigger button
  4. Lancet needle cover
  5. Lancet
  6. Lancet carrier
  7. Lancet ejector
  8. Loading barrel
Prodigy AutoCode Blood Glucose Meter
 

What is the purpose of using this Glucose monitor?

  • Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh.
  • The system is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes. It is an at-home aid to monitor the effectiveness of diabetes control.
  • It should not be used for diagnosing or screening diabetes or neonatal use.

Frequently Bought Together


How to use Prodigy AutoCode Blood Glucose Meter?

  1. Insert Test Strip Insert the test strip, and the meter will power on automatically. No Coding is Required.
  2. Apply the Blood Sample When “ “ appears, apply the blood. The meter will beep.
  3. Hear and see test results.
Prodigy AutoCode Blood Glucose MeterProdigy AutoCode Blood Glucose Meter
 

How to setup the device?

  1. Insert the Batteries Open the battery cover located on the back of the meter. Insert two (2) AAA Alkaline batteries and align them properly. The meter will turn on and enter Setting Mode.
  2. Enter Setting Mode If your meter is off, press the “SET” button located in the battery compartment. The meter will enter setting mode.
  3. Select Language The language option appears first with “L-1” on the LCD. “L-1” indicates the default language (English); “L-2” indicates the second language (Spanish); “L-3” indicates the third language (French); and “L-4.” indicates the fourth language (Arabic). Press the “M” button to select a language. With the correct language selected, press the “SET” button and a number will appear.
  4. Set the Volume Level
    • Numbers 1 to 3 indicate the speaker volume from low to high. If the speaker function is set on one of these levels, “ ” will be present on display during testing.
    • Number 0 indicates that the speaking function is turned off.
  5. Set the Year Press and release the “M” button to advance the year. With the correct year on the display, press the “SET” button. The date will then appear on the display with the month segment flashing.
  6. Set the Month Press and release the “M” button to advance the month. With the correct month on the display, press the “SET” button. The date segment will start flashing.
  7. Set the Date Press and release the “M” button to advance the date. With the correct date on the display, press the “SET” button. The time will appear on the display with the hour segment flashing.
  8. Set the Hour Press and release the “M” button to advance the hour. With the correct hour on the display, press the “SET” button. The minutes segment will start flashing.
  9. Set the Minutes Press and release the “M” button to advance the minutes. With the correct minutes on display, press the “SET” button, and then the current unit of measurement will start flashing.
  10. Select Unit of Measurement Press and hold the “M” button for four (4) seconds until the unit of measurement you are choosing appears on display. To skip this step, press the “SET” button. Your meter can display test results in milligrams per deciliter (mg/dL) or millimoles per liter (mmoL/L).
    • The mg/dL unit is standard in the United States.
    • The mmol/L unit is standard in Canada.
    • The Prodigy AutoCode meter is set by default to read glucose values in mg/dL unless changed by the user.
    • Reading glucose values in the incorrect units may cause serious problems, such as improper doses of medication.
  11. Delete Memory When the “dEL” and flashing “M” symbols appear on display, you can choose to clear the memory. If you do not want to clear the memory, press the “SET” button to skip this step.

Prodigy AutoCode User Guides


Prodigy Glucose Meter Specifications

Dimensions 3.77 in. (L) x 2.11 in. (W) x 0.86 in. (H)
Weight 2.78 oz with batteries (79g)
Power Source Two (2) 1.5 Volt AAA Alkaline Batteries
Battery Life Over 1,000 tests
Display LCD
Memory 450 test results with date and time
Operating Condition 50°F–104°F (10°C–40°C),/ 10-85% R.H. (non-condensing)
External Output USB Data Port
Storage/Transportation Condition 39.2°F –104°F (4°C–40°C), 10-85% R.H.
Measurement Units mg/dL or mmol/L
Measurement Range 20– 600 mg/dL (1.1–33.3 mmol/L)

 

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Prodigy AutoCode Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close