BD Insyte Autoguard Winged Shielded IV Catheters
BD Insyte Autoguard  Winged Shielded IV Catheters

BD Insyte Autoguard Winged Shielded IV Catheters

Brand/Manufacturer: BECTON DICKINSON
Save
  • Latex Free

BD Insyte Autoguard Winged Shielded IV Catheter is designed to reduce needle stick injuries. It is made of BD Vialon biomaterial and features stabilizing wings which provide a large surface area for taping down the catheter, thereby improving catheter securement. Instaflash Needle Technology improves first-stick success and reduces painful hit-and-miss insertions. The unique Push-Button Shielding mechanism helps release the spring and allow the needle and flash chamber to quickly retract into the safety barrel, reducing the risk of accidental needle-stick injuries. The clinician can maintain control of the process by deciding when to activate the push-button shielding mechanism.

Item #DescPkgRewardPrice 
381512 24G x 0.75" (0.7mm x 19mm) Each $0.04
$5.50
$3.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack $1.60
$220.65
$159.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack, 4PK/Case $5.70
$808.70
$569.99
381523 22G x 1" (0.9mm x 25mm) Each $0.04
$5.50
$3.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack $1.60
$220.65
$159.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack, 4PK/Case $5.70
$808.70
$569.99
381533 20G x 1" (1.1mm x 25mm) Each $0.04
$5.50
$3.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack $1.64
$227.87
$163.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack, 4PK/Case $5.80
$839.99
$579.99
381534 20G x 1.16" (1.1mm x 30mm) Each $0.04
$5.50
$3.99
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack $1.64
$227.87
$163.99
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack, 4PK/Case $5.80
$839.99
$579.99
381544 18G x 1.16" (1.3mm x 30mm) Each $0.04
$5.50
$3.99
381544 18G x 1.16" (1.3mm x 30mm) 50/Pack $1.64
$227.87
$163.99
381544 18G x 1.16" (1.3mm x 30mm) 50/Pack, 4PK/Case $5.80
$839.99
$579.99

BD Insyte Autoguard Shielded IV Catheters

Product Highlights:

  • Incorporates advanced safety features to provide additional safety to the clinician which facilitates efficient and effective quality care
  • BD Insyte is ideal for emergency, operating, labor and delivery room
  • Reduces hit-and-miss insertion attempts by immediately confirming vessel entry, enabling the user to stay focused on the insertion site
  • This Vascular Access Device allows the user to see the blood return within the catheter before it reaches the flash chamber
  • Provides added confidence when accessing the vein in patients with compromised veins where first-stick success is of special importance
  • Superior tip integrity, ultra-smooth micro-surface and exclusive lubrication process enable for easiest insertion possible
  • Easy to insert, while providing longer dwell times with improved patient outcomes
  • Easier to place and advance on a wider cross-section of patients
  • Reduces the incidence of mechanical phlebitis, a major complication of IV therapy by reducing the chances of irritation to the vessel wall
  • Does not contain elasticized PVC or natural rubber latex
  • BD Vialon is proven to enhance clinical and economic outcomes
  • Can be used for taxol administration
  • Sterile

Technology used:

  • BD Push-Button Needle Shielding Technology is demonstrated to reduce needle stick injuries by 95%
  • BD Instaflash Needle Technology on 20, 22 and 24-gauge products incorporate a notched needle that improves first-stick success and reduce painful hit-and-miss insertions
  • BD Vialon Biomaterial is a proprietary catheter material that softens up to 70% in the vein, enables longer dwell times, provides greater kink resistance and reduces the chance of mechanical phlebitis by up to 50%

Parts Description Of BD Insyte Autoguard:



Key Benefits:


  • Increases the ease of penetration
  • Exhibits greater kink resistance
  • Reduces IV restart due to reduced complications and risk of infiltration
  • Increases indwelling time
  • Notched needle technology provides rapid visualization of blood return along the catheter; an excellent choice for fragile vessels or vessels that have lost venous tone
  • Reduces the total IV therapy costs to use due to longer indwelling times
  • Ideal for neonates or geriatrics

More On BD Insyte Autoguard

Points To Practice:

Preparation
  • Make sure all items are accessible throughout the procedure
  • Prepare site according to your facility’s policy and procedure
  • Prior to venipuncture, hold catheter hub and rotate barrel 360 degrees
  • Make sure catheter is seated back in the notch
Venipuncture
  • Approach vein slowly at a low angle
  • Observe flashback along the catheter (20, 22 and 24 gauge only); in larger gauge sizes, observe flash behind the white button
Advancement
  • Upon flashback visualization, lower catheter almost parallel to the skin
  • Before threading, advance entire unit slightly to ensure catheter tip is in the vein
  • Advance catheter into the vein up to the hub, while maintaining skin traction
Needle Removal
  • Before pressing the button
  • Release venous pressure
  • Apply digital pressure beyond the catheter tip
  • Gently stabilize catheter hub
  • Press the white button
Securement
  • Secure catheter and apply sterile dressing according to your facility policy and procedure

Tips For Success:

Insertion Success

  • Make sure the tip seal is released before insertion by rotating the barrel 360 degrees
  • Make sure catheter is seated back in the notch
  • Slow down the speed of insertion
  • Use less force to penetrate the skin
  • Lower the initial insertion angle, keeping the elbow low
  • After flash, lower the angle and advance slightly

Seeing The Flash
  • Trust your instinct and take a pause
  • Look for the flash along the catheter
  • Be aware of patient factors such as small veins, condition of vein, dehydration, hypovolemia, hypotension, polycythemia, etc. that may impact flash

Threading With Ease
  • After flash, lower the angle and advance slightly before threading catheter off the needle
  • Avoid the push-pull technique when advancing
  • Maintain traction on the skin

Retracting The Needle
  • Make sure tip seal is released before insertion by rotating the barrel 360 degrees
  • Make sure to place digital pressure beyond the tip of the catheter
  • Make sure needle is not being inadvertently bent while attempting to activate the button

Minimizing The Blood
  • Release tourniquet (if used) before pressing the button
  • Place digital pressure beyond the catheter tip
  • Have IV connector or tubing close by and ready

Avoid Early Activation
  • Be aware of where your fingers are
  • Remove needle cover in a straight, outward motion

Specification

CodesFlow RateO.D.I.D.Color Code
38151220 mL/min0.0260 to .02900.0190 to 0.0220Yellow
38152335 mL/min0.0330 to 0.03600.0240 to 0.0270Blue
38153365 mL/min0.0410 to 0.04400.0300 to 0.0330Pink
38153460 mL/min0.0410 to 0.04400.0300 to 0.0330Pink
381544105 mL/min0.0500 to 0.05300.0370 to 0.0400Green
38154795 mL/min0.0500 to 0.05300.0370 to 0.0400Green
381554220 mL/min0.0670 to 0.07000.0520 to 0.0550Gray
381557330 mL/min0.0670 to 0.07000.0520 to 0.0550Gray

Customer Reviews

Questions & Answers


 
 
question image
Does it reduce hit and miss insertions?
John - 3/6/2017 5:17:55 AM
facebooktwittergplus
answer image
Instaflash Needle Technology improves first-stick success and reduces painful hit-and-miss insertions by immediately confirming vessel entry, enabling the user to stay focused on the insertion site.
Customer Care - 3/7/2017 12:26:47 AM
question image
What is BD Vialon Biomaterial?
Tessy - 3/6/2017 5:17:21 AM
facebooktwittergplus
answer image
BD Vialon Biomaterial is a proprietary catheter material that softens up to 70% in the vein, enables longer dwell times, provides greater kink resistance and reduces the chance of mechanical phlebitis by up to 50%.
Customer Care - 3/7/2017 12:26:19 AM
question image
How to get a successful insertion?
Olive - 3/6/2017 5:16:55 AM
facebooktwittergplus
answer image
To get a successful insertion with BD Insyte Autoguard Winged Shielded IV Catheter, follow the below instructions:
  • Make sure the tip seal is released before insertion by rotating the barrel 360 degrees
  • Make sure catheter is seated back in the notch
  • Slow down the speed of insertion
  • Use less force to penetrate the skin
  • Lower the initial insertion angle, keeping the elbow low
  • After flash, lower the angle and advance slightly
Customer Care - 3/7/2017 12:25:59 AM
question image
Is there anything to keep in mind while using it?
Yuki - 3/6/2017 5:16:21 AM
facebooktwittergplus
answer image
Keep the following things in mind while using BD Insyte Autoguard Winged Shielded IV Catheter:
  • Do not withdraw needle from catheter hub before pressing the white button 
  • Needle should be retracted prior to disposal into a puncture resistant, leak-proof sharps container per facility protocol
  • Never reinsert needle into the catheter as this could shear the catheter
  • Do not use scissors at or near the insertion site
Customer Care - 3/7/2017 12:25:19 AM
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close