BD Insyte Autoguard  Winged Shielded IV Catheters

BD Insyte Autoguard Winged Shielded IV Catheters

Brand/Manufacturer: BECTON DICKINSON
Earn
5%

Reward$

  • Latex Free

BD Insyte Autoguard Winged Shielded IV Catheter is designed to reduce needle stick injuries. It is made of BD Vialon biomaterial and features stabilizing wings which provide a large surface area for taping down the catheter, thereby improving catheter securement. Instaflash Needle Technology improves first-stick success and reduces painful hit-and-miss insertions. The unique Push-Button Shielding mechanism helps release the spring and allow the needle and flash chamber to quickly retract into the safety barrel, reducing the risk of accidental needle-stick injuries. The clinician can maintain control of the process by deciding when to activate the push-button shielding mechanism.

Item #DescPkg Price 
381512 24G x 0.75" (0.7mm x 19mm) Each $0.20
$5.50
$3.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack $8.00
$220.65
$159.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack, 4PK/Case $28.50
$808.70
$569.99
381523 22G x 1" (0.9mm x 25mm) Each $0.20
$5.50
$3.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack $8.00
$220.65
$159.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack, 4PK/Case $28.50
$808.70
$569.99
381533 20G x 1" (1.1mm x 25mm) Each $0.20
$5.50
$3.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack $8.20
$227.87
$163.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack, 4PK/Case $29.00
$839.99
$579.99
381534 20G x 1.16" (1.1mm x 30mm) Each $0.20
$5.50
$3.99
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack $8.20
$227.87
$163.99
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack, 4PK/Case $29.00
$839.99
$579.99
381544 18G x 1.16" (1.3mm x 30mm) Each $0.20
$5.50
$3.99
381544 18G x 1.16" (1.3mm x 30mm) 50/Pack $8.20
$227.87
$163.99
381544 18G x 1.16" (1.3mm x 30mm) 50/Pack, 4PK/Case $29.00
$839.99
$579.99

BD Insyte Autoguard Shielded IV Catheters

  • Incorporates advanced safety features to provide additional safety to the clinician which facilitates efficient and effective quality care
  • BD Insyte is ideal for emergency, operating, labor and delivery room
  • Reduces hit-and-miss insertion attempts by immediately confirming vessel entry, enabling the user to stay focused on the insertion site
  • This Vascular Access Device allows the user to see the blood return within the catheter before it reaches the flash chamber
  • Provides added confidence when accessing the vein in patients with compromised veins where first-stick success is of special importance
  • Superior tip integrity, ultra-smooth micro-surface and exclusive lubrication process enable for easiest insertion possible
  • Easy to insert, while providing longer dwell times with improved patient outcomes
  • Easier to place and advance on a wider cross-section of patients
  • Reduces the incidence of mechanical phlebitis, a major complication of IV therapy by reducing the chances of irritation to the vessel wall
  • Does not contain elasticized PVC or natural rubber latex
  • BD Vialon is proven to enhance clinical and economic outcomes
  • Can be used for taxol administration
  • Sterile

Technology used:

  • BD Push-Button Needle Shielding Technology is demonstrated to reduce needle stick injuries by 95%
  • BD Instaflash Needle Technology on 20, 22 and 24-gauge products incorporate a notched needle that improves first-stick success and reduce painful hit-and-miss insertions
  • BD Vialon Biomaterial is a proprietary catheter material that softens up to 70% in the vein, enables longer dwell times, provides greater kink resistance and reduces the chance of mechanical phlebitis by up to 50%

Parts Description Of BD Insyte Autoguard:



Key Benefits:


  • Reduces IV restart due to reduced complications and risk of infiltration
  • Notched needle technology provides rapid visualization of blood return along the catheter, an excellent choice for fragile vessels or vessels that have lost venous tone
  • Reduces the total IV therapy costs to use due to longer indwelling times
  • Ideal for neonates or geriatrics

What to buy with Winged IV Catheter?

  • Urocare Uro-Bond III 5000 Silicone Skin Adhesive
  • Atos Medical Provox Adhesive Remover Wipes
  • Coloplast Brava Adhesive Remover Spray

  • How to Use Winged AutoGuard Catheter?

    Preparation
    • Make sure all items are accessible throughout the procedure
    • Prepare site according to your facility’s policy and procedure
    • Prior to venipuncture, hold catheter hub and rotate barrel 360 degrees
    • Make sure catheter is seated back in the notch
    Venipuncture
    • Approach vein slowly at a low angle
    • Observe flashback along the catheter (20, 22 and 24 gauge only); in larger gauge sizes, observe flash behind the white button
    Advancement
    • Upon flashback visualization, lower catheter almost parallel to the skin
    • Before threading, advance entire unit slightly to ensure catheter tip is in the vein
    • Advance catheter into the vein up to the hub, while maintaining skin traction
    Needle Removal
    • Before pressing the button
    • Release venous pressure
    • Apply digital pressure beyond the catheter tip
    • Gently stabilize catheter hub
    • Press the white button
    Securement
    • Secure catheter and apply sterile dressing according to your facility policy and procedure

    Tips For Success:

    Insertion Success

    • Make sure the tip seal is released before insertion by rotating the barrel 360 degrees
    • Make sure catheter is seated back in the notch
    • Slow down the speed of insertion
    • Use less force to penetrate the skin
    • Lower the initial insertion angle, keeping the elbow low
    • After flash, lower the angle and advance slightly

    Seeing The Flash
    • Trust your instinct and take a pause
    • Look for the flash along the catheter
    • Be aware of patient factors such as small veins, condition of vein, dehydration, hypovolemia, hypotension, polycythemia, etc. that may impact flash

    Threading With Ease
    • After flash, lower the angle and advance slightly before threading catheter off the needle
    • Avoid the push-pull technique when advancing
    • Maintain traction on the skin

    Retracting The Needle
    • Make sure tip seal is released before insertion by rotating the barrel 360 degrees
    • Make sure to place digital pressure beyond the tip of the catheter
    • Make sure needle is not being inadvertently bent while attempting to activate the button

    Minimizing The Blood
    • Release tourniquet (if used) before pressing the button
    • Place digital pressure beyond the catheter tip
    • Have IV connector or tubing close by and ready

    Avoid Early Activation
    • Be aware of where your fingers are
    • Remove needle cover in a straight, outward motion

    BD InSyte Winged Shielded Catheters

    CodesFlow RateO.D.I.D.Color Code
    38151220 mL/min0.0260 to .02900.0190 to 0.0220Yellow
    38152335 mL/min0.0330 to 0.03600.0240 to 0.0270Blue
    38153365 mL/min0.0410 to 0.04400.0300 to 0.0330Pink
    38153460 mL/min0.0410 to 0.04400.0300 to 0.0330Pink
    381544105 mL/min0.0500 to 0.05300.0370 to 0.0400Green
    38154795 mL/min0.0500 to 0.05300.0370 to 0.0400Green
    381554220 mL/min0.0670 to 0.07000.0520 to 0.0550Gray
    381557330 mL/min0.0670 to 0.07000.0520 to 0.0550Gray

    Customer Reviews

    Please enter your and your friends email address below.
    Fields marked with * are compulsory
     
    *
    *
    *
    *

     

    SubmitCancel
    The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

    Thank you for using www.healthproductsforyou.com

    Close

    {{VideoGallery[0].VideoName}}

    More Catheters:

    {{x.Name}}
    ${{ x.OurPrice | currency: "" : 2}}

    Articles & news

    Related Articles

    {{x.Heading}}

    {{x.ShortDescription}} ...

    Questions & Answers



    Enter your Answer below.

    Security Question: + =
    question image
    ItemQuestion
    ItemName - now

    Your question will show here once it will get approved.
    answer image
    UserAnswer
    UserName - now
    Your Answer will show here once it will get approved.
    question image
    Does it reduce hit and miss insertions?
    John - 3/6/2017 5:17:55 AM
    answer image
    Instaflash Needle Technology improves first-stick success and reduces painful hit-and-miss insertions by immediately confirming vessel entry, enabling the user to stay focused on the insertion site.
    Customer Care - 3/7/2017 12:26:47 AM
    question image
    What is BD Vialon Biomaterial?
    Tessy - 3/6/2017 5:17:21 AM
    answer image
    BD Vialon Biomaterial is a proprietary catheter material that softens up to 70% in the vein, enables longer dwell times, provides greater kink resistance and reduces the chance of mechanical phlebitis by up to 50%.
    Customer Care - 3/7/2017 12:26:19 AM
    question image
    How to get a successful insertion?
    Olive - 3/6/2017 5:16:55 AM
    answer image
    To get a successful insertion with BD Insyte Autoguard Winged Shielded IV Catheter, follow the below instructions:
    • Make sure the tip seal is released before insertion by rotating the barrel 360 degrees
    • Make sure catheter is seated back in the notch
    • Slow down the speed of insertion
    • Use less force to penetrate the skin
    • Lower the initial insertion angle, keeping the elbow low
    • After flash, lower the angle and advance slightly
    Customer Care - 3/7/2017 12:25:59 AM
    question image
    Is there anything to keep in mind while using it?
    Yuki - 3/6/2017 5:16:21 AM
    answer image
    Keep the following things in mind while using BD Insyte Autoguard Winged Shielded IV Catheter:
    • Do not withdraw needle from catheter hub before pressing the white button 
    • Needle should be retracted prior to disposal into a puncture resistant, leak-proof sharps container per facility protocol
    • Never reinsert needle into the catheter as this could shear the catheter
    • Do not use scissors at or near the insertion site
    Customer Care - 3/7/2017 12:25:19 AM