Why choose Sage PrimaFit External Urine Management System?
- PrimaFit for females is designed to help manage urinary incontinence
- Sure-Stay Silicone Adhesive Pad keeps the device in place
- Ultra-soft wicking Fabric absorbs and diverts urine away from the skin
- Primafit External Catheter has a tapered end cap that gently fits in the perineal area to secure the device in position
- The Tiered Connection Port allows for easy connection to hospital tubing
Why This Product Stands Out?
- It is specifically meant to assist in the management of the urinary incontinence in female patients.
- The Flex-Fit Core shapes itself to the body and retains its form when in use.
- Glues the device securely using Sure-Stay Silicone Adhesive Pad.
- Ultra-soft wicking fabric absorbs and pushes urine off the skin.
- Tapered end cap fits to the perineal region to ensure optimal positioning.
- Tiered Connection Port allows easy connection to hospital tubing.
- It provides a non-invasive alternative to conventional pads and diapers.
- May reduce risks associated with indwelling catheter use.
What to buy with PrimaFit External Female Urinary Catheter?
How does PrimaFit Work?
Primafit is an innovative external urine management system designed to provide a comfortable, non-invasive solution for female patients dealing with urinary incontinence or limited mobility. It helps to manage urinary output while reducing the risk of catheter-associated urinary tract infections (CAUTIs). Primafit is placed externally against the perineal area, where it effectively absorbs and diverts urine into a collection device, keeping the patient dry and comfortable. This device is commonly used in hospitals and long-term care facilities, offering a safer and more hygienic alternative to indwelling catheters. Primafit’s design ensures a gentle fit, reducing skin irritation and the risk of infection, making it an excellent option for improving patient care and hygiene in clinical settings.
How to use PrimaFit External Urine Management System?
Preparations before using PrimaFit External Catheter
- Perform a skin assessment and document per hospital protocol
- Refer to the manufacturer’s instructions for suction setup
Placement of PrimaFit Female Catheter
- Set up a suction canister with tubing per hospital protocol
- Place the patient in the supine position and separate the patient’s legs
- Clean the patient’s genital area from front to back per hospital protocol and assess skin integrity
- Remove the device from the package
- Attach suction tubing. Ensure connection to the device is secure
- Position the device vertically with the tapered end cap facing downward and the white fabric facing the patient’s labia
- Align the tapered end cap with the perineum and place the device between the labia and against the urethral opening. Ensure the absorbent fabric is covering the urethral meatus
- Curve the device toward the patient’s lower abdomen
- While holding the device in place, remove the adhesive liner and smoothly adhere the adhesive pad over the suprapubic region
- Ensure suction tubing does not run under the patient
- Set the vacuum to low, continuous suction at a minimum of 40mmHG. Always use the minimum amount of suction necessary.
- Return patient’s legs to naturally closed position
Points to note while using PrimaFit External Catheter
- Perform a skin assessment periodically per hospital protocol
- Ensure tubing is connected at all times while the device is in use
- Assess the device periodically to ensure proper placement, particularly after turning or repositioning the patient
- Replace the device every 12 hours or if soiled with stool or bodily fluids other than urine. Dispose of the device per protocol.
- Replace tubing and empty and/or replace the suction canister per hospital protocol
Removal of PrimaFit Catheter
- Place the patient in the supine position and separate the patient’s legs
- Gently remove the adhesive pad.
- Separate the labia and remove the device
- Assess skin integrity and perform perineal care.
- Disconnect the device from the suction tubing and discard the device per hospital protocol.
Cautions
- It is not intended for use on patients in the prone position
- Not intended for use on male patients
- It is not intended for stool collection
- Use caution if using on patients with altered mental status
- Remove the device during ambulation
Discontinue use when independent or assisted toileting is feasible
Frequently Asked Questions
1. Who is the Sage PrimaFit system designed for?
It is specifically designed for female patients who need help managing urinary incontinence or have limited mobility.
2. How does an external urine management manage urine?
It is an external product that is put against the perineal region and absorbs urine diverting it into a collection system.
3. How often should the device be changed?
The device is supposed to be changed after every 12 hours or earlier in case it is contaminated with stool or other body fluids.
4. Does Sage PrimaFit External Urine Management allow walking or ambulation?
The device should be removed during ambulation and cannot be used while walking or ambulating.
5. Is PrimaFit suitable for all patient positions?
No, it should not be used on patients in the prone or face-down position.
6. Can this device be used for male patients or stool collection?
The product should not be used to collect stool. It is meant only for female patients and not for any male patient.