MIC-KEY Bolus Extension Set Features
- Low-profile, easy-to-conceal design
- Clear tubing to enhance visibility
- Secure lock-and-key style connection
- Reusable for single-patient use
- DEHP-free formulation
- Includes tubing clamp and connectors
- Supports enteral nutrition and medication delivery
- Individually wrapped and easy to handle
MIC-KEY Extension Set Composition:
- Enteral Adapter: ABS
- Extension Set Tubing: PVC
- Connectors, Straps: PVC
- Clamps: Polypropylene
When to use?
- When a person is unable to tolerate oral feeding
- After a surgery
- When a person cannot get enough nutrition via eating or drinking orally
Why to Use This Product?
- Specifically created to be used with MIC-KEY low-profile feeding tubes.
- Provides effective enteral nutrition and medication.
- Key connector with lock is to guarantee a stable and secure connection.
- Formula flow can be easily monitored with clear tubing.
- Lightweight and flexible to enhance convenience and mobility.
- Easy to clean and reuse for the same patient.
- The low profile design allows it to be less visible under clothing.
- Made from durable materials like PVC, ABS, and polypropylene
- Â
Frequently Bought Together
How to Bolus Feed?
- Clean your hands.
- If you own a low-profile feeding tube, prime the extension tubing to eliminate any air before connecting it to the feeding tube. Priming the tubing helps block air from entering your stomach and creating distress.
- Clamp the extension set.
- Remove the syringe's plunger and connect the needle to the extension tubing.
- Fill the syringe with about 15 mL of the formula.
- Unclamp the extension set and let the formula flow just to the end of the tubing before clamping it.
- Connect the feeding tube to the extension set.
- If you have a gastrostomy tube, flush your tube with water.
- Take out the syringe's plunger.
- Connect your feeding tube to the syringe.
- Fill the syringe with 10-15 mL of water and let it flow through your tube.
- Rinse the outside of your formula vessel with a neat towel and open it.
- One hand is used to hold the tube and syringe.
- Gradually pour the formula into the syringe with your other hand. Please leave it to flow by gravity into your stomach. It should take about 15 minutes to deliver 8 ounces of formula.
- You can make the formula flow quicker by raising the syringe to your stomach.
- You can gradually make the formula flow by lowering the syringe to your stomach.
- Wash your feeding tube with the amount of water suggested.
- Close the feeding port and disconnect the extension tubing (if applicable). Clean your hands. Wash and air-dry all accessories and supplies.
- Refrigerate any remaining formula and use it within 24 hours.
Cleaning Instructions
- Wash the tubing with warm water and mild soap, and rinse well.
- Let it air dry and then store it in a clean place until the next use.
- The one-way valve in the MIC-KEY may be damaged and cause leaks if left in place for too long.
Frequently Asked Questions -
1. What is the MIC-KEY Bolus Extension Set used for?
It is applied to provide enteral nutrition or medication via compatible MIC-KEY feeding tubes.
2. Is the extension set reusable?
It can be reused by the same patient, but must not be used by other patients.
3. Can the tubing be cleaned?
Yes, it can be washed with warm water and mild soap, then air-dried before reuse.
4. What type of feeding tubes can it be used with?
It is compatible with MIC-KEY low-profile gastrostomy, jejunal and gastric-jejunal feeding tubes.
5. What materials are used in the extension set?
It is made from materials like PVC, ABS, and polypropylene.
6. When to use this extension set?
This is applied when an individual is intolerant to oral feeding, has undergone surgery or cannot receive adequate nutrition through eating or drinking.
Related Articles
{{x.ShortDescription}} ...
Share
MIC Key Bolus Extension Set Reviews