Drive Med Aire Alternating Pressure Pump and Pad System

Brand/Manufacturer: DRIVE MEDICAL
Item # Desc Pkg Price
14002E Deluxe Pad with Fixed Pressure Pump $3.00
$80.60
$59.99
14001E Standard Pad with Variable Pressure Pump $3.55
$110.99
$70.99
14001EFD Deluxe Pad with End Flaps and Variable Pressure Pump $4.95
$145.80
$98.99

Drive Med Aire Alternating Pressure Pump and Pad System is made of long lasting durable heavy gauge premium vinyl with bubble pad which provides superior therapeutic treatment. Its 130 individual bubble cells gives maximum comfort and effectiveness while the quite pump alternately inflates and deflates the air cells. The variable pressure setting on the deluxe pump allows comfort setting for the maximum comfort and compliance.

When to use Drive Med Aire Alternating System?

The Med Aire series is intended to reduce the incidence of pressure ulcers while optimizing patient comfort. It also is appropriate for the following:

  • Individual home care setting and long-term care facilities
  • Pain management as prescribed by a physician

Features of Drive Med Aire Alternating Pressure Pump and Pad System

  • Quiet pump alternately inflates and deflates 130 individual bubble air cells
  • Drive Med Aire Alternating Pressure Pump and Pad System has built-in-bracket for mounting easily to bed
  • 4 LPM (liters per minute) pump produces consistent air flow and pressure over a five minute cycle time
  • Variable pressure setting on pump allows for individualized comfort increasing patient complaince
  • Durable, heavy gauge, premium vinyl bubble pad provides superior therapeutic treatment and is available with or without end flaps/Pump has built-in brackets for mounting easily to bed

Note: This item cannot be returned or exchanged once they are opened due to hygienic reasons

Drive Med Pump and Pad System User Guide

What to buy with Alternating Pressure System


How to install Med-Aire Alternating Pressure Pump and Pad System?

  1. Place the bubble pad flat on a base mattress, which should be on a bed frame. The inflation tubes should be towards the foot end so that they can be connected to the inflation nozzles on the pump.
  2. Cover with a cotton sheet to avoid direct skin contact and reduce friction
  3. Hang the pump over the frame or board at the foot end of the bed. Make sure the pump is secured
  4. Connect the inflation tubes from the bubble pad to the pumps inflating nozzles. Make sure they are properly attached
  5. Cautions: Make sure the inflation tubes are not kinked or tucked under the pad
  6. Plug the power cord into an electrical outlet with grounded AC power
    If the power cord has a grounding wire with a grounding pin, then this three-wire plug must be plugged properly into an outlet and grounded
  7. Turn on the power by pressing the power switch at the right side of the pump. Proceed to the Operation section
  8. Make sure to disconnect the pump by unplugging the power cord when it is not in use
Grounding Instructions:
  • This product should be grounded when it is equipped with a cord that contains a grounding wire with a grounding plug
  • In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current

How to clean Drive Med Aire Alternating Pressure Pump and System?

In this section, we describe the procedures to clean and decontaminate the pump and bubble pad. It is important to follow these procedures before using the system on patients. The cleaning task is required at least once a week to maintain personal hygiene.

How to clean Drive Medical Med Aire Alternating Pressure System?

  • Do not immerse or soak the pump
  • Check for external damage and move the pump to a cleaning area
  • Place the pump on a work surface and spray or wipe the outside of the case with quaternary ammonium solution
  • Do not spray any cleaning solution directly on the surface of the pump
  • Do not use a Hypocarbonate or Phenolic based cleaning solution as this may cause damage to the case. Allow the solution to incubate for 10 minutes or accordingly as stated by the cleaning product used.
  • Spray cloth with cleaning solution and clean faceplate. Do not allow excess cleaning solution on faceplate or control panel. (If solution gets inside, damage will occur.) Allow surface to thoroughly dry after cleaning.
  • After the pump is thoroughly cleaned and dried, proceed to plug in the pump and test to see if it runs normally

Cleaning Bubble Pad:

  • Any obvious blood spots should be cleaned thoroughly with 1:9 Hypochlorite solution (1 part bleach to 9 parts water) and allow drying for at least 10 minutes. Then blot with a clean, damp cloth.
  • Brush or wipe down all surfaces with soap and water before applying any liquid
  • Allow it to thoroughly air dry. Once the inside is dry, turn it back: wipe down the outside of the bag with disinfectant.
  • Dry the bubble pad away from direct sunlight after cleaning

Handling And Storage:
  • Lay the bubble pad flat. Fold or roll it carefully
  • Unplug the pump and store with proper identification tag
  • Follow the national requirement to dispose the pump
Warnings: To reduce the risk of burns, electrocution, fire, or injury to persons:
  • A product should never be left unattended when plugged in.
  • Close supervision is necessary when this product is used by, on, or near children or physically challenged individuals.
  • Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
  • Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the product to a service center for examination and repair.
  • Keep the cord away from heated surfaces.
  • Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and the like.
  • Never drop or insert any object into any opening or hose.
  • Do not use this product in or near explosive atmospheres, or where aerosol (spray) products are being used.
  • Do not pump combustible liquids or vapors with the product or use in or near an area where flammable or explosive liquids of vapors may exist.
  • Do not operate this product in an oxygen enriched environment, i.e. oxygen tent or oxygen hood.
  • Use only in well ventilated areas.
  • Connect this product to a properly grounded outlet only.
Contraindications: Patient conditions for which the application of pressure relieving therapy on an alternation system is contraindicated are as follows:
  • Cervical or skeletal traction
  • Unstable spinal cord injuries

Warning WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Drive Alternating Pressure Pump and Pad System Specifications

Particulars

Specifications

Pump

Size

8.8” x 4.2” x 4”

Weight

3.1lbs

Pressure Range

14002E: 100 mmHg
14001E: 45 to 110mmHg

Air Output

>4 liter/min

Power Consumption

7W

Power Supply

110V/60 Hz

Fuse

1A

Cycle Time

12 min

Pad

Standard & Deluxe

78"L x 36"W x 2.5"H

Deluxe with End Flaps

123" L x 36" W x 2.5" H

Weight Capacity

300lb

System

Input Rating

AC 120V 60Hz or 100V 50/60Hz or 230V 50Hz 12W, 1A

Environment Requirements

Temperature: Operation 50°F~95°F (10~35°C)
Storage 5°F ~122°F (-15~50°C)
Shipping 5°F ~158°F (-15~70°C)
Humidity: Operation 20%~80% non-condensing
Storage 10%~90% non-condensing


Drive Med Aire System Warranty

1 Year warranty on pump, 90 days warranty on pad

Drive Med Aire Alternating Pressure System Reviews

+=
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.

01

Question

GEE PALACOL     01/23/2017

The mattress seems have a Vibrating mechanism but only at one end of the bubble pad mattress. So we put it at the HEAD OF THE MATTRESS (ALONG WITH THE PUMP) THINKING THIS MIGHT HELP OUR 86 YEAR OLD MOTHER SLEEP BETTER.  SHOULD THE PUMB AND TUBINGS BE AT THE HEAD OF THE BED OR THE FOOT OF THE BED..........DOES IT MATTER???????????? 

Answer

Customer Care    01/25/2017

The inflation tubes of Med Aire Alternating Pressure Pump and Pad should be towards the foot end so that they can be connected to the inflation nozzles on the pump.

And also hang the pump over the frame or board at the foot end of the bed to make sure the pump is secured.

{{x.Heading}}

{{x.ShortDescription}} ...

What is HPFY’s return policy?

Customer satisfaction is our top priority. We stand behind our products. If the merchandise you received is defective or not what you expected it to be, and you wish to return the item, please submit a return request in the My Account section of our website, contact our Customer Service department at (866) 316-0162 / (203) 616-2850 or email us.

  1. Merchandise must be returned within 30 days of the receipt of your order. Returns are not accepted after 30 days.
  2. Items (including parts and accessories) must be returned in new, unused, and resalable condition in its original packaging.
  3. Before returning any product, the buyer must obtain a Return Authorization Number (RA#) from a customer service representative. With your RA# you will receive a prepaid return shipping label.
  4. Orders returned without obtaining an RA# will be entitled to receive only "In-Store Credit" that can be used towards future purchases.
  5. Return orders are subject to a 20% restocking fees.
  6. All custom orders and hygienic items are non-returnable. Refer to the “Non-Returnable Items” section for further details.
  7. Returns will be reviewed and inspected before issuing credit. Please allow 3 to 4 weeks for processing. The credit will be applied to your original method of payment.
  8. If the return is the result of a defective product or shipping error, we will refund the entire purchase amount and return shipping costs.

Which products are Non-Returnable?

Due to the hygienic nature of some items, they are non-returnable. The items listed below are non-returnable:

  1. All hygienic items.
  2. Opened personal care items.
  3. Anything opened, used, or tried on.
  4. All customized items.
  5. Besides these, items that have the “non-returnable” phrase on the website.

We reserve the right to make adjustments due to errors, changing market conditions, product discontinuation or typographical errors in advertisements. Images on the site may not always reflect the actual product. Footrests or leg-rests are not included with wheelchairs unless specified.

How do I receive a return authorization number?

You can submit a return request by logging into your account. You will receive the Return Authorization Number (RA#) details in the email within 2-3 business days.

  • Login to your account
  • Go to “order history”
  • Click on “return order”
  • Fill out the return form and Submit it

If you do not have an email address, we will make other accommodations for RA# Details. Write the RA# on your label affixed to your package prior to shipment.

How long does it take to receive a refund?

Please allow 3 to 4 weeks to process the returns. Once the item is received, and inspected, your refund will be processed and automatically applied to your credit card or original method of payment.

Is there any Restocking Fees?

  1. 20% restocking fees will be applied.
  2. Outbound shipping cost is non-refundable.
  3. For orders that qualified for free shipping, $8.99 will be deducted from the refund if the product is returned.

More Drive Mattress

{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 

Submit Cancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close