Covidien DAR Adult or Pediatric Electrostatic Filter Heat and Moisture Exchanger

Covidien DAR Adult or Pediatric Electrostatic Filter Heat and Moisture Exchanger

Brand/Manufacturer: COVIDIEN/MEDTRONIC
Earn
3%

Reward$

This product is on backorder and will be available to purchase once it is back in stock.

Covidien DAR Adult or Pediatric Electrostatic Filter Heat and Moisture Exchanger reduces set-up time, minimizes dead space and weight on endotracheal tube and circuit while maximizing efficiency. Electrostatic hydrophobic membrane protects against cross-contamination and hygroscopic membrane traps patients moisture providing effective airway humidification. It features low resistance to airflow to minimize work of breathing.

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

Features

  • Covidien DAR Adult or Pediatric Electrostatic Filter Heat and Moisture Exchanger has effective moisture control which reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • End tidal CO2 sampling port offers convenient access to airway gases
  • ISO standard 15mm and 22mm fitting connects with breathing system
  • Treated with physiologically safe calcium chloride
  • Supplied clean and individually packaged
  • Indications for usage:
    - Adult (recommended tidal volume >150ml), single patient use on anesthetized patients and respiratory care patients who require a breathing circuit
    - Intended to be replaced at least once every 24 hours

Specification

ParticularsDimensions
Resistance to Flow (ISO 9360)

30 l/min : 1.0cm H2O

60 l/min :  2.8cm H2O

90 l/min : 4.7cm H2O

Bacterial Filtration Efficiency>99.99%
Viral Filtration Efficiency>99.99%
Dead space49ml
Weight28gm
Type of FiltrationElectrostatic
Recommended Tidal Volume>150ml
Moisture output and temperature at 2 hours (ISO 9360)

Vt 250ml : 34.4mg H2O/l @32.5oC

Vt 500ml : 33.6mg H2O/l @ 32.3oC

Vt 750ml : 30.1mg H2O/l @ 30.6oC

Vt 1000ml : 32.9mg H2O/l @ 32.2oC

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 

SubmitCancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close

{{VideoGallery[0].VideoName}}

Also available:

${{ x.OurPrice | currency: "" : 2}}

Articles & news

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Questions & Answers



Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image
I have the same question as John.  I have a DAR Electrostatic filter for adult Ped # 352u5877 which confirmed was good for use on COVID patient but I also have a Adult Ped HME filter # 353u5413..this is an older filter but we have some boxes of both in our warehouse.  Can we use the HME filter #353u5413 on COVID 19 patients ?
Mickey - 4/21/2020 3:17:55 PM
answer image
Dear customer, we will not be able to assist you for your query, we shall consult the doctor for the same.
Customer care - 4/23/2020 3:54:06 PM
question image
Does the HME contain a viral retentive component or does it need to be used in unison with the separate viral retentive filter for COVID patients?
John - 3/17/2020 5:49:52 PM
question image
DOES THIS DEVICE ELIMINATE THE NEED FOR HUMIDIFICATION ON TRACH PATIENTS AND FOR HOW LONG AND IS IT COMPATABLE WITH ALL TRACHS ...INCLUDING THE FIVE JACKSON ?
LOUIS SANTONI - 2/6/2015 8:26:43 PM
answer image
HMEs, or Heat and Moisture Exchangers, capture heat and water vapor from a patient’s exhaled air. Then during inhalation, they add heat and moisture to the inspired air, providing the appropriate humidification.
Customer Care - 2/10/2015 4:51:26 AM