Estimated Shipping Time: 8-12 Business Days

Cardinal Health NPWT Pro Therapy System

Brand/Manufacturer: CARDINAL HEALTH
To place an order or check availability
Item # Desc Pkg Price
6708888 NPWT Pro Device $35.10
$1,450.45
$1,169.99

Cardinal Health NPWT Pro Therapy System is an integrated wound management system indicated for the application of continual or intermittent Negative Pressure Wound Therapy(NPWT), also known as wound vacuum therapy. The PRO therapy system promotes wound healing by the removal of fluids and infectious materials. The PRO NPWT System is intended for use in acute, extended and home care settings. This NPWT Device is a 42-day device that permits clinicians to accept NPWT patients and initiate NPWT therapy immediately.

Why choose NPWT Pro Device?

  • Small, lightweight device
  • Quiet operation
  • Optimal patient discretion
  • Simple & easy operation

Features of NPWT Pro Therapy System

  • Simple Operation - Therapy activation and changing of Pressure Settings can be accomplished with just a push of a button. Lights next to the Pressure Settings clearly indicate current therapeutic settings.
  • Light Weight/Impact Resistant - The PRO weighs only 0.4kg (0.9 lb.) and can be easily carried. The NPWT PRO comes with a cover that is impact resistant to help prevent damage from dropping.
  • Noise - The PRO is quiet in its normal operation with a well-sealed dressing.
  • Battery - An internal battery in the PRO provides up to 24 hours of operation from a fully-charged battery. The battery charges while PRO is plugged into an outlet with the A.C. Power Adapter. If the battery charge is less than 20%, the system beeps in counts of 3 and a low battery "3" alert is displayed as well.
  • Power/Charging Status - The system also has an alert for showing when it is charging its internal battery and/or when its running on external power.
  • Intermittent Mode - The PRO can be set to operate intermittently (5-minute ON/2-minute -25mmHg pressure cycle).
  • Alert Display - It consists of automated alerts for Low Pressure/Leak, Canister Full, Low Battery and Therapy Timer. Alerts are both visual and audible. Alerts self-reset once the problem is corrected or can be manually reset by turning the PRO off and then back on. Audible alerts can be muted for 5 minutes by pressing and holding the ON button until a series of beeps is heard. The alert continues to flash in the Alert Display while the PRO is muted.
    - NOTE: Alert 4(Service Timer) cannot be silenced or reset.
  • SpeedConnect - The NPWT PRO comes with 8-foot, single-lumen tubing set. An adhesive SpeedConnect makes connection to the dressing quick and easy.
  • Canisters - The NPWT Device is intended for use with 300cc and 500cc canisters. Both canisters can be used for normal and highly exudating wounds.

In order to assure the highest safety, quality and efficacy, the PRO should only be used with the Cardinal Health NPWT Dressing Kits and Cardinal Health NPWT disposables. Use of any other brand of wound dressings are not compatible with the PRO and are not recommended.


Also Available (Separately) - Cardinal Health NPWT PRO TO GO Kit

What to buy with Cardinal health NPWT Pro?


Parts of PRO NPWT Device

Labeled arts of NPWT PRO Therapy System

When to use Negative Pressure Wound Therapy System?

The PRO NPWT system is an integrated wound management system, indicated for the application of continual or intermittent negative pressure wound therapy to the wound. It may promote wound healing by the removal of fluids, including wound exudates, irrigation fluids, body fluids, and infectious materials. The PRO system is intended for use in acute, extended, and home care settings. The PRO NPWT system is intended for patients with:


How to use the NPWT Pro Device?

  • Insert NPWT Canister - Insert canister in holder by sliding it up into bottom of the Canister Holder. Line up the two short ports with the Canister Holder and press until it “clicks” into place and locks. To remove canister, press Canister Release Button, grasp canister at bottom and pull downward.
  • Connect the Dressing - Connect the blue end of the tubing to the open port of the canister. Gently twist and push connector on just enough to seal it. Make sure that the clamp on the tubing is open. NOTE: Please refer to the Cardinal Health NPWT PRO Clinician User Manual for instructions on how to properly dress the wound and troubleshoot issues.
  • Turning the PRO Device ON - Press the ON button to start therapy. Select the desired Pressure Setting by pressing the UP or DOWN arrow button. A green light begins flashing next to the selected Pressure Setting. The light flashes and remains lit when the set pressure is reached. The light flashes if the pressure cannot be maintained.
  • Therapy Lockout - To lock Therapy Setting, press and hold the ON button for 3 seconds. The PRO beeps three times indicating negative pressure wound Therapy Setting is locked. Repeat process to unlock negative pressure wound Therapy Setting.
  • Intermittent Mode - To operate the device in Intermittent Mode, press the Intermittent Mode Button. An amber light indicates the PRO is operating in Intermittent Mode. Repeat process to return to Continuous Mode.
  • Adjust Alert Volume - Volume may be adjusted by pressing and holding the ON Button and tapping the UP or DOWN arrow button. The numbers 1 to 5 will appear in the Alert Display. The No. 1 is the lowest; No. 5 is the highest volume level.
  • Turning the PRO Device OFF - To turn PRO off, press the OFF Button. The Alert Display flashes “o-f-f” three times while the PRO is preparing to shut down.
NOTE: Please refer to the Cardinal Health Negative Pressure Wound Therapy (NPWT) PRO Clinician User Manual for detailed instructions and review the Precautions and Contraindications before use.

Cleaning and Maintenance of NPWT System

Daily Care and Cleaning

Perform a visual inspection of the device. Check for any sign of contamination and in particular any fluid ingress and ensure that the device is functioning properly. If the device is not operating properly, refer to the Alarm Troubleshooting guide in the 4. OPERATING INSTRUCTIONS section of this manual or contact Cardinal Health to replace the device.

Between Patient and Weekly Care and Cleaning

The following cleaning procedure must be performed at least once a week and must be completed between patients. The Cardinal Health NPWT PRO family of devices should be wiped with either a diluted solution of 5 milliliters bleach in 1 liter of warm water (approximately 1 teaspoon bleach in 1 quart water) or mild disinfectant. Use a coarse cloth and wring out any excess solution until the cloth is damp and not dripping.

Cardinal Health NPWT Device Manuals & Guides

Patient User Manual
Patient Quick Reference Guide
Clinician User Manual
Clinician Quick Reference Guide

Specifications of Cardinal Health NPWT Device

ParticularsSpecifications
DeviceDimensions6 x 4.3 x 2.75 in. (19.3 x 11.0 x 7.0 cm)
Weight0.9 Lbs (0.43Kg)
Therapy Settings50, 75, 100, 125, 150 mmHg
Canister Volume300cc/500cc
BatteryDuration (Fully Charged)up to 24 hours
ElectricalExternal Power Supply Input100-240 VAC, 50-60Hz, 200 mA or 12-24 VDC, 850 mA (Optional)
External Power Supply Output5 VDC, 1 Amps
Patient & Enclosure Leakage Current< 100 Micro amps
Storage ConditionsTemperature Range10°F (-12°C) to 1100F (43°C)
Relative Humidity Range20 – 95% Non-condensing
Atmospheric Pressure Range50 kPa to 110 kPa
Operating ConditionsTemperature Range40°F (4°C) to 90°F (32°C)
Relative Humidity Range20 - 75% Non-condensing
Atmospheric Pressure Range50 kPa to 110 kPa
Service Life3 years

Customer Reviews

+=
Question

ItemName - now     01/25/2021

ItemQuestion
  Your question will show here once it will get approved.
Answer

UserName - now     01/25/2021

UserAnswer
  Your Answer will show here once it will get approved.

{{x.Heading}}

{{x.ShortDescription}} ...

What is HPFY’s return policy?

Customer satisfaction is our top priority. We stand behind our products. If the merchandise you received is defective or not what you expected it to be, and you wish to return the item, please submit a return request in the My Account section of our website, contact our Customer Service department at (866) 316-0162 / (203) 616-2850 or email us.

  1. Merchandise must be returned within 30 days of the receipt of your order. Returns are not accepted after 30 days.
  2. Items (including parts and accessories) must be returned in new, unused, and resalable condition in its original packaging.
  3. Before returning any product, the buyer must obtain a Return Authorization Number (RA#) from a customer service representative. With your RA# you will receive a prepaid return shipping label.
  4. Orders returned without obtaining an RA# will be entitled to receive only "In-Store Credit" that can be used towards future purchases.
  5. Return orders are subject to a 20% restocking fees.
  6. All custom orders and hygienic items are non-returnable. Refer to the “Non-Returnable Items” section for further details.
  7. Returns will be reviewed and inspected before issuing credit. Please allow 3 to 4 weeks for processing. The credit will be applied to your original method of payment.
  8. If the return is the result of a defective product or shipping error, we will refund the entire purchase amount and return shipping costs.

Which products are Non-Returnable?

Due to the hygienic nature of some items, they are non-returnable. The items listed below are non-returnable:

  1. All hygienic items.
  2. Opened personal care items.
  3. Anything opened, used, or tried on.
  4. All customized items.
  5. Besides these, items that have the “non-returnable” phrase on the website.

We reserve the right to make adjustments due to errors, changing market conditions, product discontinuation or typographical errors in advertisements. Images on the site may not always reflect the actual product. Footrests or leg-rests are not included with wheelchairs unless specified.

How do I receive a return authorization number?

You can submit a return request by logging into your account. You will receive the Return Authorization Number (RA#) details in the email within 2-3 business days.

  • Login to your account
  • Go to “order history”
  • Click on “return order”
  • Fill out the return form and Submit it

If you do not have an email address, we will make other accommodations for RA# Details. Write the RA# on your label affixed to your package prior to shipment.

How long does it take to receive a refund?

Please allow 3 to 4 weeks to process the returns. Once the item is received, and inspected, your refund will be processed and automatically applied to your credit card or original method of payment.

Is there any Restocking Fees?

  1. 20% restocking fees will be applied.
  2. Outbound shipping cost is non-refundable.
  3. For orders that qualified for free shipping, $8.99 will be deducted from the refund if the product is returned.

More Wound Prep Supplies

{{'Buy ' + x.Name}}
{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 

Submit Cancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close