Bard Bardex Economy Lubricath Two-Way Foley Catheter With 5cc Balloon Capacity
Bard Bardex Economy Lubricath Two-Way Foley Catheter With 5cc Balloon Capacity

Bard Bardex Economy Lubricath Two-Way Foley Catheter With 5cc Balloon Capacity

Brand/Manufacturer: BARD INC
Save

Bard Bardex Economy Lubricath Two-Way Latex Catheter With 5cc Balloon Capacity provides for smoother insertion. Lubricath Foley Catheter offers enhanced patient comfort through the hydrogel coatings unique ability to absorb fluid, thus creating a hydrophilic cushion between the catheter surface and the urethra.

Item #DescPkgPrice 
365712 12FR Each $12.75 $4.99
365712 12FR 12/Case $90.65 $52.99
365714 14FR Each $12.75 $4.99
365714 14FR 12/Case $90.65 $52.99
365716 16FR Each $12.75 $4.99
365716 16FR 12/Case $90.65 $52.99
365718 18FR Each $12.75 $4.99
365718 18FR 12/Case $90.65 $52.99
365720 20FR Each $12.75 $4.99
365720 20FR 12/Case $90.65 $52.99
365722 22FR Each $12.75 $4.99
365722 22FR 12/Case $90.65 $52.99
365724 24FR Each $12.75 $4.99
365724 24FR 12/Case $90.65 $52.99
365726 26FR Each $12.75 $4.99
365726 26FR 12/Case $90.65 $52.99

Inflation/Deflation Guidelines

  • Catheter Inflation:
    - Ensure that the Bard Foley catheter balloon is positioned well within the patients bladder. Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package
    - Note that the 5cc balloon must be inflated with between 9cc to 10cc of sterile water
    - Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties
    - Using fluid other than sterile water may cause the balloon not to empty properly, especially after long dwell times
  • Catheter Deflation:
    - Select a luer slip syringe
    - Slide the plunger of the syringe up and down the barrel of the syringe several times to loosen it up
    - Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    - Gently insert the syringe in the catheter valve
    - Do not use more force than is required to make the syringe stick in the valve
    - Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    - If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own
    - If the balloon does not deflate, reposition the patient.
    - Ensure that the catheter is not in traction, the proximal end of the catheter is not compressed within the bladder neck
    - Ensure that urine flows freely
    - Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above
    - If the balloon stills fails to deflate, apply very gentle slow aspiration. Aspiration that is too rapid, or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    - If permitted by hospital protocol, the valve arm may be severed
    - If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Specification

Catheter TipRound Tip
Catheter MaterialLatex

Gender

Unisex

Catheter French Size

12FR,14FR,16FR,18FR,20FR,22FR,24FR,26FR

Ballon Size (CC)

5cc

Customer Reviews

Questions & Answers


 
 
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close