Advent Phoneris Replacement Inner Cannula

Brand/Manufacturer: MEDLINE INDUSTRIES
Item # Desc Pkg Price
HCSTIC4A Size 4 $2.25
$65.99
$44.99
HCSTIC8A Size 8 $2.25
$65.99
$44.99

Advent Phoneris Inner Cannula provides a specially designed integrated system for a more secure connection between the inner cannula and ventilator circuit. It eliminates the need for improvised securing devices, rubber bands, tapes, etc. which can increase the incidence of skin breakdown. Improves staff efficiency by decreasing the incidence and urgency of unplanned disconnections and ease of passing inline suction catheter.

Phoneris Replacement Inner Cannula Features

  • Advent Phoneris Inner Cannula is a sterile replacement inner cannula intended to be utilized in the tracheostomy tube
  • Designed to specifically mate with the appropriate Phoneris AeroFlex Ventilator Circuit
  • Connector of the same style to decrease the risk of disconnection
  • Phoneris Inner Cannula is indicated for maintenance of patients with tracheostomies
  • Single use, disposable devices which is an accessory to a tracheostomy tube, serving as an interlocking, detachable, coupling between the ventilator circuit and tracheostomy tube
  • Supplied individually packaged and sterile

What to buy with Advent Phoneris Inner Cannula


How to use Phoneris Inner Cannula?

  • Utilizing your institutions protocol for Airway maintenance, prepare the patient for the replacement of the Phoneris Inner Cannula by collecting all required supplies including the Phoneris Inner Cannulae and the Phoneris AeroFlex Ventilator Circuit Connector
  • Be certain that the Phoneris Inner Cannula is the correct size and style for the tracheostomy tube of the patient
  • Use universal protection when changing the Phoneris Inner Cannula
  • Prepare a clean working area
  • Open all packages
  • Turn the ventilator to stand-by mode
  • Disconnect the ventilator circuit from the Phoneris AeroFlex Ventilator Circuit Connector
  • Disconnect the Phoneris AeroFlex Ventilator Circuit Connector by rotating the Phoneris AeroFlex Ventilator Circuit Connector clockwise or counterclockwise until the Phoneris AeroFlex arms are disengaged from the Phoneris Inner Cannula
  • Remove the Phoneris Inner Cannulae from the tracheostomy tube by squeezing the tabs on the 15mm connector until both snap-locks clear the ridged lock on the outer cannula
  • Withdraw slowly
  • Dispose of the removed Phoneris Inner Cannula
  • Clean the tracheostomy tube if necessary
  • The Phoneris Inner Cannula may be moistened with sterile saline or a water soluble lubricant to facilitate insertion

Note
  • If using a water soluble lubricant verify that the lubricant does not enter and occlude the tracheostomy tube lumen which may restrict ventilation.
  • It is recommended that the Phoneris Inner Cannula be replaced a minimum of every 24-hours or sooner if required by your institutions written policies and procedures for airway maintenance.

Warning
  • Determine the brand and size of the patients tracheostomy tube
  • Be certain that the Phoneris Inner Cannula is the correct style and size for the tracheostomy tube
  • Should only be used by trained personnel
  • Inner Cannulae is for single patient use only. Do not reuse.
  • Inner Cannulae is supplied sterile. Do not use if the package has been opened, damaged or broken. Do not resterilize.
  • Do not use if the package has been opened, damaged or broken.
  • Do not use the Phoneris Inner Cannula if the use date is beyond the expiration date printed on packaging.
  • Prior to utilizing the Phoneris Inner Cannula ensure that the tracheostomy tube is properly secured to the patient through appropriate means so as to prevent accidental decannulation.

Caution
  • The Phoneris Inner Cannulae is manufactured from medical grade plastics and do not contain latex material.
  • Care should be taken when disposing of either the Phoneris Inner Cannula to ensure compliance with applicable regulations for the disposal of biologically hazardous waste.

Storage
  • Store the Phoneris Inner Cannula in their original packaging under controlled environmental conditions
  • Do not expose the Phoneris Inner Cannula to temperatures above 120ºF (40ºC).
  • To avoid applying pressure against the patient, the tabs on the connector should be held open, while the neck plate is stabilized with your free hand during the locking procedure.
  • Insert the Phoneris Inner Cannula with 15 mm snap-lock connector and lock into position.
  • To lock the Phoneris Inner Cannula in place, push connector until both snap-locks clear the ridged lock on the outer cannula.

Note
  • It may be easier to lock one side of the Inner Cannulae first and then lock the second side of the Inner Cannula
  • Check to ensure that both locks are appropriately engaged on the outer cannula.
  • Attach the Phoneris AeroFlex Ventilator Circuit Connector to the Phoneris Inner Cannula by aligning the arrows and engaging the fingers on the Phoneris AeroFlex Ventilator Circuit Connector to lock on the ridge of the Phoneris Inner Cannula.
  • Ensure both fingers on the Phoneris AeroFlex are in the locked position to the Phoneris Inner Cannula.
  • Attach the Phoneris AeroFlex Ventilator Circuit Connector to the ventilator circuit.
  • Check to ensure maintenance of a constant seal to the ventilator circuit.
  • Turn the ventilator from stand-by mode to on and resume the previous ventilator settings or if ordered by the physician, change the ventilator settings to the new settings.
  • The patients respirations and vital signs should be routinely evaluated after replacing the Phoneris Inner Cannula and the Phoneris AeroFlex Ventilator Circuit per your institutions protocol.
  • If there are problems then the attending physician should be immediately contacted.

Phoneris Replacement Cannula Warranty

Limited Lifetime.


Customer Reviews

+=
Question

ItemName - now     12/07/2021

ItemQuestion
  Your question will show here once it will get approved.
Answer

UserName - now     12/07/2021

UserAnswer
  Your Answer will show here once it will get approved.

{{x.Heading}}

{{x.ShortDescription}} ...

What is HPFY’s return policy?

Customer satisfaction is our top priority. We stand behind our products. If the merchandise you received is defective or not what you expected it to be, and you wish to return the item, please submit a return request in the My Account section of our website, contact our Customer Service department at (866) 316-0162 / (203) 616-2850 or email us.

  1. Merchandise must be returned within 30 days of the receipt of your order. Returns are not accepted after 30 days.
  2. Items (including parts and accessories) must be returned in new, unused, and resalable condition in its original packaging.
  3. Before returning any product, the buyer must obtain a Return Authorization Number (RA#) from a customer service representative. With your RA# you will receive a prepaid return shipping label.
  4. Orders returned without obtaining an RA# will be entitled to receive only "In-Store Credit" that can be used towards future purchases.
  5. Return orders are subject to a 20% restocking fees.
  6. All custom orders and hygienic items are non-returnable. Refer to the “Non-Returnable Items” section for further details.
  7. Returns will be reviewed and inspected before issuing credit. Please allow 3 to 4 weeks for processing. The credit will be applied to your original method of payment.
  8. If the return is the result of a defective product or shipping error, we will refund the entire purchase amount and return shipping costs.

Which products are Non-Returnable?

Due to the hygienic nature of some items, they are non-returnable. The items listed below are non-returnable:

  1. All hygienic items.
  2. Opened personal care items.
  3. Anything opened, used, or tried on.
  4. All customized items.
  5. Besides these, items that have the “non-returnable” phrase on the website.

We reserve the right to make adjustments due to errors, changing market conditions, product discontinuation or typographical errors in advertisements. Images on the site may not always reflect the actual product. Footrests or leg-rests are not included with wheelchairs unless specified.

How do I receive a return authorization number?

You can submit a return request by logging into your account. You will receive the Return Authorization Number (RA#) details in the email within 2-3 business days.

  • Login to your account
  • Go to “order history”
  • Click on “return order”
  • Fill out the return form and Submit it

If you do not have an email address, we will make other accommodations for RA# Details. Write the RA# on your label affixed to your package prior to shipment.

How long does it take to receive a refund?

Please allow 3 to 4 weeks to process the returns. Once the item is received, and inspected, your refund will be processed and automatically applied to your credit card or original method of payment.

Is there any Restocking Fees?

  1. 20% restocking fees will be applied.
  2. Outbound shipping cost is non-refundable.
  3. For orders that qualified for free shipping, $8.99 will be deducted from the refund if the product is returned.

Other Tracheal Care Accessories

{{'Buy ' + x.Name}}
{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}
Please enter your and your friend's email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
Submit Cancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close