Moog EnteraLite Infinity Enteral Feeding Pump is the first and only truly 100% mobile nutrition delivery system. Infinity Pump is in small size, portability, and ease of use, enabling patients of all ages to adhere to recommended feeding regimens and schedules to get the nutrition they need for living. Both pediatric and adult tube-fed patients have used it.

Why choose Infinity Pump?

  • Easy to learn and use with an intuitive design
  • Uninterrupted care while operating
  • No Annual Maintenance or Calibration
  • Washable Under Running Water

Moog Infinity Enteral Feeding Pump Benefits

Measures +/-5% Accuracy

Maintains ± 5% accuracy at any flow rate and when operated in any orientation. This allows and enables patients to comply exactly with prescribed feeding regimens.

Portable

Weighs less than 1 pound and is easily carried in a custom-designed carry pack for extended use, resulting in fewer limitations to a patient’s normal lifestyle, which may lead to increased feeding schedule compliance.

Easy-To-Use

Features an intuitive design and interface that can be quickly and easily mastered, allowing the caregiver to focus on other areas of care. The easy-to-load cassette allows for consistent use.

Rugged

Performs consistently under a wide variety of conditions. It does not require any regularly scheduled maintenance or calibration, and can be cleaned with warm soapy water.

 

What does EnteraLite Infinity Feeding Pump include?

  • Pump
  • A/C adapter charger
  • Pole clamp
  • Operators Manual

Enteralite Infinity Pump Manual & Guides

What to buy with Enteral Feeding Pump


Also available (separately):

How to use Enteralite Infinity Pump?

  1. If you are using the Safety Screw Connector or Spike set with a vented bottle or pre-filled bag, remove the protective cover from the tip, then insert the tip into the formula exit port of the container. Using the Safety Screw Connector set, secure the tip by tightly screwing threaded components together. If you are using the 500ml or 1200ml disposable set, hold the bag upright and pour in the enteral feeding solution. Then, close the cap securely.
    NOTE: Blenderized or aggressively mixed solutions may have foam. If using this type of solution, allow it to sit for 10 to 15 minutes before pouring into the bag. Settling the formula will reduce the chance of sounding an alarm due to air in the tubing.
  2. Remove the protective cover from the barbed adapter. If using a pole clamp, place the protective cover in the groove on the back of the clamp.
    NOTE: Remove all air from the bag and tubing with a carry pack. Continue to Step 3 for instructions on removing air. If the set hangs above the pump on an IV pole, you may skip Step 4.
  3. Turn the bag upside down and gently squeeze. Tilt bag as needed to evacuate air through tubing port.
  4. Gently pinch the teal-colored tubing below the drop symbol. Hold this position until the air dissipates from the tubing. Gently squeeze bag at the same time to assist fluid flow. If the fluid does not flow, the pinch pressure may be too strong.
    NOTE: Inside the teal-colored tubing, below the water drop symbol is the in-line occluder. The in-line occluder has an anti-free-flow valve. Pinching the tubing gently moves away from the in-line occluder, allowing fluid to flow. It is important only to pinch the tubing below the water drop symbol to avoid damaging the in-line occluder.
    NOTE: Be extremely careful to pinch tubing using only the flat, soft part of your finger. Do not use fingernails when pinching tubing; doing so may puncture the delivery set. If you suspect a punctured delivery set, please discard it and use a new set.
    NOTE: Air may also be removed from tubing using the primer pump feature.
  5. Loop silicone tubing around the pump wheel, stretching it lightly. Seat the cassette into the pump. Close the pump door.
    NOTE: When using the 1200ml set with the Mini Backpack, load the set into the back section of the pack and thread the cassette through the port in the bottom corner of the pack before loading the cassette into the pump.
  6. To turn the pump on, press and hold the ON/OFF key for 1.5. While the pump runs through a self-test, the display will light and an audible alarm will sound as the pump displays the nine-digit number three digits at a time for one second each. The display will then show the letter ‘R’ followed by a number, which is the software revision. Next, all segments of the display will show for 2-seconds. Verify that all display segments and symbols are active. The self-test is complete, and the pump will display the last programmed rate and be in pause mode. If any air is still in the tubing, continue to Step 7 to use the prime pump feature.
  7. Press and hold the PRIME key. The alarm will sound once, and the pump will begin pumping at the maximum rate of 600 ml/hr. The display will read “TO STOP, LET GO.” Once all air is removed from the tubing, release the key. The pump will stop, the display will revert to the last programmed rate, and the pump will be in pause mode.

Cautions:

  • It is important to keep the air sensor free of debris, including spilled fluids or food that may adhere to the sensor, and prevent the detection of air in the tubing.
  • Use a cotton swab to clean the pathways of the cassette receptacle. (Refer to the Operator’s Manual for further cleaning instructions).
  • When using a programmed dose, infinite dose, or interval feeding setting, the volume of food in the bag/bottle should be monitored throughout the feeding cycle to ensure the patient has received the appropriate dose.

How to clean Enteralite Infinity Feeding Pump?

Infinity Pump

Unplug the Infinity AC Adapter/Charger from the pump, and turn the pump off.

moog infinity pump

Rinse the pump by holding it under a stream of warm water. Pump may also be cleaned with standard dish soap and a nonabrasive sponge or soft cloth

Enteralite Infinity Pump

Use a cotton swab to clean the pathways of cassette and to remove any residue on the pump wheel roller pins.

Infinity Pump

Dry with a clean cloth. Make sure the Infinity pump is completely dry before plugging into an electrical outlet.

 

FAQs About Enteralite Infinity Feeding Pump

Can I use my own homemade, blenderized food in the Infinity pump?

Use only commercially-prepared feeding solutions formulated for pumps prescribed by a health care professional. Do not use homemade feeding solutions in the Infinity pump.

What are the Infinity Delivery Sets made of? Do they contain Latex?

Infinity Delivery Sets are made with materials that DO NOT contain the plasticizer DEHP or natural rubber latex.

Infinity Moog Enteral Feeding Pump Specifications

Particular Dimension
Size 4.05"H (10.3cm) x 5.65"W (14.4cm) x 1.95"D (4.9cm)
Weight 14.4oz (408gm)
Flow rate range 0.1 to 600ml/hr
Flow rate increment 0.1ml/hr from 0.1 to 10m/hr, 1ml/hr from 10 to 600ml/hr
Accuracy +/- 5%
Dose range 0.1ml to 3000ml or infinite dose
Dose increment 0.1ml from 0.1 to 10ml, 1ml from 10 to 3000ml
Battery Lithium Ion, 24 hour life @ 125ml/hr
Battery charge time 6 hours
Operating orientation Any
Maintenance No annual maintenance or calibration required

Enteral Feeding Pump Warranty

2-year warranty

Moog Infinity Pump Reviews

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close