MIC KEY 14FR Gastrostomy Feeding Tube Extension Sets With Enfit Connectors

Authorized Retailer Badge

Item 8140-14-1.7,8140-14-2.7 is on backorder and will be shipped once it is back in stock.

Options

Item# Description Pkg reward$ Price Blank
Item #: 8140-14-1.5
14 Fr, Stoma Length: 1.5 cm
Each
Each
reward$
$8.00
$228.56
$159.99
Item #: 8140-14-2.3
14 Fr, Stoma Length: 2.3 cm
Each
Each
reward$
$8.05
$268.23
$160.94
Item #: 8140-14-2.7
14 Fr, Stoma Length: 2.7 cm
Each
Each
reward$
$8.05
$230.04
$161.03
Item #: 8140-14-3.5
14 Fr, Stoma Length: 3.5 cm
Each
Each
reward$
$8.41
$280.32
$168.19
Item #: 8140-14-4.5
14 Fr, Stoma Length: 4.5 cm
Each
Each
reward$
$8.18
$272.54
$163.52

14FR MIC KEY Gastrostomy Feeding Tube Extension Sets With Enfit Connectors is a discreet and easy-to-conceal feeding tube suitable for almost everyone. The Gastrostomy Feeding Tube Extension allows patients to get the most out of life. It's made of medical-grade silicone and features a low-profile design.

Why choose MIC KEY Gastrostomy Feeding Tube Extension Sets?

  • Low-profile design
  • Sterile
  • Single use
  • Natural rubber, latex-free
  • Various sizes available

MIC-KEY Low-Profile Gastrostomy Feeding Tube Extension Sets Features

  • It has recessed distal tip design 
  • Proximal anti-reflux valve 
  • Secur-Lok extension set connector mechanism 
  • Radiopaque stripe

When to use MIC KEY 14FR Gastrostomy Feeding Tube?

The MIC-KEY Low-Profile Gastrostomy Feeding Tube is indicated for use in patients:


  • Who require long-term feeding
  • Who are unable to tolerate oral feeding
  • who are at low risk for aspiration, require gastric decompression and/or medication delivery directly into the stomach

What to buy with MICKey Extension Tubing


How to measure Mic-Key Stoma length?

Selection of the correct size MIC-KEY is critical for the safety and comfort of the patient. Measure the length of the patient’s stoma with the Stoma Measuring Device. The shaft length of the MIC-KEY selected should be the same as the length of the stoma. An inappropriately sized MIC-KEY can cause necrosis, buried bumper syndrome, and/or hypergranulation tissue.



  • Lubricate the tip of the Stoma Measuring Device with water-soluble lubricant.
  • Caution: Do not use mineral oil. Do not use petroleum jelly. 
  • Advance the Stoma Measuring Device over the guidewire, through the stoma, and into the stomach. Caution: Do not use force. 
  • Fill the Luer slip syringe with 5 ml of water and attach to the balloon valve. Depress the syringe plunger and inflate the balloon. 
  • Gently pull the device toward the abdomen until the balloon rests against the inside of the stomach wall. 
  • Slide the plastic disc down to the abdomen and record the measurement above the disc. 
  •  Add 4–5 mm to the recorded measurement to ensure the proper stoma length and fit in any position. Record the measurement. 
  • Using a Luer slip syringe, remove the water in the balloon. 
  • Remove the stoma measuring device. 
  • Document the date, lot number, and measured centimeter shaft length.


How to replace MIC-KEY Gastrostomy Feeding Tube?


  • Cleanse the skin around the stoma site and allow the area to air dry.
  • Measure the stoma length with the stoma Measuring Device.
  • Select the appropriate size MIC-KEY Gastrostomy Feeding Tube and prepare according to the instructions in the Balloon Verification section.
  • Lubricate the balloon tip with water-soluble lubricant and gently insert the MIC-KEY through the stoma into the stomach.
  • Ensure the external base is flush with the skin.
  • Using the 6 ml Luer slip syringe, inflate the balloon with sterile or distilled water per the Inflation Table.
  • Caution: Do not exceed 5 ml total balloon volume inside the 12 Fr balloon. Do not inject contrast into the balloon. Do not use air or saline. Caution: Do not exceed 10 ml total balloon volume in 14 Fr or larger feeding tube balloons. Do not inject contrast into the balloon. Do not use air or saline.
  • Clean the residual fluid or lubricant from the Feeding Tube and stoma.
  • Verify proper Feeding Tube position according to the instructions in the Verify MIC-KEY Position and Patency section above.


Mic-KeyFeeding Tube User Manual

Customer Reviews

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close