Get 10% OFF*, Use Code: HPDIS10

Day
:
:
Online since 2002 |   866-316-0162

View product option

Extricare 3600 Negative Pressure Wound Therapy Pump

Product Option

6.7" L X 4.3" D X 5.1" H

SKU EC3600
$2,500.00 Each
Request quote

Extricare 3600 Negative Pressure Wound Therapy Pump is reliable and effective. The Extricare 3600 pump offers a rechargeable and long-lasting battery, simple-to-use software, and smart alarms, making it a perfect fit for a facility or transitioning a patient home. It is a portable, battery-powered pump in hospitals, wound care centers, and other medical facilities.

Highlights of Extricare 3600 Wound Vacuum Pump

  • Versatile: High-capacity, high-flow pump, offers maximum care.
  • Powerful: Long lasting rechargeable battery may last for up to 24 hours of treatment
  • Easy to Use: Simple operation and user-friendly interface.

Autoship

$2,475.00 $3,125.00

20% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $125.00 in HPFY rewards

One-time purchase

$2,500.00 $3,125.00

Earn $125.00 in HPFY rewards
For Assistance 877-278-6039

Features of Extricare 3600 Wound Vacuum Pump

  • Rotatable back mount for securing to bed-side or poles
  • Fitted carrying case for portability
  • Smart mute alarms continuous and intermittent modes
  • Quickly set pressure from 40-200mmHg
  • Set pressure & actual pressure display for identifying leak location
  • Used in conjunction with the anatomically fitted line of wound dressings
  • Utilizes an optional 400cc or 1000cc canister capacity
  • Input:
    - 100-240 V
    - 50/60 Hz
    - 1.5 Amp. 

Extricare 3600 NPWT Pump User Manual

Instructions for Use of Extricare 3600 Wound Vacuum Pump

  • To install canister: First, line up the 2 tabs on the bottom of the canister to the notches on the bottom of the Extricare 3600 device, and then press the canister clip into place.
  • Power ON/OFF: To power on the device, flip the Power Switch located on the device's back panel.
  • Pressure Setting Controls: To change the pressure, press the Up and Down buttons and set them to the desired pressure. The pressure changes in increments of 5 mmHg with a range of 40 mmHg to 200 mmHg.
  • Mode (M): Press the Mode Button to switch between continuous or intermittent. In continuous mode, the device will continuously operate at the set pressure. In intermittent mode, the device will operate for 5 min. at the set pressure, and then for 2 min. at 20 mmHg, and then repeat the cycle.
  • Start/Stop Treatment: To start or stop treatment, press the Start/Stop Button for 2 seconds.
  • Lock/Unlock Device: The device will lock automatically if there is no button input for 3 min. To unlock the device, press and hold the MODE and Start/Stop buttons for 2 seconds. To manually lock the device, press and hold the Mode and Start/Stop buttons for 2 seconds.
  • Rail Clamp: To use the rail clamp, insert the clamp board firmly into the socket at the back of the device (choose vertical for bedside clamp or horizontal for IV poll clamp). Unscrew the clamp (main black knob) to make space to secure the clamp to the poll (or bed). Screw clamp onto poll or bed. Make sure the clamp is tight, and the pump is secure.
  • Recharging Device: To recharge the device, use the charger included with the Extricare3600. The charging port is located on the left side of the device. To ensure charging, turn on the pump and make sure the power adapter icon is displayed.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close