Get 15% Off $50*, Code: HP15

Day
:
:
Online since 2002 |   866-316-0162

View product option

Bard Touchless Plus Unisex Coude Tip Intermittent Catheter Kit - 1100cc Collection Bag

Brand: BARD INC SKU: 4A8116
Authorized Retailer
Product Option

16FR

SKU 4A8116
$4.39 Each

14FR

SKU 4A8114
$4.49 Each

14FR

SKU 4A8114
$222.99 50/Pack
$4.46 Each
Request quote

Bard Touchless Plus Unisex Coude Tip Intermittent Catheter With 1100cc Collection Bag is a closed system kit designed for sterile intermittent catheterization and offers a pre-lubricated catheter with patented finger guide. The unique closed system helps to reduce the risk of urinary tract infections and the risk of cross-contamination. Touchless Plus Unisex Coude Tip Intermittent Catheter provides patient and caregiver an increased level of control and convenience.

Touchless Plus Coude Tip Intermittent Catheter Attributes:

  • Latex-free
  • Insertion Tip
  • Catheter Control Guide
  • Catheter Cap
  • Pre-lubricated Catheter
  • Contains a Vinyl Urethral Catheter
  • Large 1100cc collection bag

Autoship

$3.51 $7.05

20% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $0.22 in HPFY rewards

One-time purchase

$4.39 $7.05

Earn $0.22 in HPFY rewards

Features of Touchless Plus Intermittent Catheter

  • Insertion tip:
    - Correctly positions the catheter in the urethra to help reduce UTIs
  • Catheter control guide:
    - Allows control of catheter insertion with the touch of a finger
  • Tapered neck design:
    - Decreases cuts and scrapes associated with sharp corners
  • Catheter cap:
    - Has pull ring for easy removal
  • Pre-lubricated catheter:
    - Reduces discomfort during insertion
  • Large 1100cc:
    - Collection bag is durable, virtually eliminating the risk of leaks

More On Touchless Plus Intermittent Catheter

Warning:

  • This is a single use device
  • Do not resterilize any portion of this device
  • Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of patient

Instructions for Use:

  • Preparing for Catherization
    - Open kit and remove contents
  • Male/Female Catherization
    - Remove cap from insertion tip while squeezing tabs
    - Save cap for closing the bag
    - Slide the catheter halfway into the insertion tip
    - Male: Prepare the male urethral meatus and the surrounding area with povidone iodine swabs.
    Female: Prepare the female urethral meatus by holding the outer labia apart and prep the urethral meatus and surrounding area with povidone-iodine swabs
    - Male: Holding the penis, advance the insertion tip into the urethra no further than the flange base
    - Female: Spread the inner labia, advance the insertion tip into the urethra no further than the flange base
    - Release the inner labia
    - Place the non-dominant hand on the finger control guide to stabilize catheter in urethra
    - With the dominant hand, grasp catheter through bag approximately 1" below the finger control guide and push catheter into urethra
    - The catheter should be introduced by short, repetitive pushing motions
    - Repeat motions until catheter reaches bladder and urine starts to flow
    - Allow urine to flow freely, making certain the catheter guide is elevated at least 4" above lower portion of the bag
    - Allow flow until bladder is empty or until bag is filled

Precaution:

  • It is recommended that the collection bag be held
  • The catheter could possibly separate from the collection bag when urine increases weight of the bag
  • Withdraw the catheter from the urethra
  • Remove the remaining portion of the catheter from the collection bag by pulling it through the insertion tip
  • Note:
    - The catheter is designed to pass through the insertion tip
    - The filled collection bag may be closed by replacing the cap over the insertion tip
    - Make sure the cap snaps on securely 
    - Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations

Specimen Collection:

  • To collect a specimen, obtain a sample cup/tube and alcohol wipe
  • Remove guide tip by pulling tab(s) upward from bag
  • Wipe port with alcohol
  • Pour specimen through port at top of bag into cup/tube

Drainage Bag:

  • Remove insertion tip by pulling tab(s) upward from bag
  • Drain urine through port at top of bag

Specification

Particulars Specifications
Catheter Tip Coude Tip
Catheter Material Vinyl
Gender Unisex
Catheter Coating Hydrophilic
Catheter Style Coated Catheters
Catheter French Size 14FR

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close