A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff

Brand/Manufacturer: A&D MEDICAL

A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff is easy to use and comes standard with just the right number of features. 15 memory recall provides ample storage for home use or while traveling. Systolic, diastolic and pulse rate are all shown simultaneously for easy review. Irregular Heartbeat Detection also comes standard. This key feature alerts the user to the presence of an irregular heartbeat while still providing an accurate reading.

Features

  • A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff features speed and accuracy at the touch of a single button
  • One of our most efficient devices
  • When using alkaline batteries a user can expect approximately 700 readings before having to change batteries
  • A battery life indicator appears on the screen preventing any surprises
  • SlimFit cuff, covering arm circumferences of 9" – 14.6" (23 – 37 cm) is easy to use and comfortable
  • Pressure Rating Indicator
    - Providing a snapshot of the users blood pressure classification according to the US JNC7 guidelines
  • Irregular Heartbeat Detection
    - Alerts the user to the presence of an irregular heartbeat while still providing an accurate reading
  • SimFit Cuff
    - A latex and metal free cuff design
  • Click Here For User Manual
  • Click Here For Instruction Manual

More Information

  • Instructions
    - To obtain an accurate reading, it is important to use the correct cuff size
    - A cuff that is too large will produce a reading that is lower than the correct blood pressure, a cuff that is too small will produce a reading that is higher than the correct blood pressure
  • Precautions
    - Precision components are used in the construction of this device
    - Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided
    - Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent
    - Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff
    - Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as such treatment may shorten the life of the components
    - The device and cuff are not water resistant
    - Prevent rain, sweat and water from soiling the device and cuff
    - Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, X-ray or other devices with strong electrical fields
    - When reusing the device, confirm that the device is clean
    - Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations
    - Do not modify the device. It may cause accidents or damage to the device
    - To measure blood pressure, the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery. This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively
    - Any pain, numbness, or red marks will disappear with time
    - People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid medical problems
    - Do not self-diagnose the measurement results and start treatment by yourself
    - Always consult your doctor for evaluation of the results and treatment
    - Do not apply cuff on an arm with other medical equipment attached
    - Neither equipment may function properly
    - Do not apply the cuff on an arm with an unhealed wound
    - Do not apply the cuff on an arm receiving an intravenous drip or blood transfusion
    - It may cause injury or accidents
    - Do not use the device where flammable gases such as anesthetic gases are present. It may cause an explosion
    - Do not use the device in highly concentrated oxygen environments, such as a highpressure oxygen chamber or an oxygen tent
    - It may cause a fire or explosion
    - Do not excessively bend or squeeze the air hose
  • Maintenance
    - Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged
    - It is generally recommended to have the monitor inspected every 2 years to ensure proper functioning and accuracy

Specification

ParticularsSpecifications
Display34.9 x 54.2mm (view area)
MemoryLast 15 measurements
PressurizationAutomatic, using micropump
DeflationConstant air release valve system
TypeOscillometric
AccuracyPressure: ±3 mmHg. Pulse: ±5%
Power Source4 x 1.5v batteries (R6P, LR6 or AA)
Recommended Operating Environment50ºF to 104ºF (+10ºC to +40ºC). 800 to 1060hPa
Recommended Storage Environment-4ºF to 140ºF (-20ºC to +60ºC)
ClassificationInternally powered ME equipment (Supplied by batteries). Continuous operation mode
Weight8.1 oz. (230g) without batteries
Pressure RangePressure : 0 - 299 mmHg
Systolic pressure: 60 - 279 mmHg
Diastolic pressure: 40 - 200 mmHg
Pulse: 40 - 180 beats / minute
No. of MeasurementsApprox. 700 times LR6 (alkaline batteries)
Approx. 200 times R6P (manganese batteries)
With pressure value 180 mmHg, room temperature 23 °C

Warranty

  • Device: 5 years (when used six times a day)
  • Cuff: 2 years (when used six times a day)

Customer Reviews

+=
Question

ItemName - now     04/15/2021

ItemQuestion
  Your question will show here once it will get approved.
Answer

UserName - now     04/15/2021

UserAnswer
  Your Answer will show here once it will get approved.

{{x.Heading}}

{{x.ShortDescription}} ...

What is HPFY’s return policy?

Customer satisfaction is our top priority. We stand behind our products. If the merchandise you received is defective or not what you expected it to be, and you wish to return the item, please submit a return request in the My Account section of our website, contact our Customer Service department at (866) 316-0162 / (203) 616-2850 or email us.

  1. Merchandise must be returned within 30 days of the receipt of your order. Returns are not accepted after 30 days.
  2. Items (including parts and accessories) must be returned in new, unused, and resalable condition in its original packaging.
  3. Before returning any product, the buyer must obtain a Return Authorization Number (RA#) from a customer service representative. With your RA# you will receive a prepaid return shipping label.
  4. Orders returned without obtaining an RA# will be entitled to receive only "In-Store Credit" that can be used towards future purchases.
  5. Return orders are subject to a 20% restocking fees.
  6. All custom orders and hygienic items are non-returnable. Refer to the “Non-Returnable Items” section for further details.
  7. Returns will be reviewed and inspected before issuing credit. Please allow 3 to 4 weeks for processing. The credit will be applied to your original method of payment.
  8. If the return is the result of a defective product or shipping error, we will refund the entire purchase amount and return shipping costs.

Which products are Non-Returnable?

Due to the hygienic nature of some items, they are non-returnable. The items listed below are non-returnable:

  1. All hygienic items.
  2. Opened personal care items.
  3. Anything opened, used, or tried on.
  4. All customized items.
  5. Besides these, items that have the “non-returnable” phrase on the website.

We reserve the right to make adjustments due to errors, changing market conditions, product discontinuation or typographical errors in advertisements. Images on the site may not always reflect the actual product. Footrests or leg-rests are not included with wheelchairs unless specified.

How do I receive a return authorization number?

You can submit a return request by logging into your account. You will receive the Return Authorization Number (RA#) details in the email within 2-3 business days.

  • Login to your account
  • Go to “order history”
  • Click on “return order”
  • Fill out the return form and Submit it

If you do not have an email address, we will make other accommodations for RA# Details. Write the RA# on your label affixed to your package prior to shipment.

How long does it take to receive a refund?

Please allow 3 to 4 weeks to process the returns. Once the item is received, and inspected, your refund will be processed and automatically applied to your credit card or original method of payment.

Is there any Restocking Fees?

  1. 20% restocking fees will be applied.
  2. Outbound shipping cost is non-refundable.
  3. For orders that qualified for free shipping, $8.99 will be deducted from the refund if the product is returned.

Also available:

{{'Buy ' + x.Name}}
{{x.Name}}
${{ x.OurPrice | currency: "" : 2}}
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
Submit Cancel
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close