Covidien Kendall Entriflex Nasogastric Feeding Tube With Safe Enteral Connection With Stylet
Covidien Kendall Entriflex Nasogastric Feeding Tube With Safe Enteral Connection With Stylet

Covidien Kendall Entriflex Nasogastric Feeding Tube With Safe Enteral Connection With Stylet

Brand/Manufacturer: COVIDIEN/MEDTRONIC
Save

Covidien Kendall Entriflex Nasogastric Feeding Tube With Safe Enteral Connection With Stylet is designed for nasogastric and naso duodenal feeding with a slimmer, lighter weighted tip for easier insertion. The feeding port is incompatible with luer lock or IV connections, reducing the risk of accidental connection or infusion.

Item #DescPkgRewardPrice 
8884720858 8FR x 43", 3gm Each $0.17
$30.50
$16.99
8884720858 8FR x 43", 3gm 10/Pack $1.90
$230.50
$189.99
8884720825 8FR x 36", 3gm Each $0.17
$30.65
$16.99
8884720825 8FR x 36", 3gm 10/Pack $1.68
$220.60
$167.99
8884721088 10FR x 43", 5gm Each $0.17
$30.50
$16.99
8884721088 10FR x 43", 5gm 10/Pack $1.70
$230.50
$169.99
8884720855 8FR x 55", 5gm 10/Pack $2.60
$354.99
$259.99
8884721255 12FR x 55", 5gm 10/Pack $2.60
$354.99
$259.99
8884721055 10FR x 55", 5gm 10/Pack $2.60
$354.99
$259.99
8884721252 12FR x 43", 5gm Each $0.17
$30.50
$16.99

Features

  • Covidien Kendall Entriflex Nasogastric Feeding Tube With Safe Enteral Connection With Stylet to address the 2006 JCAHO Tubing Misconnections Sentinel Alert
  • Coated with Hydromer hydrophilic lubricant which allows for easy removal of stylet once tube has been placed
  • Radiopaque polyurethane material is easily detectable via X-Ray or fluoroscope
  • Y-Port connectors side port allows medication or fluid delivery without having to disconnect feeding adapter
  • Centimeter (cm) markings allow for ease of placement and tracking of tube migration
  • Weighted feeding tubes with and without flow through stylets
  • Purple feeding port indicates nutritional port, not I.V. access
  • Comes with Rigid Outlet Port, Weighted Tip and Stylet 
  • MRI conditional once stylet is removed
  • DEHP-free

Customer Reviews

Questions & Answers


 
 
question image
What is the MRI contions for scanning this device
Michele - 11/30/2016 10:20:57 AM
facebooktwittergplus
answer image
You have to remove Covidien Kendall Entriflex Nasogastric Feeding Tube while doing MRI.
Customer Care - 12/1/2016 7:10:43 AM
question image
Thank you for your reply. Are the weighted pellets made from Polyurethane as well as they appear metallic?
Adelene Choo - 6/22/2016 2:53:40 AM
facebooktwittergplus
answer image
Thank you for contacting customer care service.
It is coated with 
Customer Care - 7/11/2016 1:54:30 AM
answer image
Thank you for contacting customer care service. 
 It is coated with Hydromer hydrophilic lubricant.
Customer Care - 7/7/2016 1:21:04 AM
question image
What material is the 3g weighted tip made out of?
Adelene Choo - 6/21/2016 8:43:37 PM
facebooktwittergplus
question image
How long can this tube be left in?
JoAnna - 11/9/2015 9:32:44 PM
facebooktwittergplus
answer image
Thank you for reaching out to us. Covidien Kendall Entriflex Nasogastric Feeding Tube with Safe Enteral Connections can be dwell in the patient up to 30 days with proper care and maintenance.
Customer Care - 11/12/2015 12:58:23 AM