Get 15% Off $50*, Code: HP15

Day
:
:
Online since 2002 |   866-316-0162

View product option

Drive Chad CGA 870 Oxygen Regulator

Brand: DRIVE MEDICAL SKU: CH4808-L-BLUE
Authorized Retailer
Product Option

0-8 LPM, Click Style Blue Regulator

SKU CH4808-L-BLUE
$64.39 Each

0-15 LPM, Click Style Blue Regulator

SKU CH4815-L-BLUE
$66.59 Each
Request quote

Drive Chad CGA 870 Oxygen Regulator offers a multitude of liter flow options. The Barb Outlet will connect to a humidifier or an adapter is needed to connect directly to a cannula. The ergonomic T-handle makes tightening quick and pain-free. A sleek blue finish gives this oxygen regulator some flare.

Drive Chad CGA 870 Oxygen Regulator Highlights:

  • 20-micron
  • Barb Outlet
  • Sleek blue finish
  • Ergonomic t-handle
  • Sintered-bronze inlet filter

$90.15

Total: $64.39

Earn $3.22 in HPFY rewards

Features of Drive Chad CGA 870 Oxygen Regulator

Oxygen Flow Control Regulators:


  • Pressure reducing devices which lower oxygen pressure from a cylinder to levels that can be safely used by the user
  • Intended for the administration of oxygen to patients who need increased oxygen levels to improve their breathing conditions
  • In addition, some models may be used in emergency situations
  • In an emergency situation, be sure to contact a physician or EMS immediately
  • 100% quality QC tested in the USA
  • 20-micron, sintered-bronze inlet filter
  • All flows tested to an accuracy within +/- 15% tolerances
  • Ergonomic t-handle for easy tightening
  • FDA recommended Viton and brass seal washers
  • Inlet pressure:
    - 200-3000 PSI
  • Outlet pressure:
    - 50PSI

More About Drive Chad CGA 870 Oxygen Regulator

  • Use:
    - Be sure the oxygen regulator is in the "off" position by rotating the knob counterclockwise to the "0" position.
    - For safety, be sure you are not directly in front of or behind the regulator when opening the cylinder valve.
    - Slowly turn the cylinder valve on (counterclockwise), about one full turn.
    - If you can hear a hissing sound, there is a leak in the system. Turn the cylinder off and turn the regulator on to relieve any built-up pressure.
    - Try tightening the regulator to the cylinder and opening the cylinder again. If this does not help, shut the system down again and contact a service representative.
    - Never attempt to repair a regulator or cylinder yourself.
    - Adjust the flow rate setting by turning the knob clockwise until the desired setting shows through the window.
    - If the cylinder pressure falls below 300 PSI, you should exchange the cylinder for a full one
    - To turn off the system, close the cylinder valve, wait for oxygen to flow out of the regulator, and turn the regulator to the "0" position.
    - Never try to remove the drive oxygen regulator unless the cylinder is off and pressure has been relieved.

  • Set Up:
    - Inspect and install the cylinder using instructions from qualified personnel.
    - Be sure to purge the cylinder valve seat of debris.
    - Inspect the regulator for oil or grease. If these are visible, do not use the regulator.
    - Be sure the sealing washer is in place in the yoke inlet.
    - Slip the yoke over the cylinder post and fit the pins into the holes on the cylinder valve. The pins should fit easily into these holes.
    - Turn the t-handle clockwise until the screw point is seated in the dimple on the cylinder valve.
    - Be sure the regulator is tightened snugly onto the cylinder. Attach the oxygen supply tubing to the barbed outlet connection.

  • Warnings:
    - Federal law restricts this device to use by or on order of a physician. Only use as prescribed by a physician.
    - This CGA 870 oxygen regulator should only be used on patients who are breathing; do not use to resuscitate non-breathing patients.
    - Do not use oil, grease, or any other flammable material. Keep out of reach of children.
    - Do not smoke in an area where oxygen is in use.
    - Do not use this CGA 870 regulator unless you have been trained in its proper use or are under the supervision of someone trained in its use.
    - If the pressure relief valve on the underside of the regulator begins to vent oxygen, turn off the system and remove the unit until it can be serviced.

Drive Chad CGA 870 Oxygen Regulator Warranty

3 Years Limited Warranty

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close