Atos Medical Provox2 Voice Prosthesis
Atos Medical Provox2 Voice Prosthesis

Atos Medical Provox2 Voice Prosthesis

Brand/Manufacturer: ATOS MEDICAL
Save
Authorized Retailer Badge

Atos Medical Provox2 Voice Prosthesis is a low-resistance, indwelling silicone voice prosthesis that can be inserted immediately after primary or secondary TE puncture, without the need for temporary stenting. It is an anterograde manner using the single-use insertion tool.

Item #DescPkgRewardPrice 
7216 4.5mm Each $4.20
$515.85
$419.99
7217 6mm Each $4.20
$515.85
$419.99
7218 8mm Each $4.20
$515.85
$419.99
7219 10mm Each $4.20
$515.85
$419.99
7221 12.5mm Each $4.20
$515.85
$419.99
7224 15mm Each $4.20
$515.85
$419.99

Features

  • Atos Medical Provox2 Voice Prosthesis features low airflow resistance
  • Slightly concave shape of the tracheal flange of the Provox2 helps ensure a proper fit even if the fistula size changes slightly
  • Stable flange facilitates immediate confirmation of whether the device is correctly in place
  • Easy maintenance
  • Safe placement
  • Detectable in x-ray
  • High success rate
  • Note: Prescription required and can be faxed to 1.203.616.2851

Customer Reviews

Questions & Answers


 
 

Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image

I use a INHEALTH TEC .VOICE. Prostheses  which has to be replaced about every 12 months  does the Provox  2 last any longer then 12 months

ken - 12/29/2016 9:39:52 AM
facebooktwittergplus
answer image
Biofilm (Bacteris and candida) overgrowth will occur in almost all patients. This will eventually cause material degradation, leakage through the prosthesis, or other incompetence of the valve. Radiotherapy, salivary content gastroesophageal reflux and dietary habits may influence how rapidly biofilm forms.  It is therefore not possible to predict device lifetime.
Laboratory testing shows that in the absence of bacteria and yeasts the device will maintain its integrity for 12 months of simulated use.  Usage beyond this limit is under the sole discretion of prescriber.
Indications for replacement includes leakage through or (partial) blockage of the valve, degradation of the material, or medical indications such as problems with the puncture tract.
Customer Care - 1/31/2017 12:04:43 PM