Free Shipping* Above $50 Code: HPFY50

Day
:
:
Online since 2002 |   866-316-0162

View product option

Graham Field John Bunn Vacutec 800 EV2 Aspirator

Authorized Retailer

Graham-Field Vacutec 800 EV2 Aspirator is a professional medical suction device with a maximum vacuum of 560 mmHg. The unit comes with an 800cc collection bottle designed to be easy to use and dependable. Ideal for daily use by a single patient. It has an easy-to-read gauge, a flow regulator knob that is easy to turn, and suction cup feet for stable operation. It has an automatic shut-off feature and is suitable for most homecare suction applications.

Why choose Vacutec 800 EV2 Aspirator?

  • Low level noise
  • Designed for single patient
  • Easy-to-read gauge
  • Power Consumption - 60W

Warning WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Features of Graham Field Vacutec 800 EV2 Aspirator

What to buy with Vacutec 800 Aspirator


How to Operate Graham Field 800 EV2 Aspirator?

  • Make sure the ON/OFF switch located on the side of the unit is in the OFF position. Plug the aspirator into a properly grounded power outlet.
  • Switch the ON/OFF switch to I position (ON); the unit will start running.
  • Adjust the vacuum level from 0 to 560 mmHg by turning the vacuum adjust knob (clockwise to increase vacuum and counter-clockwise to decrease vacuum). Refer to the vacuum gauge while setting the desired level of vacuum. To accurately read the gauge, block the patient end of the hose or cap off the collection bottle and allow the gauge to reach a stable vacuum reading.
  • Position the suction tubing appropriately for patient and begin suction Therapy
  • When the liquid in the collection bottle reaches the safe full level (800 cc), the float shut-off will activate automatically and suctioning will stop.
  • Switch the ON/OFF switch to the OFF position to shut off the suction motor
  • Unplug the aspirator when not in use.
  • Remove the liquid from the collection bottle after the motor stops turning completely.
  • Switch the ON/OFF switch to the ON position and start to run the aspirator again.


Note:

  • If the unit sustains a severe drop, the validity of the gauge must be checked. Inspect the float shut-off to ensure it still functions properly when the liquid in the collection bottle reaches the safe full level.
  • Always transport unit with vacuum adjust knob rotated fully clockwise in case the unit is dropped.

Caution:

  • When automatic float shut-off is activated, empty the contents of the collection bottle immediately. Further suction could cause damage to the vacuum pump.
  • Should fluid be aspirated back into the unit, contact your Graham-Field authorized distributor for a detailed inspection, as the vacuum pump may have been damaged.


Vacutec 800 EV2 Aspirator User Manual


How to clean John Bunn Vacutec Aspirator Suction Unit?

  • Clean Collection Bottle:
    • Turn off the aspirator, allow vacuum to drop, then disconnect AC power source.
    • With the collection bottle still in the holder, remove the collection bottle lid. The bottle can now be taken out of the holder to be emptied. NOTE: Empty the collection bottle immediately after each use.
    • Clean the collection bottle after each use by using one of the following three methods:
      • Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water . Then wash in one part vinegar to three parts hot water solution. Rinse with hot tap water and air dry .
      • Wash with rubbing alcohol and air dry.
      • Wash with a commercial (bacterial-germicidal) disinfectant; follow disinfectant manufacturer recommended instructions and dilution rates carefully.

  • Clean Aspirator and Collection Bottle Lid:
    • Disconnect the aspirator from all external power sources.
    • Wipe the aspirator housing and collection bottle lid with a clean cloth and any commercial (bacterial-germicidal) disinfectant.
      Caution: Do not submerge unit in water as this will result in severe damage to the vacuum pump.

  • Clean Tubing:
    • Disconnect the tubing from the unit.
    • Rinse the tubing thoroughly after every use by running hot tap water through it, followed by a solution of one part vinegar to three parts hot water.
    • Rinse with hot tap water and air dry.
    • Keep the outer surface of the tubing clean by wiping with a clean, damp cloth.


Vacutec 800 EV2 Specification

Particulars Dimensions
Width 4.9"
Depth 15.3"
Height 10"
Weight 11.6 lbs
Power Requirements 115 VAC, 60Hz
Vaccum Range 0 - 560 mm Hg
Power Consumption 60 watts
Operating Flow 0-40 LPM
Bacteria Filter HEPA
Operating Temperature and Humidity 32ºF to 104ºF (5º to 40º C)
Operating Humidity 95% RH

Warranty

2 Year limited warranty

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Vacutec 800 EV2 Reviews

More Suction Machines and Aspirators

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close