Graham Field John Bunn Vacutec 800 EV2 Aspirator
Graham Field John Bunn Vacutec 800 EV2 Aspirator

Graham Field John Bunn Vacutec 800 EV2 Aspirator

  • Made in USA

Graham-Field Vacutec 800 EV2 Aspirator is designed for single patient, everyday use. It has a low level noise at less than 55 decible. Comes with easy-to-read gauge, easy-to-turn flow regulator knob and with a suction cup feet for stable operation. Easy-to-read gauge and easy-to-turn flow regulator knob are the added features. Provided with automatic shut -off and designed for most homecare suction applications.

Item #DescPkgPrice 
JB0112-016 Vacutec Ev2 Blue & Silver Each $250.60 $159.90

Features

More Information

Federal law (USA) restricts this device to sale by or on the order of a physician. This product should not be used unless the operator has been instructed by a qualified healthcare professional. This device is for use by one person only; in order to avoid infection, do not share it.
SAFETY INFORMATION:
- DANGER: Indicates an imminent hazard situation that, if not avoided, will result in death or serious personal injury.
- WARNING: Indicates a potential hazard situation that, if not avoided, could result in death or serious personal injury.
- CAUTION: Indicates a potential hazard or unsafe practice that, if not avoided, could result in product or property damage.
DANGER: To reduce the risk of electrocution:
1. Do not use while bathing.
2. Do not place or store product where it can fall or be pulled into a tub or sink.
3. Do not place in or drop into water or other liquid.
4. Do not reach for a product that has fallen into water . Unplug immediately. WARNING: To reduce the risk of burns, electrocution, fire or personal injury:
1.Close supervision is necessary when this product is used by , on, or near children or those who need extra care.
2.Use this product only for its intended use as described in this guide.
3.Never operate this product if:
a. It has a damaged power cord or plug.
b. It is not working properly.
c. It has been dropped or damaged.
d. It has been dropped into water.
4. Return the product to a Graham-Field authorized distributor for examination and repair.
5. Keep the power cord away from heated surfaces.
6. Never use while drowsy or asleep.
7. This device is for use by one person only; in order to avoid infection, do not share it.
SPECIFIC WARNINGS:
- TO REDUCE THE RISK OF ELECTRICAL SHOCK OR PERSONAL INJURY, DO NOT DISASSEMBLE THIS UNIT. Disassembly or attempted repairs, if accomplished incorrectly, can create electrical shock hazard. Only qualified technicians should perform servicing of this aspirator. Contact your Graham-Field authorized distributor for service.
- DANGER: The John Bunn Vacutec™ 800 EV2 Aspirator is a vacuum suction device intended for the collection of nonflammable fluid materials in medical applications only . Improper use during medical applications can cause injury or death.
AC POWER SOURCE:
- CAUTION: The Model JB0112-016 uses a power supply allowing operation on AC voltage (115 VAC, 60 Hz). However, the correct power source must be used to connect to adaptable wall power. Before use, check the specification label on the side of the aspirator to ensure that the voltage and current indicated on the unit match the voltage and current available.
SETUP WARNINGS:
1. This device is equipped with a three-prong (grounding) plug for protection against possible shock hazard. Plug only into a properly grounded three-prong wall receptacle. Where a two-prong wall receptacle is encountered, contact a licensed professional to have the two-prong receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. DO NOT modify the plug in any way.
2. If an extension cord must be used, use a three-conductor cord with the same or higher electrical rating as the aspirator cord, with ground, properly wired, in good electrical condition, and keep it as short as possible.
3. Locate all cords so that they will not be stepped on, tripped over , or otherwise subjected to damage or stress.
MAINTENANCE:
- DANGER: Electric shock hazard Do not attempt to open or remove the suction cabinet. If service is required, contact your Graham-Field authorized distributor. Opening or tampering with the unit will void the warranty

Specification

Particulars Dimensions
Width 4.9"
Depth 15.3"
Height 10"
Weight 11.6 lbs
Power Requirements 115 VAC, 60Hz
Vaccum Range 0 - 560 mm Hg
Power Consumption 60 watts
Operating Flow 0-40 LPM
Bacteria Filter HEPA
Operating Temperature and Humidity 32ºF to 104ºF (5º to 40º C)
Operating Humidity 95% RH

Warranty

2 Year limited warranty

Customer Reviews

Questions & Answers


 
 
question image
Hi I am very interested in this item, however I need to know how loud it is while in use.
Al - 4/9/2016 5:18:51 PM
facebooktwittergplus
answer image
Thank you for reaching out to us. The sound level of This unit is < 55 dBA
Customer Care - 4/11/2016 1:58:00 AM
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close