Performa Electrotherapy and Ultrasound Units

Authorized Retailer

Performa Electrotherapy and Ultrasound Units are advanced electrotherapy and ultrasound systems with a menu-driven, color touchscreen interface that groups and displays clinical protocols intuitively, leading physicians step-by-step to assure the best therapeutic treatment. Physical therapy, therapeutic therapies, and athletic training can all benefit from a range of ultrasound and electrotherapy devices.


Performa Electrotherapy and Ultrasound Units Features

  • Generate Dual Ultrasound Includes
    - A comprehensive library of protocols
    - Patient kill switch
    - Both pulsed and continuous modes
    - Soundhead coupling
    - Capability to toggle between W and W/cm²
    - (1) 5cm² soundhead
    - (1) 1cm² soundhead
  • Stimulate 4 Channel Stim Includes
    - (2) sets of lead wires
    - Patient kill switch
    - Interferential Stimulation Premodulated (2 Pole IFC)
    - Interferential Stimulation Traditional (4 Pole IFC)
    - Biphasic (TENS)
    - Neuromuscular Stimulation (NMS)
    - Russian Stimulation
    - High Volt Pulsed Current
    - Microcurrent, and pre-loaded with “RAAS” Protocol - Rapid Agonist Antagonist Sequencing
  • Combind Duo 2 Channel Combo Includes
    - (1) set of lead wires
    - (1) combo lead wire
    - (1) 5cm² soundhead
    - Patient kill switch
    - Electrotherapy waveform rationale
    - Appropriate parameter settings
    - Electrode placement guide
  • Units are sleek, user-friendly, and feature an ergonomic design for tabletop or therapy cart use
  • Large, easy-to-read, color LCD display with touch screen interface for easy, step-by-step treatments

What to buy with Stim/Ultrasound Therapy Units


Electrotherapy/Ultrasound Unit Indications & Contradictions


Electrotherapy Indications (for TENS, EMS, NMS, NMS Burst, Russian (RUSS), High Voltage Pulsed Current (HVPC), Interferential, Pre-modulated Interferential, and Microcurrent waveforms)

  • Pain relief of chronic intractable pain
  • Pain associated with post-traumatic or postoperative conditions
  • Relaxation of muscle spasms 
  • Prevention or retardation of disuse atrophy
  • Increase local blood circulation
  • Muscle re-education
  • Maintaining or increasing range of motion
  • Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis (do not stimulate calf muscle simultaneously)

Electrotherapy Contradictions


  • This device should not be used for symptomatic pain relief unless etiology is established or unless a pain syndrome has been diagnosed.
  • This device should not be used on patients with demand-type cardiac pacemakers.
  • This device should not be used over cancerous lesions.
  • Electrode placements that apply current to the carotid sinus region (anterior neck) must be avoided
  • Electrode placements that apply current transcerebrally (through the head) must be avoided
  • Electrode placements that apply current transthoracically (the introduction of electrical current into the heart may cause cardiac arrhythmias) must be avoided
  • Stimulation should not be applied over a swollen, infected, inflamed area or skin eruptions (e.g. phlebitis, thrombophlebitis, varicose veins, etc.)
  • Other contraindications are patients suspected of carrying serious infectious disease and/or disease where it is advisable, for general medical purposes, to suppress heat or fevers
  • Safety has not been established for the use of therapeutic electrical stimulation during pregnancy

Ultrasound Indications


  • Relief of pain, muscle spasms and joint contractures that may be associated with:
    1. Adhesive capsulitis
    2. Bursitis with slight calcification
    3. Myositis
    4. Soft tissue injuries
    5. Shortened tendons due to past injuries and scar tissues
    6. Ligament sprains
  • Relief of sub-chronic, chronic pain and joint contractures resulting from:
    1. Capsular tightness
    2. Capsular scarring

Ultrasound Contradictions


  • This device should not be used over a healing fracture
  • Therapeutic ultrasound should not be applied over the pregnant or potentially pregnant uterus.
  • Areas of thrombophlebitis should not be treated with therapeutic ultrasound due to the increased possibility of clotting or dislodging a thrombus.
  • Tissues previously treated by deep x-ray or other radiation should not be exposed to therapeutic ultrasound.
  • Ultrasonic treatment over the stellate ganglion, the spinal cord after laminectomy, subcutaneous major nerves, and the cranium should be avoided.
  • This device should not be used over the gonads/testicles or to the developing fetus.
  • This device should not be used over the heart
  • This device should not be used on the brain.
  • This device should not be used on ischemic tissues in individuals with a vascular disease where the blood supply would be unable to follow the increase in metabolic demand and tissue necrosis might result.
  • This device should not be used over or applied to the eyes.
  • This device should not be used on the facial sinus as this exposes the eyes to the same hazards.


Performa Electrotherapy-Ultrasound unit Instructions

Warranty

3-Year Warranty

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close