DreamStation CPAP Machine Features
- Optional Heated Humidifier
- The Optional DreamStation Heated Humidifier is an add-on designed to prevent dryness and congestion as a result of sleep therapy. Integrate the machine and humidifier to provide warm air to CPAP users. A unique, Preheat feature has been incorporated into the DreamStation Humidifier to begin warming the water chamber 30 minutes in advance. Be sure the blower is turned to OFF and the humidifier is connected before selecting this feature
- Tube temperature and humidification settings can be set while the unit is in operation. Use the control dial to make the selections. Also, Adaptive mode can be enabled which will monitor ambient humidity levels and automatically adjust heat settings to provide optimum humidification while helping reduce rainout.
- Bluetooth Connection to DreamMapper App
- The DreamStation CPAP has a built-in Bluetooth connection which allows the device to pair directly with the PR DreamMapper mobile and web-based program. Enable the Bluetooth feature and download the SleepMapper app onto a smartphone or tablet (not included) to begin reviewing detailed sleep results. Use the free application to begin accessing nightly results through a personalized account on a handheld device
Please Note: The results are only available on one device at a time
- Ramp and SmartRamp
The Ramp feature and SmartRamp feature are both designed to gradually adjust the user to CPAP therapy. Though the Ramp features are similar, there are a few differences between the two options
- - Ramp is intended to gently increase CPAP pressure from half of the prescribed pressure to the full pressure within a chosen period of time. To operate the Ramp feature, a minimum CPAP pressure of 4cm H2O is required. Choose a time ranging from 5 minutes to 45 minutes to allow the machine to build the pressure in increments of 0.5cm H2O before reaching the prescribed pressure.
- In CPAP mode, SmartRamp uses an Auto-CPAP algorithm, making adjustments to the decreased pressure based on a breath by breath basis. Once SmartRamp reaches the prescribed pressure, the device will begin operating as a CPAP machine at the prescribed pressure
Please Note: During SmartRamp, if the minimum pressure is not reached before Ramp is complete, the pressure will increase by 1cm H2O each minute following the conclusion of Ramp
- C-Flex Technology
- C-Flex Technology is a pressure relief feature designed for CPAP machines. A range of settings numbered 1 through 3 are established to create varying levels of pressure reduction upon exhalation. Setting 1 is used to apply the least amount of change, while Setting 3 offers the greatest ease upon exhalation
- LCD On-Screen Display
- PRs DreamStation Series was built with a simplistic and practical LCD screen. While the User Interface is in use, the screen is well lit. As the lights in the room are dimmed, the screen;s sensor is designed expel the light from the screen
- Sleep results are posted on the User Interface to display results and goals for sleep therapy
- The first screen accounts for a "Three Night Summary" which is determined after 12pm on the third day of treatment
- Daily sleep compliance results are provided after the most recent session. If the user sleeps 4 or more hours, the session is considered successful, rendering a green bar on the right side of the screen. If the user does not reach the anticipated 4 hour mark, the therapy will be noted by a yellow bar in the right corner of the screen
- The second screen is in place for the first 90 days unless the sleep goal is met before the completion of this time. The data details the number of compliant nights recorded over the previous 30 days. A minimum of 21 successful four hour nights is needed to reach the 70% desired goal in order to surpass the screen before the end of 90 days
- Please Note: The control dial is used to view the menu. The screen does not have touch screen capabilities
- Respironics Dry Box Design
Dry Box technology was created to help reduce the chance of water damage when the OPTIONAL humidifier is used with the DreamStation machine. In the instance that water may escape from the chamber, the Dry Box is designed to trap the water within the walls of the unit to prevent water from traveling throughout the machine and humidifier connection. Additionally, the air outlet port uses a one way valve to prevent water from exiting the water chamber and entering the machine. The air outlet port is located on the top of the water chamber to help minimize total water displacement
- System One Resistance Control System
- One Resistance Control was developed by Respironics to help their machines reach the optimal pressure by using a numbering system which allows the CPAP device to recognize the mask. It achieves accuracy and reliability by instructing the device to compensate for the specific mask type.
Please Note:
- PR masks are the only masks designed with a resistance control number, so this machine feature is only compatible with Philips Respironics masks
- Rx Item Available by Prescription Only
- Prescription can be faxed to 1.203.616.2851 or emailed to [email protected]
What To Buy With Dreamstation Cpap?
How To Use Philips Dreamstation Cpap?
Ramp: Choose the time in which the machine will gradually adjust the user to the prescribed pressure
Flex: Select between 3 flex settings intended to decrease the pressure upon exhalation
Humidification: Determine the humidity level by selecting a number from 0 to 5. Level 0 represents humidification that has been turned OFF, while Level 1 is the lowest form of humidity and Level 5 is the most significant level of humidity. Also, the DreamStation Humidifier can deliver different humidification modes: Fixed Humidification, Adaptive Humidification, and Heated Tube Humidification
Tube Type: Specify the type of CPAP hose being used with the machine. The setting will correspond directly to the diameter of the hose, whether it is 22mm or 15mm. A separate setting can be selected by those using a 15H Heated Tube
Modem: Use the screen to control the modem. If the modem is switched to OFF, it will automatically turn ON again after 3 days
Bluetooth: Enable the bluetooth option to transmit sleep data from the machine to a personalized DreamMapper account
Time: Use this option to change or update the display time in increments of 30 minutes from this screen. The default setting is Greenwich Mean Time
Important Tips while using Dreamstation Cpap
Connect to Bluetooth Wireless Technology
DreamMapper is a mobile and web-based system designed to pair with the DreamStation CPAP and BiPAP machines. Download the SleepMapper app onto a smartphone or tablet (not included) to access daily results. Please Note: The wireless technology cannot connect to multiple mobile devices during the same period of time. The technology is most proficient when the machine and mobile device make the connection in the same room. Before pairing the devices, be sure the Bluetooth setting has been enabled and the machine is powered OFF
Pacemaker Safety Tips
- Per the manufacturer, the Health Industry Manufacturers Association recommends a 6 inch distance between a pacemaker and a wireless device. Due to the bluetooth wireless technology which has been built into the machine, it is highly suggested that those with a pacemaker maintain a minimum distance of 6 inches from their machine
Humidification Tips
The DreamStation CPAP is only compatible with the DreamStation Heated Humidifier. Select one of the two modes
- Fixed Humidification: Select a number within the range of 0 to 5 to choose the humidity level. Level 0 represents a humidifier that has been turned OFF. Level 1 disperses the least amount of humidity, while Level 5 disperses the greatest amount of humidity. In Fixed mode, the humidifier will produce one level of humidity throughout therapy
- Adaptive Humidification: In Adaptive mode, the humidifier will monitor the environment to produce the lowest level of humidity needed to prevent condensation in the hose. Adaptive humidification can adjust as the temperature in the room changes
Please Note: When a heated tube is added to therapy, the humidifier will automatically change to Heated Tube Humidification Mode. The temperature of the heated plate and heated hose can be changed, but the mode will remain locked in Heated Tube Humidification Mode while the hose is attached. Just as fixed humidification ranges from 0-5, the temperature of the heated tube can be adjusted by choosing a level from 0 to 5
Compatible AC and DC Power Used to Operate the DreamStation
A power cord and the DreamStation 80 Watt Power Supply are included with the purchase of the DreamStation CPAP machine. Attach the power cord and the power supply before placing the 2 prong plug into the outlet. Turn the machine with the knob facing forward so the power cord connector snaps into the power inlet found on the left-hand side near the back of the machine. Caution: Avoid using an extension cord to operate the CPAP. Use the Shielded DC Cord to operate DreamStation devices from a resting vehicle battery. A 12 V DC battery is needed when the DC power cord is paired with a DC battery adapter cable.
Caution: Only operate a DreamStation machine from DC power once the vehicle engine has been turned OFF.
How To CLean CPAP Machines?
- Before cleaning, unplug the DreamStation device from the power cord. Do not submerge the machine in water or cleaning products. Instead, use mild soap and a slightly damp washcloth to clean the machine. Re-connect power once the device is completely dry
- The non-heated 22mm or 15mm CPAP hoses may be submerged in water and mild detergent to clear away residue. Rinse the hose entirely and allow it to air dry away from sunlight. If cleaning a heated hose, use a hose brush or damp cloth to clean the tube. The hose cannot be submerged in water
Tips for Cleaning the Filters
- For optimal results, clean the reusable filters at least once every two weeks. The reusable filter is intended to last 6 months when cared for properly. When using the ultra-fine filter in conjunction with the reusable filter, replace the ultra-fine filter after 30 days of use or after it becomes dirty. Do not wash the ultra-fine filter
- First, remove the ultra-fine filter if it is being used to capture very small particles
- Next, pull the reusable filter from the machine to run it under warm water
- Gently shake the filter to excrete all excess water. Let the filter air dry completely away from direct sunlight
- Once the filter is completely dry, restore the filters to their place on the machine
Tips for Installing or Replacing Filters
With the machine knob facing forward, locate the compartment on the righthand side of the machine. Lift the lid to access the filter assembly. If the OPTIONAL ultra-fine filter is dirty or if it has been in place for 30 days, dispose of the filter. Clean the reusable filter and place it atop the OPTIONAL disposable filter before affixing the filters together. Complete the progress by moving the filter assembly back into its previous placement. The compartment door will close to ensure the filters are safely stored.
Please Note: The reusable filter is required to operate the DreamStation CPAP machine
Dreamstation Portable CPAP Machine Specifications
Particulars |
Specifications |
Modes |
Fixed CPAP |
Features |
N/A |
Pressure Range |
4 to 20 cm H2O |
Flex Comfort |
C-Flex |
Humidification Modes (3) |
Fixed Adaptive Heated Tube |
Mask Type Resistance Control |
Standard |
Ramp (5-45 minutes) |
Standard SmartRamp |
Altitude Compensation |
Automatic |
Advanced EventDetection |
N/A |
Flow Waveforms |
N/A |
Modem Compatibility |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Built-in Bluetooth Connectivity |
Standard |
DreamMapper Compatibility |
Standard (by mobileapp or web) |
Oximetry Compatibility |
Standard (optional Nonin accessories) |
Check Mask Fit feature |
N/A |
Performance Check |
Standard |
Dimensions - Machine Alone |
6.2 in L x 7.6 in W x 3.3 in H
(15.7 cm L x 19.3 cm W x 8.4 cm H) |
Dimensions - Machine and OPTIONAL Humidifier (Excluding Air Outlet Port) |
11.7 in L x 7.6 in W x 3.3 in H
( 29.7 cm L x 19.3 cm W x 8.4 cm H) |
Weight - Machine Alone |
1.56 lbs (0.71 kg) |
Weight - Machine and Power Supply |
2.94 lbs (1.33 kg) |
Weight - Machine and OPTIONAL Humidifier with Power Supply |
4.37 lbs (1.98 kg) |
Weight - OPTIONAL Humidifier Alone: |
1.44 lbs (0.65kg) |
Operating Temperature |
41 degree F to 95 degree F (5 degree C to 35 degree C) |
Storage Temperature |
-4 degree F to 140 degree F (-20 degree C to 60 degree C) |
Relative Humidity (Operating & Storage): |
15 to 95% (non-condensing) |
Atmospheric Pressure |
0 - 7500 ft (0 - 2286 m) (101 to 77 kPA) |
AC Power Consumption (with 80W Power Supply) |
100 - 240 VAC, 50/60 Hz, 2.0 - 1.0 A |
DC Power Consumption |
12 VDC, 6.67 A |
Material Components - Pollen Filter |
100% Polyester, 88% Efficient at 7 - 10 micron size |
Material Components - Ultra-Fine Filter |
Blended Synthetic Fiber, 95% Efficient at 0.5 - 0.7 micron size |
Compatible CPAP Tube Diameter |
22mm Standard, 15mm Slim, 15H Heated Tube |
Operating Frequency Range |
2402 - 2480 MHz |
Maximum Output Power |
4.0 dBm |
Sound Pressure Level (DreamStation CPAP) |
25.8 dB(A) with an uncertainty of 2 db(A) |
Sound Pressure Level
(DreamStation CPAP and Humidifier) |
27.9 dB(A) with an uncertainty of 2 db(A) |
Sound Power Level (DreamStation CPAP) |
33.8 dB(A) with an uncertainty of 2 db(A) |
Sound Power Level
(DreamStation CPAP and Humidifier) |
35.9 dB(A) with an uncertainty of 2 db(A) |
Portable CPAP Warranty
2 years warranty, an extended 3 years warranty option is available for purchase to give your patients additional peace of mind.