Drive SportNeb 2 Compressor Nebulizer is designed to efficiently deliver the prescribed saline solution to treat respiratory disorders, such as asthma, allergies, and bronchitis. The SportNeb2 converts the saline solution into an aerosol mist that penetrates through lungs. It provides a quick, effective dosage allowing to get back to the daily activities by generating a particle size of less than five micrometers. The powerful piston pump is efficient, dependable and quiet.

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

Item #DescPkgPrice 
3050-2 4.1"H x 5.7"W x 7.9"D Each $68.85 $41.99

Features

  • Drive SportNeb 2 Compressor Nebulizer includes two filters
  • Comes with disposable nebulizer kit that includes:
    - Medication cup
    - T-adapter
    - 7 Feet tubing
    - Mouthpiece
    - Reservoir tube
  • Employs a compact, lightweight design with a built-in carry handle maximizing portability
  • Compact design includes a convenient carry handle
  • Built-in cord storage
  • Weight : 3.5lb
  • Also available (Separately):
    - Drive Disposable Nebulizer Kit (Code : NEBKIT500)

More Information

  • Operation Instructions
    - Place compressor on a stable, sturdy and flat surface such that the unit can be easily reached when youre seated
    - Pull out the power cord from the base of the unit, and make sure that the unit is in the off (0) position by pressing on the left side of switch
    - Plug power cord into a 120VAC/60Hz wall outlet
    - Connect one end of the nebulizer tubing into the air outlet connector
    - Add the prescribed saline solution through the opening on cap using an eye dropper or per-measured dose container
    - Assemble mouthpiece and T-piece, and insert into the top of the nebulizer cap. If an aerosol mask applied connect the bottom of mask to the top of nebulizer cap
    - Connect tubing to nebulizer air inlet connector
    - Turn the power on to start the unit
    - Implement the treatment by placing the mouthpiece between the teeth. Inhale and exhale through the mouthpiece
    - If aerosol applied place the mask over the mouth and nose
  • Cleaning
    - Turn the power off and unplug from the wall outlet
    - Remove the tubing from the air inlet
    - Disassemble mouthpiece, T-piece, nebulizer cap, chamber and baffle, and wash these items except the tubing in hot water with dish-washing detergent. Rinse these items thoroughly to remove the detergent
    - Mix one part of white vinegar with 3 part of hot distilled water, and use a clean container to carry this disinfectant solution. Submerging mouthpiece, T-piece, nebulizer cap, chamber and baffle for half an hour
    - Remove these cleaned units from container and let them dry in the air
    - There is no need to clean the tubing if necessary wipe the surface of it regularly
  • Maintenance
    - The filter of air compressor should be replaced when it turns gray. The additional filter can be procured from your dealer
    - Authorized personnel maintain the rest of this machine only
  • Danger: To reduce the risk of electrocution
    - Always unplug the unit immediately after using
    - Do not use while bathing
    - Do not place or store the unit where it can fall or be pulled into a tub or sink
    - Do not place or drop into water or other liquid
    - Do not reach for a product that has fallen into water. Unplug immediately
  • Warning: To reduce the risk of burns, electrocution, fire or injury
    - Electrical Shock Hazard - do not remove the cabinet or open the cover
    - Disconnect the power cord from the electrical outlet before cleaning or servicing
    - Do not place this equipment near hot, sparking or burning objects
  • To reduce the risk of burns, electrocution, fire or injury
    - Do not use oil or grease on or near this device
    - Turn the unit off when it is not in use
    - Keep the cord away from HEATED or HOT surfaces
    - NEVER drop or insert any object into any opening
    - NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked
    - Avoid the operation in wet or damp locations
    - Unplug the unit before filling the nebulizer
  • To reduce the risk of infection
    - The Nebulizer kit with a mark on it should not be reused
    - To prevent the risk of cross infection, different persons should never use the same nebulizer kit
    - If you are using a reusable nebulizer kit, cleaning of the nebulizer is recommended after each aerosol treatment. Disinfecting is recommended once a day
    - Use only the FDA or CE approved nebulizer kits

Specification

ParticularsSpecifications
Electrical Requirements120VAC/60Hz
Power Consumption110W Max
Max. Comp. Pressure30 Psig or greater
Neb. Operating Pressure10 Psig or greater
Sound Pressure Level58dB(A)
Compressor Free Air Flow8lpm or greater
Particle SizeLess Than 5 microns
Operating Temperature10°C ~ 40°C (50°F to 104°F)
Operating HumidityUp to 95% non-condensing
Storage/Transport Temperature Range-20°C ~ 60°C (-4°F to 140°F)
Storage/Transport HumidityUp to 95% non-condensing
Method of NebulizationPiston Compressor
Particle Size0.5 µm to 5 µm
Unit Dimensions5.7" (W) x 4.1" (H) x 7.9" (D)

Warranty

5 year limited warranty

Customer Reviews

Questions & Answers


 
 
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close