Mic-Key 16FR Low-Profile Gastrostomy Feeding Tube Kit

Authorized Retailer BadgeAuthorized Retailer
Product Option

Stoma Length, 0.8cm

SKU 0120-16-0.8
$144.89 Each

Stoma Length, 1.0cm

SKU 0120-16-1.0
$144.89 Each

Stoma Length, 1.2cm

SKU 0120-16-1.2
$153.06 Each

Stoma Length, 1.7cm

SKU 0120-16-1.7
$144.69 Each

Stoma Length, 2.0cm

SKU 0120-16-2.0
$145.91 Each

Stoma Length, 2.3cm

SKU 0120-16-2.3
$143.36 Each

Stoma Length, 2.7cm

SKU 0120-16-2.7
$153.06 Each

Stoma Length, 3.0cm

SKU 0120-16-3.0
$153.06 Each

Stoma Length, 3.5cm

SKU 0120-16-3.5
$153.06 Each

Stoma Length, 5.0cm

SKU 0120-16-5.0
$153.06 Each
Request quote

MIC-KEY Low-Profile Gastrostomy Feeding Tube 16FR Kit is designed for enteral feeding, providing a way to deliver nutrition directly to the stomach. The term "low-profile" indicates that the tube is designed to sit relatively flat against the skin, reducing the risk of snagging or catching on clothing. This MIC-KEY Gastrostomy Tube is a step up from conventional G tubes. Highly popular and widely prescribed, the Mic-Key is unobtrusive and easy to conceal, making it an ideal feeding tube for virtually all individuals.

What does the MIC-KEY Gastrostomy Feeding Tube Kit Include?

  • MIC-KEY Low-Profile Gastrostomy Feeding Tube
  • Insertion Stylet (US Only)
  • Water-soluble Lubricant (US Only)
  • Continuous Feed Extension Set, 12-inch
  • Bolus Feed Extension Set, 12-inch
  • 6ml Luer Slip Syringe
  • 35ml Enteral Feeding Syringe
  • Gauze Pad

Autoship

$124.89 $191.65

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $7.24 in HPFY rewards

One-time purchase

$144.89 $191.65

Earn $7.24 in HPFY rewards

MIC-KEY Low-Profile Gastrostomy Feeding Tube Kit 16FR Features

  • Radiopaque stripe 
  • Single-Use
  • Mic-Key Gastrostomy Feeding Tube is latex-free and sterile
  • Less cumbersome than conventional gastrostomy tubes for active patients
  • High clarity medical grade silicone construction, designed for visibility and drapability
  • The low-profile design makes it unobtrusive and easier to conceal 
  • Tapered distal tip recessed at a recommended fill volume
  • Ventilated secur-lok ring, the external retention mechanism designed to allow air to circulate around the stoma site and reduce tube pressure 360º from the sides of the stoma wall 

Product Benefits

  • Designed for visibility and drapability
  • Patented universal connector
  • Designed to preserve tube life
  • Minimize unintentional disconnects
  • Inflatable internal retention balloon
  • Proximal anti-reflux valve

Frequently Bought Together

 

How to use Mic-Key Gastrostomy Feeding Tube 16Fr Kit?

  1. Attach - To start, attach the MIC-KEY G Extension Set to the MIC-KEY G feeding port by matching the black lines on the extension set and feeding port. Push the extension set down firmly and “lock” it into place by turning the connector CLOCKWISE until you feel a slight resistance (approximately three-quarters turn).
    Note - Do not turn the connector past the stop point. It is important to keep the extension set “locked” into place during feeding.
MIC Key G Enteral Feeding Tube
 
  1. Flush - Next, flush your MIC-KEY Low-Profile Gastrostomy Feeding Tube Kit 16FR with water. Use either extension set to flush.
  2. Begin - Now begin enteral feeding.
    • For bolus feeding - Attach a bolus syringe filled with your preferred nutrition
    • For continuous feeding- Attach a feeding set to a feeding pump with your preferred nutrition in the bag

How to Remove Extension Set From MIC Tube?

  • Disconnect the extension set from the MIC-KEY G feeding tube port by rotating it COUNTER-CLOCKWISE until the black line on the feeding port lines up with the black line on the extension set
  • Gently detach the extension set and cap the MIC-KEY G Feeding Tube securely with the attached feeding port tube cover
    Cautions -
    • It is recommended to connect only the MIC-KEY Extension Set to the MIC-KEY G Feeding Tube.
    • To avoid damage, do not insert medication or nutrition directly into the feeding port valve without the use of an extension set.
    • Flush the tube and extension sets before and after every use to prevent clogging.
MIC Key Gastrostomy Tube
 

How to care for a MIC KEY Gastrostomy Tube?

Cleaning And Caring of MIC-KEY G-Tube for Stoma Site -

  • Wash hands thoroughly with warm, soapy water before touching the tube
  • Clean the skin around and under the MIC-KEY G feeding tube daily using mild soap, water, and a soft, lint-free cloth or cotton-tipped applicator
    Note - Avoid puncturing or tearing any part of the tube or extension sets

MIC-KEY G Tube & Port Care -

  • Clean the external portion of the tube
  • Be careful not to pull or manipulate the tube excessively
  • Make sure both your tube and stoma are kept clean and dry

Tips for using MIC-KEY 16FR Low-profile G-tube

  • To avoid a “balloon burst,” use your MIC-KEY G Feeding Tube, as indicated in the Instructions for Use (IFU)
  • To avoid damage, always use the correct equipment. Only use the extension sets as instructed by a clinician. Only use a syringe for its intended purpose.
  • Replace extension sets as per the IFU.
  • Only use sterile or distilled water to fill your balloon.
  • A medical professional will determine the proper length of the tube by using a stoma-measuring device and then recommend the proper length. If there are issues with the tube or stoma or significant weight is gained or lost, contact your care team. A new measurement could be required.
  • The external base of the tube should rest just above the skin surface. A good fit is considered 1 to 2 mm above the skin, about the thickness of a dime. If the external base is sitting too low or high, contact your clinician to see if you need to be re-measured.
  • Refer to the IFU or the first page of this guide for the inflation volumes of your balloon. It will vary based on tube size.
  • Only use water-soluble lubricant.
  • The MIC-KEY G Feeding Tube features an anti-reflux valve located toward the top of the feeding port. When you attach the extension set, this valve is opened to allow feeding. It is important to keep both the feeding port and the anti-reflux valve clean with proper flushings.
  • To avoid valve damage, do not insert medication or nutrition directly into the feeding port valve.


Contraindications - Contraindications for placement of a tube include, but are not limited to, ascites, colonic interposition, portal hypertension, peritonitis, and morbid obesity.

User Manual

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

MIC-KEY Low-Profile Gastrostomy Feeding Tube Kit 16FR Reviews

More Kimberly Clark Feeding Tube Extension Sets

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close