Features
- Drive Beagle Pediatric Compressor Nebulizer comes with:
-Â Disposable neb kit
- Mouthpiece
- Pediatric aerosol mask
- Replacement filter
- Instructions
- Reusable and disposable nebulizer kit contents:
-7 feet tubing
- T adaptor
- Nebulizer or medication cup
- Reservoir tube
- Mouthpiece
- Fun and entertaining doggy stickers included
- Convenient Doggy House Backpack case comes inside each Beagle Neb box
- Note:
- This product requires a prescription from a licensed medical professional.
- Prescription can be faxed to 1.203.616.2851 or emailed to [email protected].
- Also available (sold separately) :
-Â Drive Reusable Nebulizer Kit (Code : 18254)
-Â Drive Disposable Nebulizer Kit (Code : NEBKIT500)
Beagle Pediatric Nebulizer Guides
Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here
More Information
- To reduce the risk of electrocution
- Always unplug this product immediately after using
- Do not use while bathing
- Do not place or store product where it can fall or be pulled into a tub or sink
- Do not place in or drop into water or other liquid
- Do not reach for a product that has fallen into water. Unplug immediately
- To reduce the risk of burns, electrocution, fire or injury to persons
- The product should never be left unattended when plugged in
- Close supervision is necessary when this product is used by, on, or near children or disabled individuals
- Use this product only for its intended use as described in this guide. Do not use attachments not recommended by the manufacturerNever operate this product if
- It has a damaged power cord or plug
- It is not working properly
- It has been dropped or damaged
- It has been dropped into water
- Keep the power cord away from heated surfaces
- Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and the like
- Never use while drowsy or asleep
- Never drop or insert any object into any opening or hose
- Do not use outdoors. This product is for household use only
- Do not use in an oxygen enriched environment
- Do not use this product with a DC to AC converter, or with any AC voltage and/or frequency other than specified
- Do not operate unit in a backpack or carrying bag
- Care should be taken when this product is used in the vicinity of other electronic equipment concerning the possible interference between them. They may need to be moved apart
- Use caution when plugging in and unplugging device. Do not allow jewelry or other metal items to contact plug
- Warning: This product contains small parts that may represent a choking hazard
- Not intended for use with OXYGEN or OXYGEN ENRICHED ATMOSPHERES
- What are Compressor Nebulizer Systems Used For?
- People with breathing problems, such as Asthma, Chronic Obstructive Pulmonary Disease (COPD) or Cystic Fibrosis are often prescribed medicines that minimize or control symptoms of their disease
- Compressor Nebulizer Systems are a means of delivering these prescribed medications to the lungs
- These medications and the compressor nebulizer systems should be used as directed by a physician to maximize benefits
- Compressor Nebulizer systems can be prescribed for use everyday or periodically as symptoms present themselves, such as the springtime when Hay Fever or Allergies are normally present
- Daily Use Operation
- Before each use inspect the Compressor and nebulizer cup assembly for damage or wear, replace as needed
- Place the Compressor on a table or other flat stable surface. Be sure the user can easily reach the controls when seated. Do not use this device on the floor
- With the power switch in the O (OFF) position, plug the power cord into an appropriate electrical wall outlet
- Connect one end of the tubing to the compressor air-outlet connector
- Assemble the nebulizer cup and add indicated medication to the nebulizers cup before use
- Attach the other end of the tubing into the air-inlet connector found at the bottom of the nebulizer cup
- Turn on the Compressor by pressing the power switch to the I (ON) position and begin treatment
- If treatment needs to be interrupted, simply press power switch to O (OFF) position
- When the treatment is complete, turn off the compressor by pressing the power switch to O (OFF) position and unplug the unit from the electrical outlet
- Always unplug this device immediately after use
- Not intended for use with OXYGEN or OXYGEN ENRICHED ATMOSPHERES
- Safety Instructions
- NOTE Do not exceed 30 minutes of continuous operation
- The motor of this device has a built-in thermal overload protector. Should the motor overheat, the protector will automatically shut off the motor. Should this occur, turn the I/O (ON/OFF) switch to the O (OFF) position and allow the motor to cool down for approximately 30 minutes before turn it on again
- If the overload protector shuts off the motor frequently, the user may have an unstable voltage situation
- Nebulizer Cleaning
Clean After Every Use
- With power switch in the Off position, unplug power cord from wall outlet
- Disconnect tubing from the air-inlet connector and set aside
- Disassemble mouthpiece or mask from cup. Open nebulizer by turning cap counterclockwise and remove baffle
- Wash all items, except tubing, in a hot water/dishwashing detergent solution. Rinse under hot tap water for 30 seconds to remove detergent residue. Allow to air dry
- For reusable nebulizer kit only, it can be cleaned daily in dishwasher using top shelf or by following the above cleaning procedure
- Disinfect Daily
- Using a clean container or bowl, soak items in three parts hot water to one part white vinegar for 30 minutes OR use a medical bacterial-germicidal disinfectant available through the provider. Be sure to follow manufacturers instructions carefully
- With clean hands, remove items from disinfectant solution, rinse under hot tap water, and air dry on a clean paper towel. Store in a zip-lock bag
- Compressor Cleaning
- With power switch in the Off position, unplug power cord from wall outlet
- Wipe outside of the compressor cabinet with a clean damp cloth every few days to keep dust-free
- Maintenance
- All maintenance must be performed by a qualified Drive provider or authorized service center
Specification
Particulars |
Specifications |
Method of Nebulization |
Piston Compressor |
Particle Size |
0.5™µm |
Unit Dimensions |
8.56 W x 5.63 H x 8.56 L |
Weight |
3.1lb |
Maximum Pressure |
42 PSI |
Operating Pressure |
13 PSI |
Liter Flow |
8 lpm |
Power |
AC 120V 60Hz |
Power Consumption |
180 VA Max |
Medication Capacity |
5 ml |
MMAD |
4um |
Sound Level |
Less than 60 dB at 3.3ft |
Average Nebulization Rate |
= 0.2ml/min |
Compressor Pressure Range |
25 to 42 PSI |
Operating Pressure Range |
8 to 13.05 PSI |
Air Flow Range |
5 ~ 8 lpm |
Operating Temperature Range |
50O to 104O F |
Operating Humidity Range |
10 to 95% RH |
Storage Temperature Range |
-13O to 140O F |
Storage Temperature Humidity |
10 to 95% RH |
Dimension |
8.56"L x 8.56"W x 5.63"H |
Weight |
3.1lb |
Warranty
5 year limited warranty on compressor parts, Your Drive brand product is warranted to be free of defects in materials and workmanship for five years of the original consumer purchaser. , This device was built to exacting standards and carefully inspected prior to shipment. This 5 year Limited Warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable service. ,This warranty does not cover device failure due to owner misuse or negligence, or normal wear and tear. The warranty does not extend to non-durable components which are subject to normal wear and need periodic replacement. If you have a question about your Drive device or this warranty, please contact an authorized Drive dealer.
Related Articles
{{x.ShortDescription}} ...
Share