Uresil Tru-Close Suction Drainage System - 500mL Capacity

This product is on backorder and will be available to purchase once it is back in stock.

Options

Item# Description Pkg reward$ Price Blank
Item #: TCS500D
With Empty Port
10/Pack
10/Pack
reward$
$28.65
$745.05
$573.09

Uresil TRU-CLOSE Suction Drainage System is intended to be a completely closed system for the drainage of abscesses and other fluids. The system's compact and self-contained design allows for full patient ambulation. Body fluids are not aerosolized during activation. A closed system design reduces the possibility of cross-contamination. Dual reflux valves keep liquids and air from backing up into the wound drain or catheter.

Tru-Close Drainage Suction System Features

  • Latex-free
  • Dual anti-reflux valves
  • With or without empty port
  • Reduces the chance of cross-contamination

Why choose Tru-close drainage system?

  • Dual anti-reflux valves prevent liquids and air from backing up into the catheter or wound drain. 
  • All TCS bags come with a standard Luer lock connector to fit all luer-locking drainage catheters
  • TCS500DS comes with two straight connectors to be used with post-surgical wound drains. 
  • If the bellows fills, flow to the bag continues via gravity drainage as long as the bag is below the level of the drainage site.
  • Available with empty port
  • Approx. Vacuum:
    • TCS500: 2 PSI(103 mm Hg)
    • TCS500D: 2 PSI(103 mm Hg)
    • TCS500DS: 4.5 PSI(233 mm Hg)

Uresil drain bags Intended Use:

  • For collecting drainage fluids this product is intended for short-term use (more than 24 hours and less than 30 days).


Uresil Tru-Close Suction - 500mL Capacity Instruction Manual

What to buy with Uresil Closed Drainage System

How To Use Tru close Drainage Bag?

  • To adjust the tubing length, remove the tube from the top of the housing or pull off the luer lock connector and cut the tube with a scissors to the desired length.
  • To change the luer lock connector to a straight connector for use with a silicone wound drain, cut the tube or remove the adapter and insert the desired connector.
  • Attach the bag to the drainage catheter or wound drain. 
  • To ensure continuous flow, attach the bag to the patient gown or bedding below the level of the drainage site. 
  • If the bag comes with an empty port, twist it closed.
  • To activate the system, compress the bellows completely. Do not try to pump the bellows; it will fill as it draws fluid from the drainage site. If the bellows is not re -activated after filling, the system will convert to gravity drainage thus preventing fluid backup. 
  • To re -activate the system, compress the bellows. The fluid in the bellows will be discharged into the bag and the suction will be re -established. 
  • The bag is strong enough to withstand a build up of air pressure within the bag. The bag is equipped with hydrophobic filter vents, which will vent collected air. Air can be manually forced out of the bag by gently squeezing the bag while the system is positioned vertically (housing above bag). 
  • Although the graduation marks on the bag are approximations only, approximate volumes collected can be recorded on the white “write -on” area on the bag. When recording these approximations, first empty bellows contents into the bag.

How to empty the drain?

Empty the drain when it is half full or every 4 to 8 hours:

  • Wash your hands with soap and water.
  • Empty the fluid in the bellows into the bag.
  • Unscrew the port on the bottom of the bag over a measuring cup.
  • Let the fluid drain into the cup.
  • Clean the port with an alcohol swab or a cotton ball dipped in rubbing alcohol.
  • Squeeze the bellows flat and screw the port closed.
  • Make sure the tubing is not kinked or twisted. Refasten to your clothes below your surgery site so it does not pull at your skin.
  • Measure the amount of fluid you pour out. Write down how much fluid you empty from the drain and the date and time you collected it. Bring this record with you to your follow-up visits.
  • Flush the fluid down the toilet. Wash your hands.

Warnings/Precautions:

  • Discard the entire system when the bag is full or when otherwise indicated. 
  • Sterile if the package is unopened and undamaged. 
  • For single use only. 
  • The reuse of this single-use device can lead to patient infection and/or device malfunction. 
  • Bags without empty ports only: Do not attempt to empty the bag during the use. The bag can be emptied prior to disposal if desired by cutting off the bottom corner of the bag.

Technical Specifications

Catalog Number Bag Size Approx. Vacuum Drain Port? Luer Lock Fitting? Friction Fittings?
TCS500DS 500 ml 4.5 PSI (233 mm Hg) Yes Yes Yes
TCS500D 500 ml 2 PSI (103 mm Hg) Yes Yes No
TCS500 500 ml 2 PSI (103 mm Hg) No Yes No

Customer Reviews

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close