Get 15% Off $50*, Code: HP15

Day
:
:
Online since 2002 |   866-316-0162

View product option

Responsive Respiratory Respond C5 Single Lumen Conserver With M6 Case

Responsive Respiratory Respond C5 Single Lumen Conserver With M6 Case is a high-pressure oxygen regulator and conserving device that is combined into a single compact unit. It operates in the same manner as traditional oxygen pressure regulators with the added benefit of having a conserving device included. The system is designed for use by an ambulatory patient with a high-pressure oxygen cylinder. Since the Respond C5 requires no electrical (battery) power source, it is a reliable and easy to use the device.

Features

  • Responsive Respiratory Respond C5 Single Lumen Conserver With M6 Case is a combined regulator and conserving device
  • It provides therapy and conserves oxygen by delivering the patient;s prescribed liter flow only during inhalation
  • The user can switch between Continuous and Conserve
  • Mode simply by turning the knob
  • The device has a compact one-piece aluminum body with all-brass in the high-pressure zone
  • It includes a click-style flow control with 10 flow settings
  • For additional safety and longer device life, it has a sintered bronze high-pressure inlet filter
  • Whisper quiet - ideal for church, movie bingo outings
  • 2-in-1 design with built in regulator
  • 5:1 Conservation {1, 2, 2.5, 3, 4, 5}
  • Continuous Flow 2, 3, 4 LPM
  • Includes M6 Cylinder Carry Case
  • User Manual

More Information

  • Removal of the Respond C5 from the cylinder:
    - Close the cylinder valve
    - Set the adjusting knob to the lowest flow setting and allow the regulator to de-pressurize
    - Be sure the contents gauge reads zero
    - Remove regulator from cylinder valve
  • Cleaning and Maintenance:
    - The exterior surfaces can safely be wiped off with a clean, lint-free cloth.
    - If the cloth is dampened with water, do not let water enter the relief valve or vent holes
  • Warning:
    - If grease or oil is visible or suspected to be present, DONOT use the device, and do not attempt to clean or repair it
    - Have it serviced by qualified personnel
    - If any leakage of the oxygen cylinder is detected, turn the valve stem or handle clockwise until the cylinder valve is closed
    - If leakage persists, place the cylinder outdoors and notify the gas supplier immediately

Warranty

Three Years Warranty

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close