Philips Fetal Spiral Electrode
Philips Fetal Spiral Electrode

Philips Fetal Spiral Electrode

Brand/Manufacturer: PHILIPS MEDICAL SYSTEMS
Save

Philips Fetal Spiral Electrode is for use on patients requiring fetal heart rate monitoring by way of fetal scalp during labor and delivery and meets the highest standard of safety and protection. A new handle features a protection tab that keeps the spiral tip inside the tube during insertion. As a result, there is an unlikely chance of it accidentally harming the mothers birth channel, the fetus, or your inger tips.

Item #DescPkgRewardPrice 
9.90E+11 Electrode 25/Case $4.53
$263.75
$226.54

Features

  • Philips Fetal Spiral Electrode is latex free and DEHP free
  • Protection tab serves as a visual reference point to indicate how far the spiral has turned when attaching the electrode

More Information

  • Contraindications:
    - Do not apply to fetal face, fontanels, or genitalia, or when placenta previa is present or suspected, or in the presence of active herpes lesions, hepatitis C or HIV infection.
    - Do not apply when woman is a confirmed carrier of hemophilia and fetus is affected or status is unknown, or when it is not possible to identify fetal presenting part where application is being considered.
  • Warnings:
    -
    Due to design of the FSE, penetration of fetal epidermis may possibly cause trauma, hemorrhage and/or infection. Thus, the FSE must be used under conditions of aseptic technique.
    - Amniotic membranes must be ruptured prior to attachment of the FSE.
    - This FSE is intended for fetal monitoring only. Any other use may damage the device and result in difficulty attaching it to a fetus, or adversely affect its ability to aquire and maintain an accurate fetal signal.
    - Remove the FSE from patient before performing any electro-surgical procedures.
    - Do not pull the Spiral Tip from the fetal skin. Do not pull the FSE wires apart.
    - Do not over-rotate Spiral Tip during attachment.
    - Reuse may cause degradation of physical or electrical properties.
    - Do not reuse on another patient due to risk of cross-infection.

Customer Reviews

Questions & Answers


 
 

Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image
what cables can they be used with
M Meyer - 4/22/2015 6:40:26 PM
facebooktwitter
answer image
Thank you for reaching out to us. Philips Fetal Spiral Electrode can be used with: PHILIPS - 989803137791 DECG REUSABLE LEGPLATE ADAPTER PHILIPS CABLE (Round Connector)
PHILIPS - 989803137801 DECG REUSABLE LEGPLATE ADAPTER PHILIPS CABLE (Rectangle Connector)
PHILIPS - 989803137811 DECG REUSABLE LEGPLATE ADAPTER PHILIPS CABLE
Customer Care - 4/24/2015 3:51:28 AM
question image
Can these be sterilized and reused or are they single use?
Erin - 10/12/2014 11:57:58 PM
facebooktwitter
answer image
Thanks for contacting us. This product is for single use only because reuse may cause degradation of physical or electrical properties.
Customer Care - 10/16/2014 1:58:59 AM