Mettler Sys Stim 240 Light Therapy Applicator Kit
Mettler Sys Stim 240 Light Therapy Applicator Kit

Mettler Sys Stim 240 Light Therapy Applicator Kit

Brand/Manufacturer: METTLER ELECTRONICS
Save

Mettler Sys Stim 240 Light Therapy Applicator Kit provides therapeutic infrared light for temporary increase in blood circulation, temporary relief of minor muscle and joint aches, pains and stiffness, temporary relaxation of muscles and temporary relief of minor pain and stiffness associated with arthritis. It is to be used with Mettler Sys Stim 240 Neuromuscular Stimulator.

Item #DescPkgRewardPrice 
2407 Light Therapy Applicator Kit Each $85.80
$6189.75
$4289.75

Features

  • Mettler Sys Stim 240 Light Therapy Applicator Kit includes:
    - Laser applicator (785/470nm, 80mW)
    - Cluster applicator (950/550nm, 500mW)
    - Right and left applicator holders with mounting hardware
    - One pair of protective glasses
  • Plug and play light therapy
  • Control intensity or repeat treatments from the applicator 500mW cluster and/or 80mW laser
  • Treatment protocols available
  • Memory for user-defined protocols
  • Also available:
    - Mettler Sys Stim 240 Neuromuscular Stimulator (Code 567696)

Specification

ParticularsDimensions
Output PowerDependent on Applicator (automatically sensed)

Laser diode applicator

80mW at 785nm
Cluster applicator500mW at 660/950nm

Delivered energy

0.01 to 99.99 Joules
Operation modesContinuous and Pulsed
Pulse mode
Laser100us nominal
Cluster50% duty cycle
Pulse frequencyContinuous
10Hz, 25Hz, 50Hz, 100Hz, 250Hz, 500Hz, 1kHz, 2.5kHz, 5kHz (Pulses per Second)
Sweep from 10 to 5kHz in 10 seconds
Timer0 to 99 minutes 59 seconds, 1 second increments (decrementing). Audible signal and output termination at time expiration


Laser Applicator
ParticularDimensions
Lasing deviceSanyo Single AlGaAs Diode (Class 3B laser device)
Wavelength785nm ± 10nm
Power80mW ± 10mW
Treatment area illuminationThree Blue LED;s (470nm, visible through eyewear protection that attenuates infrared/near infrared)
Output activationCapacitance switch on Laser Applicator handle
NOHDNominal Ocular Hazard Distance is less than 35cm
MPE (skin only)~ 3.3MPE. less than maximum allowable of 5MPE
Beam spotElliptical beam spot 2.8mm x 1.1mm (elliptical beam area of = 9.2mm²) at the aperture
DivergenceElliptical beam divergence 18 degrees and 7 degrees
Eye protectionUvex glasses with a minimum of 80% attenuation in the wavelength range of 780nm to 860nm. The Uvex glasses supplied with the unit meet these requirements


Cluster Applicator
ParticularDimensions
SLDTwelve 950nm super luminescent Diodes
LEDSeven 660nm Light Emitting Diodes
Total power500mW ± 50mW
Treatment area illuminationThe 660nm LED;s are visible and illuminate treatment area
Output activationCapacitance Switch on Cluster Applicator handle
Eye protectionUvex glasses with a minimum of 80% attenuation in the wavelength range of 780nm to 1200nm. The Uvex glasses supplied with the unit meet these requirements

Customer Reviews

Questions & Answers


 
 

Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close