Why Choose Invacare Patient Lift?
- Battery-powered boom and base
- Expansive lifting range and safety features make it an ideal choice for most everyday transfers, including from the floor
- Optimized maneuverability is key for a comfortable transfer
- Caregivers can rely on safer operation and residents on maximum comfort during everyday transfers
- Lightweight for ease of use and maneuverability
- Rotating 360° 6-point hanger bar for convenient transfers from the floor
- Supports up to 500 lbs weight capacity
- Boom and base are battery powered with hand pendant
- Hanger bar lets you know when the sling is engaged with an audible sound
- Jasmine Lift User Manual
What Jasmine Premiere Series Full Body Lift Provides?
Stable Spring Loaded Hanger
It produces an audible click when the sling is engaged. This assures the caregiver that the sling is properly attached. That means less stress for the caregiver, a stable transfer for the patient and less likelihood of injury for both. Optimized maneuverability is key for a comfortable transfer. Jasmine lifts feature a battery-powered boom and wide opening base, so caregivers can easily walk behind them and wheelchairs can be accommodated up front. The push handle accommodates any caregiver, and with a lighter-weight aluminum and steel construction, control in movement is straightforward and trouble-free
Lifting Range
This lift expertly functions in more challenging situations with a rotating 360-degree 6-point hanger bar and 16.4"minimum height range, essential for assisting patients who may have fallen to the floor
Maneuverability
The push handle accommodates any caregiver. And with a lighter-weight aluminum and steel construction, control in movement is straight forward and trouble-free
Ease For Caregivers
Jasmine lifts feature a battery-powered boom and wide-opening base, both controlled through the hand pendant
Security
The stable spring-loaded hanger bar produces an audible tone when the sling is engaged.This assures the caregiver that the sling is properly attached
What to Buy with Power Lift?
How to Use Jasmine Mobility Lift?
Assembling the Lift- Do not overtighten mounting hardware
- This will damage mounting brackets
Weight Limitation
- Do not exceed the maximum weight limit of the patient lift
- The weight limitation for the Jasmine Patient Lift is 500 lbs
Using the Sling
- Lift can be used with the standard swivel bar or an optional cradle attachment
- The tilting cradle attachment enables a single caregiver to more easily position a patient in an upright and seated position
- Use an Invacare approved sling that is recommended by the individual’s doctor, nurse or medical assistant for the comfort and safety of the individual being lifted
- After each laundering (in accordance with instructions on the sling), inspect sling for wear, tears, and loose stitching
- Bleached, torn, cut, frayed, or broken slings are unsafe and could result in injury
- Discard immediately
- Do not alter slings
- Be sure to check the sling attachments each time the sling is removed and replaced, to ensure that it is properly attached before the patient is removed from a stationary object (bed, chair or commode)
- If the patient is in a wheelchair, secure the wheel locks in place to prevent the chair from moving forwards or backward. When connecting slings equipped with color-coded straps to the patient lift, the shortest of the straps must be at the back of the patient for support
- Using a long section will leave little or no support for the patient's back
- The loops of the sling are color-coded and can be used to place the patient in various positions
- The colors make it easy to connect both sides of the sling equally
- Make sure that there is sufficient head support when lifting a patient
Operating the Lift- Although recommended that two assistants be used for all lifting preparation, transferring from and transferring to procedures, the equipment will permit proper operation by one assistant
- The use of one assistant is based on the evaluation of the health care professional for each individual case
- Make sure there is an audible click when mounting battery on the battery charger to confirm proper mounting
- Otherwise, injury or damage may occur
- Always keep hands and fingers clear of moving parts to avoid injury
Lifting the Patient- Adjustments for safety and comfort should be made before moving the patient
- Patient's arms should be inside of the straps
- Before transferring a patient from a stationary object (wheelchair, commode or bed), slightly raise the patient off the stationary object and check that all sling attachments are secure
- If any attachment is not correct, lower the patient and correct the problem, then raise the patient and check again
- During the transfer, with the patient suspended in a sling attached to the lift, do not roll caster base over uneven surfaces that would create an imbalance of the patient lift and could cause the patient lift to tip over
- Use steering handle on the mast at all times to push or pull the patient lift
Transferring the Patient- Before transferring, check that the product’s weight capacity can withstand the patient’s weight
- Before transferring a patient from a stationary object (wheelchair, commode or bed), slightly raise the patient off the stationary object and check that all sling attachments are secure
- If any attachment is not correct, lower the patient and correct the problem, then raise the patient and check again
- Before transferring, check that the product that you are transferring the patient to can withstand the patient’s weight
- Wheelchair wheel locks must be in a locked position before lowering the patient into the wheelchair for transport
- Be sure to check the sling attachments each time the sling is removed and replaced, to ensure that it is properly attached before the patient is removed from the bed or chair.
- The mast pivot bolt must be tight to ensure the safe use of the patient lift
- The bolt must be checked at least every six months in conjunction with periodic maintenance
Performing Maintenance- Regular maintenance of patient lifts and accessories is necessary to assure proper operation
- After the first twelve months of operation, inspect all pivot points and fasteners for wear
- If the metal is worn, the parts must be replaced
- Perform this inspection every six months thereafter
- Casters and axle bolts require inspections every six months to check for tightness and wear
Warning: Before using the Patient Sling and Patient Lift, read and understand the Owner’s Manual for proper operation and safety procedures.
Invacare Full Body Lift Specifications
Particulars | Specification |
Height Adjustment | Height At Sling Hook Up: 16.5"-75" H Under The Bed |
Dimensions | 4.75" H Under the Bed Clearance 46.5" W Open 26.5" W Closed 49.75" L |
Caster Options | Casters: 4" |
Product Weight | 98 lbs |
Product Weight Capacity | 500 lbs |
Safety System | Low Battery Alarm: Audio Emergency Controls: Stop, Up and Down |
Battery | 24V DC | Rechargeable | 2 with Unit |
Charger | Charge Time: 6 hr Charger Input: 100-240V AC Charger Output: 29.5 DC |
Jasmine Premiere Series Patient Lift Warranty
3 Year Limited Warranty on Lift and 2 Year Limited Warranty on Electronics
{{x.ShortDescription}} ...