Invacare HomeFill Oxygen Compressor
Invacare HomeFill Oxygen Compressor

Invacare HomeFill Oxygen Compressor

Brand/Manufacturer: INVACARE CORPORATION
Save
Authorized Retailer Badge

Invacare HomeFill Oxygen Compressor is designed to supply pressurized oxygen to fill Invacare proprietary gas cylinders for ambulatory use while the patient receives therapeutic oxygen from an accessory oxygen concentrator. It can fill cylinders for portable use by ambulatory patients. Homefill Compressor provides an unlimited, refillable oxygen supply, and ensures oxygen purity is always greater than 90 percent.

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

Item #DescPkgRewardPrice 
IOH200 20.25"W x 15"H x 16"D Each $87.45
$2245.55
$1749.00

Give me a Better Price

Invacare HomeFill Oxygen Compressor

Includes:

  • Multistage compressor
  • Internal reservoir
  • Inlet fitting
  • Control electronics with an integral oxygen concentration sensor
  • Interlocking fill fitting
  • Drive motor

Key Features:

  • Patient breathes from a continuous flow oxygen concentrator at night
  • Patient protection ensures oxygen purity in cylinder is always greater than 90% 
  • No extra equipment needed because patients can breathe off concentrator while filling cylinders
  • Provides an unlimited refillable ambulatory oxygen supply
  • Encourages compliance with oxygen therapy as patients have no worries about running out of oxygen
  • System is compatible with 5 liter or 10 liter concentrators and a wide variety of cylinder options (Concentrators and cylinders are not included)
  • Eliminating oxygen deliveries increases independence, convenience and comfort
  • Allows the patient to breathe at home from a continuous flow concentrator and then use a convenient ambulatory pack when they are “out and about.”

Also Available (sold separately):


Note: Image shown with cylinder which is not included
Click Here For User Manual

More On HomeFill Oxygen Compressor

Connecting the Cylinder to the Compressor:

  1. Examine the cylinder gauge. If the cylinder pressure is less than 1500 psig, proceed to Step 2.
  2. Set the regulator flow dial on the cylinder to Off.
  3. Remove the cylinder and connector fillport covers (if present).
  4. Momentarily push Down on the outer ring (sleeve) of the connector fillport until Green dots are visible to reset the connector
  5. Grasp the cylinder in the area behind the cylinder fillport.
  6. Position the cylinder in the compressor cradle.
  7. Align the cylinder fillport with the connector fillport.
  8. Pull Up on the outer ring (sleeve) of the connector fillport while pushing Down on the cylinder to couple the cylinder fillport into the connector fillport.

Disconnecting the Cylinder from the Compressor:

  1. Press the compressor power switch to the Off (O) position.
  2. Grasp the cylinder in the area behind the cylinder fillport.
  3. With the other hand, grasp the outer ring (sleeve) of the connector fillport and push Down F.
  4. Lift up on the cylinder to remove from the connector fillport.
  5. When the cylinder fillport is disconnected from the connector fillport, release the outer ring (sleeve) of the connector fillport and use two hands to remove the cylinder from the compressor cradle.
  6. Place the fillport covers onto the connector fillport and cylinder fillport.
  7. Examine the cylinder gauge to ensure cylinder is full (needle pointing into Green area). If the cylinder is not full, perform the following:
    • Repeat Connecting the Cylinder to the Compressor
    • If cylinder is not full after second attempt to fill, contact the provider.

Turning the Compressor On and Off:

  1. Make sure the concentrator is On.
  2. Set the concentrator flow rate to the patient to 3 L/min or less for Platinum 5, XL, and Perfecto2 and 5 L/min or less for Platinum.
  3. Make sure the cylinder is connected to the compressor.
  4. Push the power switch on the control panel to the On ( I ) position.
  5. Examine the control panel. The following sequence of events should occur:
    • 0-3 minutes - The O2 Below Normal (YELLOW) light will be lit while the compressor warms up.
    • After three minutes - The Filling (GREEN) light will be on while the cylinder is filling.
    • The Full (GREEN) light will be on when the cylinder is finished filling.
  6. Remove the full cylinder.
  7. Push the power switch to the Off (O) position.

Specification

Particulars

Details

Electrical Requirements

120 VAC ± 10% at 60Hz

Power Consumption

140 watts

Rated Current Input

2.0amps

Inlet Pressure Rating

14psi to 21psi

Oxygen Output (from concentrator)
5-liter Concentrator:
10-liter Concentrator:


0lpm to 3lpm (while filling cylinders)
0lpm to 5lpm (while filling cylinders)

Oxygen Input

0lpm to 2lpm

Dimensions

20.25"W x  15"H x 16"D

Weight

33 lbs

Cylinder Filling Times (average)

M2: 24 minutes, ML4: 55 minutes, ML6: 75 minutes, M6: 60 minutes, M9: 159 minutes, D: 3.5 hours

Warranty

1 year limited warranty on compressor, 3 year or 5000 hrs (whichever comes first) limited warranty on internal wear components (piston seals and rings, bearings, drive belts, check valves, pressure relief components and electric motor) and control panel.

Customer Reviews

Questions & Answers


 
 

Enter your Answer below.

Security Question: + =
question image
ItemQuestion
ItemName - now

Your question will show here once it will get approved.
answer image
UserAnswer
UserName - now
Your Answer will show here once it will get approved.
question image
Should you use the humidifier on the concentrator when filling your portable tank or should it be disconnected prior to filling?
Sandy Clearo - 10/8/2016 8:48:45 AM
facebooktwitter
answer image
Thank you for contacting customer care service. 
Please refer the Owners manual given on below link.
http://www.invacare.com/doc_files/1100873.pdf
Customer Care - 10/12/2016 2:33:55 AM
question image
Will this fill an E cylinder when attached to a Invacare Platinum XL?
Annette - 7/15/2016 5:05:43 PM
facebooktwitter
answer image
Thank you for contacting customer care service.
No the IOH200 will not fill the E cylinder it is to large.
Customer Care - 7/19/2016 12:26:11 AM
question image
Can I use the oxygen compressor without the oxygen concentrator if all I want to do is fill oxygen tanks?
Ralph - 7/12/2016 12:41:02 PM
facebooktwitter
answer image
Thank you for contacting customer care service.
 It is not possible to use the compressor without a concentrator. There is an Oxygen sensor in the unit that stops filling if the oxygen purity drops below 90%
Customer Care - 7/15/2016 12:30:45 AM
question image
How do you remove tank

Robin - 6/25/2016 1:28:32 PM
facebooktwitter
answer image
Thank you for contacting customer service. 
Please refer page no. 20 given on below link. http://www.invacare.com/doc_files/1100873.pdf
Customer Care - 6/27/2016 5:48:05 AM
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close