InTENSity Micro Combo TENS/MIC Combination Unit
InTENSity Micro Combo TENS/MIC Combination Unit

InTENSity Micro Combo TENS/MIC Combination Unit

Brand/Manufacturer: NORTH COAST MEDICAL
Save
Authorized Retailer Badge

InTENSity Micro Combo TENS/MIC Combination Unit is a simple to operate and portable Microcurrent device that lets the patient switch from TENS therapy to Microcurrent therapy. It combines TENS and Microcurrent allowing patients to treat a wide variety of musculoskeletal issues for pain management.

Item #DescPkgPrice 
DI9698 4.5" x 2.55" x 0.9" Each $75.45 $49.99

Features

  •  InTENSity Micro Combo TENS/MIC Combination Unit includes:
    - A Carrying Case
    - Two sets of lead wires
    - 9-volt battery
    - AC adaptor
    - Manual
    - One year warranty
    - Pack of four self-adhesive reusable electrodes
  • Four modes of TENS
  • Three modes of MIC
  • Power Source: Standard 9-volt battery or AC adaptor
  • Output Voltage: Constant Current
  • Current for TENS: 0-105 mA
  • Current for MIC: 0-700 µA
  • Timer: 1-60 Constant
  • Pulse Width for TENS: 50-300 µs
  • Pulse Width for MIC: 120-200 µs
  • Pulse Rate: 1-150 Hz
  • Wave Form: Monophasic Square
  • Indications For Use:
    - Symptomatic relief of chronic pain
    - Post-traumatic pain
    - Post surgical pain
  • Click Here For Quick Reference Guide

More Information

  • TENS:
    - Tens is a non-invasive, drug-free method of controlling pain that uses tiny electrical impulses sent to the nerves to modify your perception of pain. TENS does not cure any physiological problem; it only helps control pain.
  • MIC:
    - MIC stimulation consists of a very low current sent into the cells of the body. The current is so faint it is measured in millionths of an amp (or microamps) and is often not felt by the user. MIC increases energy production in cells of your body and increases tissue healing rates
  • Instructions For Use:
    1.INSERT BATTERY
    - Press arrow and slide battery compartment cover open.
    - Insert 9V battery, matching the + and – ends to those in unit
    2.CONNECT ELECTRODES TO LEAD WIRES
    - Firmly insert the end of the lead wire pin into the electrode connectors
    - Make sure no bare metal of the pins are exposed
    3.CONNECT LEAD WIRES TO TOP OF DEVICE
    - This unit operates with one or two sets of electrodes
    - When using one set, plug lead wire into Channel 1 on top of the unit
    - Use Channel 2 to operate a second set
    - Both channels may be used to stimulate two different areas at the same time.
    4.PLACE ELECTRODES ON SKIN
    - Remove electrodes from protective backing
    - Keep backing to properly store electrodes after use
    - Apply electrodes to the exact site indicated by your doctor or therapist.
    - Skin at the application site should be clean and dry
    5.TURN DEVICE ON
    - Check that electrodes are securely placed on the skin before activating device
    - Press and release the button in the center of the unit to turn it ON.
    6.SELECT THE THERAPEUTIC MODE
    - There are 2 therapeutic modes available: TENS and MIC.
    - Press the M button and continue to press until you have advanced to your desired therapeutic mode.
    Note: Consult your physician for your suitable therapeutic mode
  • Caution: This is a Class II Medical Device. Federal law restricts these devices to sale by or on the order of a licensed health care professional.

Warranty

One year warranty

Customer Reviews

Questions & Answers


 
 
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.healthproductsforyou.com

Close