Drive Checker Pediatric Compressor Nebulizer has checker cab design that appeals to children. Child-friendly design to encourage therapy compliance. The easy to replace filter is located under the front hood and electrical cord is located under rear hood. It has a powerful, dependable piston powered pump and features very quiet operation. The hood latch doubles as a cup holder.



Click here for 360° view of 18040P.

Click here for 360° view of 18040Y.

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

Item #DescPkgPrice 
18040-Y Yellow, with Disposable Neb Kit Each $54.45 $43.89
18041-Y Yellow, with Reusable and Disposable Neb Kit Each $79.99 $47.99
18040-P Pink, with Disposable Neb Kit Each $60.45 $44.99
18041-P Pink, with Reusable and Disposable Neb Kit Each $79.99 $46.99

Features

  • Drive Checker Pediatric Compressor Nebulizer With Aerosol Mask comes complete with:
    - Mouth piece
    - Pediatric aerosol mask
    - Tubing
    - Two replacement filters
    - Instructions
  • Neb kit includes
    - 7 feet tubing
    - T adaptor
    - Nebulizer or medication cup
    - Reservoir tube
  • Aerosol delivery to manage the symptoms of patients with Asthma, Chronic Lung Disease and Cystic Fibrosis.
  • Note:
    - This product requires a prescription from a licensed medical professional.
    - Prescription can be faxed to 1.203.616.2851 or emailed to [email protected]
  • Also Available (Separately) :
    Drive Disposable Nebulizer Kit (Code : NEBKIT500)
    Drive Reusable Nebulizer Kit (Code : 18254)

More Information

  • Indications For Use
    - Aerosol delivery to manage the symptoms of patients with Asthma, Chronic Lung Disease and Cystic Fibrosis
  • CAUTION: Federal law restricts this device for sale or use on the order of a physician
    To reduce risk of electrocution
    - Always unplug unit immediately after use
    - Do not use while bathing
    - Do not place or store the unit where it can fall or be pulled into a tub or sink
    - Do not place or drop into water or other liquid
    - Do not reach for a product that has fallen into water
    - Unplug immediately
  • WARNING: To reduce risk of electrocution, fire or injury
    - Electrical shock hazard. Do not remove the cabinet or open the cover
    - Disconnect the power cord from the electrical outlet before cleaning or servicing
    - Do not place this equipment near hot, sparking or burning objects. - Do not use oil or grease on or near this device
    - Turn the unit off when it is not in use
    - Keep the cord away from heated or hot surfaces
    - Never drop or insert any object into any opening
    - Never block the air opening of the product or place it on a soft surface, such as a bed or couch where the opening may be blocked
    - Avoid the operation in wet or damp locations
    - Unplug the unit before filling the nebulizer
  • Operating Instructions
    - Place compressor on a stable, sturdy and flat surface such that the unit can be easily reached when you are seated
    - Pull out the power cord from the base of the unit and make sure that the unit is in the OFF (O) position by pressing on the left side of the switch
    - Plug the power cord into a 115 VAC/60 Hz wall outlet
    - Connect one end of the nebulizer tubing into the air outlet connector
    - Add the prescribed medication through the opening on cap using an eyedropper or pre-measured dose container
    - Assemble mouthpiece and T-piece and insert into the top of the nebulizer cap. If an aerosol mask is used, connect the bottom of the mask to the top of the nebulizer cap
    - Connect the tubing to nebulizer air inlet connector
    - Turn the power on to start the unit
    - Implement the treatment by placing the mouthpiece between the teeth. Inhale and exhale through the mouthpiece
    - If aerosol mask is used, place mask over the mouth and nose
  • Cleaning
    - Turn the power off and unplug from the wall outlet
    - Remove the tubing from the air inlet
    - Disassemble mouthpiece, T-piece, nebulizer cap, chamber and baffle, and wash in hot water with dish washing soap. Rinse thoroughly
    - Mix one part of white vinegar with three parts water in a clean container. Submerge mouthpiece, T-piece, nebulizer cap, chamber and baffle cap for one half hour
    - Remove the components from the solution an let dry
  • Maintenance
    - The filter of air compressor should be replaced when it turns grey. Additional filters can be purchased from the dealer or pharmacy that you purchased the device from
    - A certified technician should make repairs only

Specification

ParticularsSpecifications
Method of NebulizationPiston Compressor
Particle Size0.5µm to 10µm
Unit Dimensions4.3" (D) x 7.7" (H) x 11.8" (W)
Weight3.7lb
Maximum Pressure30 PSI
Operating Pressure16 PSI
Liter Flow8 LPM
Power115V AC/60HZ
Power Consumption75W
Sound Pressure Level<53dBA
Particle SizeLess than 5 microns
Electrical Requirements115V AC/60HZ
Power Consumption:75W
NOTE: Conditions may vary based on altitude, barometric pressure and temperature.