Drive Airial Fire And Rescue Compressor Nebulizer

Authorized Retailer Badge

Options

Item# Description Pkg availability reward$ Price Blank
Item #: MQ0911
With Disposable Neb Kit
Each
Each In stock
reward$
$3.13
$81.29
$62.53
Measure your peak flows and save yourself from an emergency room visit!

Drive Fire And Rescue Compressor Nebulizer is intended for use with a single adult, pediatric, or infant patient. This product creates a stream of air that travels through a clear tube to the nebulizer. When air enters the nebulizer, it will convert the prescribed medication into aerosol mist for easy inhalation. It is quiet, easy to use and is piston driven system.

Drive Airial Compressor Nebulizer Features

  • Drive Fire And Rescue Compressor Nebulizer has unique child friendly design, with reflective lights and ladder
  • Encourage patient compliance by stimulating the childs imagination, which helps to eliminate stress and anxiety during treatments
  • Fun for all ages, providing patients with years of reliable service
  • Storage compartment in cab
  • Comes with:
    • Pediatric mask
    • Disposable nebulizer kit
    • Tubing
  • Disposable nebulizer kit includes:
    • 7 feet tubing
    • T adaptor
    • Nebulizer or medication cup
    • Reservoir tube
    • Mouthpiece

Airial Compressor Nebulizer Guides


Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here


What to buy with Airial Fire Engine Nebulizer System?


How to Operate Fire and Rescue Compressor Nebulizer?

Important: Prior to initial operation, this product should be thoroughly cleaned per the Cleaning Procedures in this guidebook
  1. Place your compressor Nebulizer on a at and stable surface. Be sure that you can easily reach the controls when you are seated
  2. Fill the bottom section of the nebulizer cup with the medication prescribed by your Physician. Be sure that the cone is put inside the bottom section. Place the cone inside and ll medication
  3. Gently twist the top part clockwise to reassemble the nebulizer cup. Be sure the two sections t well
  4. Attach one end of air tube to the base of the nebulizer cup
  5. Attach the other end of airtube to the air tube connector located on the back of the compressor
  6. Attach the interface accessory of your choice to the top section of the nebulizer cup
  7. Plug the power cord into an appropriate electrical outlet. Make sure at this stage, the power switch is at OFF status
  8. Press the power switch to ON status to begin your prescribed treatment
  9. Important: The compressor motor has a thermal protector, which will shut off the unit before the unit is overheated. When the thermal protector shuts the unit off, please
    • Switch off the unit
    • Unplug the unit from the electrical outlet
    • Wait 30 minutes for the motor to cool down before another treatment
    • Make sure the air openings are not obstructed
  10. When treatment is finished, shut o the unit and unplug it from the electrical outlet

How to Clean Airial Nebulizer?

  • It is recommended that the nebulizer and the mask (or any other patient accessory interface that is used) be thoroughly cleaned with hot water after each use and cleaned with a mild detergent after the last treatment of the day
  • If your physician or respiratory therapist species a dierent cleaning procedure, follow their instructions

Rinsing (after each treatment)

  • Disconnect the air tube from the nebulizer cup. Disconnect the mask or other patient accessory interface from the nebuilzer cup
  • Gently twist the top part of the nebulizer cup counter-clockwise to disassemble the nebulizer
  • Rinse the nebulizer cup and mask (or other patient interface) with water
  • Let these components air dry, away from direct sunlight
  • Reassemble the nebulizer cup when completely dry and put these parts in a dry, sealed container

Disinfecting

  • Use one part white vinegar with three parts distilled water. Make sure mixed solution is enough to submerge the nebulizer, mouthpiece and mask
  • Complete Rinsing Steps 1-3
  • Wash nebulizer, mouthpiece and mask in warm water and a mild detergent. Then wash them in hot tap water
  • Submerge these parts in the vinegar and water solution for thirty minutes
  • Complete Rinsing Steps 3-5

Airial Compressor Nebulizer Cautions

To avoid electrical shock
  1. Keep the unit away from water
  2. Do not immerse the power cord or the unit in liquid
  3. Do not use while bathing
  4. Do not reach for a unit that has fallen into water - immediately unplug the unit
  5. Never operate the unit if it has any damaged parts (including power cord), or if it has been dropped or submersed in water. Promptly send it to a service center for examination and repair
  6. The unit should not be used where products are being used
  7. Disconnect the unit from the electrical outlet before clean after each use
  8. Do not use other attachments unless recommended by manufacturer
  9. This appliance has a polarized plug (one blade is wider than the other)

Operating Cautions

  1. Connect this product to an appropriate voltage outlet for your model
  2. Do not run this product unattended
  3. Never operate the unit if it has any damaged parts (including power cord), or if it has been dropped or submersed in water. Promptly send it to a service center for examination and repair
  4. If any abnormality occurs, discontinue use immediately until the unit has been examined and repaired
  5. Always unplug the product immediately after use
  6. Never block the air openings of the main unit or place it where the air openings may be obstructed

Storage Cautions

  • Do not store the unit in direct sunlight, high temperatures, or high humidity
  • Keep the unit out of reach of small children
  • Always keep the unit unplugged while not in use

Cleaning Cautions

  • Do not immerse the unit in water. It may damage the unit
  • Disconnect the unit from the electrical outlet before cleaning
  • Clean all necessary parts after each use as instructed in this guidebook

Fire And Rescue Compressor Nebulizer Specifications

ParticularsSpecifications
PowerAC 120V, 60Hz
Current1.5 A / 0.8 A
Medication Capacity5ml
Particle Size0.5 to 10µm
MMAD4 µm
Sound LevelAround 60 dBA
Maximum Medication capacity13ml (cc)
Average Nebulization Rate0.2ml/min
Compress or Pressure Range25 to 42 Psi
Operating Pressure Range8 to 13 Psi
Liter Flow Range5 ~ 8 lpm
Operating Temperature Range10°C to 40°C (50°F to 104°F)
Operating Humidity Range10 to 95% RH
Storage Temperature Range-20°C to 70°C (-4°F to 158°F)
Storage Humidity Range10 to 95 % R H
Dimension (L x W x H)319 mm x141 mm x170 mm (12.56”L x 5.55”W x 6.69”H)
Weight4.96lb

Firetruck Nebulizer Warranty

5 year limited warranty

Customer Reviews

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close