Respironics DreamStation Automatic CPAP Machine Features
- EZ-Start - EZ-Start is an acclimation algorithm for Fixed and Auto CPAP. It can help patients gradually adapt to their prescribed level of therapy using an innovative pressure acclimation algorithm with automatic, personalized adjustments to CPAP pressure over the first 30 days.
- FLEX - Flex technology is a comfort feature that provides pressure relief during therapy. C-Flex was clinically shown to increase nightly usage by 1 hour and 42 minutes compared to traditional CPAP therapy.
- SmartRamp - SmartRamp utilizes an Auto titrating algorithm during the ramp period which allows patients the ability to stay at lower pressures during the ramp period, to improve their acclimation to therapy.
- Opti-Start - An Auto CPAP algorithm that provides optimal starting pressure to enhance patient comfort and reduce the likelihood of residual events at the beginning of therapy and throughout the night.
- CPAP-Check - A fixed CPAP algorithm that recognizes long-term changes in patients' pressure needs and automatically adjusts the fixed pressure to improve treatment. This can save the clinician time since the pressures are changed automatically.
What to buy with DreamStation CPAP
Why choose Dream Station Auto CPAP?
- Connectivity: options offer more monitoring choices than any leading CPAP brand with integrated Bluetooth on every device, and offering optional Wi-Fi and cellular modems.
- Performance Check: simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service.
- Daily Progress Feedback: displays a simple trend of patients’ nightly use to help track progress on the path to adherence.
- Humidification
- Fixed, adaptive, heated tube
- Pre-heat humidifier option
- Modular design with one-piece, dishwasher-safe water chamber
DreamStation CPAP Machine Additional Features
- Advanced event detection
- Mask type resistance control
- Mask fit check
- Oximetry capable
- DreamMapper patient self-management system compatibility
- CPAP-Check
- Auto-Trial
- Digital AutoTrak
- Waveform data
How can dream DreamMapper help?
- Sync devices: Data is easily synced and available through smartphones, tablets, or computer
- Track progress: Patients can monitor the progress of custom goals they set for themselves
- View data: Patients can see their therapy data quickly and easily
- Set reminders: Patients can set reminders for important tasks, including mask, tube and filter cleaning
- Troubleshoot: Troubleshoot common problems
- Inspire patients: Tools to help encourage adherence
Dream Station Auto CPAP Machine Parts
- Therapy On/Off Button - Starts and stops the airflow for therapy. If the Therapy On/Off button LED is flashing, you may have a pending message. Press or turn the knob to display the message.
- Ambient Light Sensor - Detects room light levels and adjusts the brightness of LCD Display Screen
- Ramp Button - Activates the ramp feature during therapy
- Door, SD card & Filter Access - This door lifts open for access to the SD card and filter area
- LCD Display Screen - This is the User Interface for the therapy device
- Control Dial - Turn the dial to scroll between options on the screen. Press the dial to choose an option
- Door, Accessory Access - This door lifts open for access to the (optional) accessories
- Humidifier Connector - Humidifier connects to the back of the therapy device
- Air Outlet Port - Connect the tubing
- Power - Inlet Connect the power cord

Respironics DreamStation Auto CPAP Manuals
How to clean Respironics CPAP Machine?
- Unplug the device, and wipe the outside of the device with a cloth slightly dampened with water and a mild detergent. Let the device dry completely before plugging in the power cord.
- Inspect the device and all circuit parts for damage after cleaning. Replace any damaged parts.
How to care for filters of DreamStation CPAP Device?
Under normal usage, you should rinse the reusable blue pollen filter at least once every two weeks and replace it with a new one every six months. The disposable light-blue ultra-fine filter should be replaced after 30 nights of use or sooner if it appears dirty or damaged. DO NOT rinse the ultra-fine filter.
- If the device is operating, stop the airflow. Disconnect the device from the power source.
- Remove the filters from the device
- Take the reusable filter to a sink, turn it upside down, and run warm tap water through the white middle portion of the filter to rinse away any debris.
- Shake the filter to remove as much water as possible
- Allow the filter to air dry completely before reinstalling it. If the filter is damaged, replace it. (Only Philips Respironics-supplied filters should be used as replacement filters.)
- Reinstall the filters
Compare your DreamStation CPAP Machines
|
DreamStation Auto CPAP |
DreamStation BiPAP Pro |
DreamStation Auto BiPAP |
DreamStation CPAP Pro |
Modes |
Fixed CPAP, CPAP, Check, Auto-CPAP |
Fixed CPAP, Fixed BiPAP |
Fixed CPAP, Fixed BiPAP, Auto-BiPAP |
Fixed CPAP, CPAP-Check |
Features |
EZ-Start, Auto-Trial, Opti-Start |
EZ-Start |
EZ-Start |
EZ-Start, Auto-Trial |
Pressure Range |
4 to 20 cm H2O |
4 to 25 cm H2O |
4 to 25 cm H2O |
4 to 20 cm H2O |
Flex Comfort |
C-Flex, C-Flex+,A-Flex |
C-Flex, C-Flex+, Bi-Flex |
C-Flex, C-Flex+, Bi-Flex |
C-Flex, C-Flex+ |
Humidification Modes (3) |
Fixed, Adaptive, Heated Tube |
Fixed, Adaptive, Heated Tube |
Fixed, Adaptive, Heated Tube |
Fixed, Adaptive, Heated Tube |
Mask Type Resistance Control |
Standard |
Standard |
Standard |
Standard |
Ramp (0-45 minutes) |
Ramp SmartRamp |
Ramp SmartRamp |
Ramp SmartRamp |
Ramp SmartRamp |
Altitude Compensation |
Automatic |
Automatic |
Automatic |
Automatic |
Advanced Event Detection |
Standard |
Standard |
Standard |
Standard |
Flow Waveforms |
Standard |
Standard |
Standard |
Standard |
Modem Compatibility |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Built-in Bluetooth Connectivity |
Standard |
Standard |
Standard |
Standard |
DreamMapper Compatibility |
Standard (by mobile app or web) |
Standard (by mobile app or web) |
(by mobileStandard (by mobile app or web) |
Standard (by mobile app or web) |
Oximetry Compatibility |
Standard (optional Nonin accessories) |
Standard (optional Nonin accessories) |
Standard (optional Nonin accessories) |
Standard (optional Nonin accessories) |
Check Mask Fit feature |
Standard |
Standard |
Standard |
Standard |
Performance Check |
Standard |
Standard |
Standard |
Standard |
DreamStation Auto CPAP Machine Specifications
Particulars |
Specifications |
Modes |
Auto CPAP |
Features |
N/A |
Pressure Range |
4 to 20 cm H2O |
Flex Comfort |
C-Flex |
Humidification Modes (3) |
Fixed Adaptive
Heated Tube |
Mask Type Resistance Control |
Standard |
Ramp (5-45 minutes) |
Standard SmartRamp |
Altitude Compensation |
Automatic |
Advanced EventDetection |
N/A |
Flow Waveforms |
N/A |
Modem Compatibility |
Standard (optional Cellular Modem or Wi-Fi Accessory) |
Built-in Bluetooth Connectivity |
Standard |
DreamMapper Compatibility |
Standard (by mobileapp or web) |
Oximetry Compatibility |
Standard (optional Nonin accessories) |
Check Mask Fit feature |
N/A |
Performance Check |
Standard |
Dimensions - Machine Alone |
6.2 in L x 7.6 in W x 3.3 in H
(15.7 cm L x 19.3 cm W x 8.4 cm H) |
Dimensions - Machine and OPTIONAL Humidifier (Excluding Air Outlet Port) |
11.7 in L x 7.6 in W x 3.3 in H
( 29.7 cm L x 19.3 cm W x 8.4 cm H) |
Weight - Machine Alone |
1.56 lbs (0.71 kg) |
Weight - Machine and Power Supply |
2.94 lbs (1.33 kg) |
Dimensions - 80W Power Supply |
5.5 in L x 2.75 in W x 1.5 in H |
Weight - 80W Power Supply (Without Cord) |
1.03 lbs (16.42 oz) |
Weight - 80W Power Supply (With Cord) |
1.21 lbs (19.424 oz) |
Power Consumption: 80W Power Supply |
100 – 240 VAC, 50/60 Hz, 2.0-1.0 A |
Noise Level |
Machine Alone: 25.8 dBA |
Noise Level - Machine with Optional Humidifier |
27.9 dBA |
Water Capacity - OPTIONAL Humidifier |
325 mL |
Materials - Reusable Filter (Dark Blue) |
Polyester |
Materials - Disposable Filter (Light Blue) |
Blended Synthetic Fiber |
Operating Temperature |
41° - 95° F (5° - 35° C) |
Storage Temperature |
-4° - 140° F (-20° - 60° C) |
Relative Humidity - Operating & Storage |
15 - 95% (Non-Condensing) |
Atmospheric Pressure |
101 - 77 kPA (0 - 7500 ft) |
Philips Respironics DreamStation Auto CPAP Warranty
Beyond our included 2-year warranty, an extended 3-year warranty option is available for purchase to give your patients additional peace of mind
DreamStation Auto CPAP Reviews
{{x.ShortDescription}} ...
Share