Get 10% OFF*, Use Code: HPDIS10

Day
:
:
Online since 2002 |   866-316-0162

View product option
MIC-KEY 18FR Low-Profile Gastrostomy Feeding Tube kit Buy Mic-Key 18fr Gastrostomy Feeding Tube Kit MIC-KEY 18FR Low-Profile Gastrostomy Feeding Tube kit

MIC-KEY 18FR Low-Profile Gastrostomy Feeding Tube kit

Authorized Retailer
Product Option

Stoma Length 0.8cm

SKU 0120-18-0.8
$141.99 Each

Stoma Length 1.0cm

SKU 0120-18-1.0
$139.69 Each

Stoma Length 1.2cm

SKU 0120-18-1.2
$139.69 Each

Stoma Length 1.5cm

SKU 0120-18-1.5
$139.69 Each

Stoma Length 1.7cm

SKU 0120-18-1.7
$139.69 Each

Stoma Length 2.0cm

SKU 0120-18-2.0
$139.69 Each

Stoma Length 2.3cm

SKU 0120-18-2.3
$139.69 Each

Stoma Length 2.5cm

SKU 0120-18-2.5
$139.69 Each

Stoma Length 2.7cm

SKU 0120-18-2.7
$169.99 Each

Stoma Length 3.0cm

SKU 0120-18-3.0
$139.69 Each

Stoma Length 3.5cm

SKU 0120-18-3.5
$139.69 Each

Stoma Length 4.0cm

SKU 0120-18-4.0
$169.99 Each

Stoma Length 5.0cm

SKU 0120-18-5.0
$139.69 Each
Request quote

MIC-Key Low-Profile Gastrostomy Feeding Tube Kit 18 FR is a medical device designed for enteral feeding and medication administration. The kit consists of a silicone feeding tube, an insertion tool, and a syringe. The tube is inserted through the skin and into the stomach, providing a means of delivering nutrition, hydration, and medication directly into the gastrointestinal tract.

What does MIC-Key Gastrostomy Feeding Tube 18FR Include?

  • MIC-KEY* Low-Profile Gastrostomy Feeding Tube
  • Insertion Stylet (US Only)
  • Water-soluble Lubricant (US Only)
  • Continuous Feed Extension Set, 12-inch
  • Bolus Feed Extension Set, 12-inch
  • 6ml Luer Slip Syringe
  • 35ml Enteral Feeding Syringe
  • Gauze Pad

Autoship

$116.99 $191.65

20% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $7.10 in HPFY rewards

One-time purchase

$141.99 $191.65

Earn $7.10 in HPFY rewards

MIC-Key Low-Profile Gastrostomy Feeding Tube Kit 18 FR Features

  • Mickey gastrostomy feeding tube is not made with natural rubber latex and sterile
  • Less cumbersome than conventional G-tubes for active patients
  • The low profile design of the MIC KEY button g tube makes it unobtrusive & easier to conceal
  • Tapered distal tip recessed at a recommended fill volume
  • Inflatable silicone internal retention balloon reduces patient trauma experienced with obturated devices
  • Ventilated secur-lok ring, the external retention mechanism designed to allow air to circulate around the stoma site and reduce tube pressure 360 degrees from the sides of the stoma wall
  • Radiopaque stripe
  • Patented universal connector, designed to preserve tube life & minimize unintentional disconnects
  • Single patient use
  • Indicated for use in patients who require:
    • Enteral feeding,
    • Patients are unable to tolerate oral feeding,
    • Require gastric decompression and/or medication delivery directly into either the stomach, distal to the stomach, distal duodenum, or proximal jejunum (tube types vary from G, J, TJ/ GJ & GE depending on what medical professional has prescribed/placed).

Who should use a Gastrostomy Feeding Tube?

A gastrostomy feeding tube may be recommended for individuals who are unable to consume adequate nutrition and hydration orally due to various medical conditions, such as:

  • Neurological conditions, such as stroke, multiple sclerosis, or Parkinson's disease, can affect the ability to swallow.
  • Head and neck cancers can make it difficult to swallow or cause blockages in the digestive system.
  • Gastrointestinal disorders, such as Crohn's disease or ulcerative colitis, can cause malabsorption of nutrients.
  • Severe burns or injuries that make it difficult to eat or drink.
  • Developmental disabilities, such as cerebral palsy, can affect the ability to swallow or process food.

Frequently Bought Together


How to use MIC KEY Low Profile G Tube?

  1. Attach - To start, attach the MIC-KEY G Extension Set to the MIC-KEY G feeding port by matching the black lines on the extension set and feeding port. Push the extension set down firmly and “lock” it into place by turning the connector CLOCKWISE until you feel a slight resistance (approximately three-quarters turn).
    Note - Do not turn the connector past the stop point. It is important to keep the extension set “locked” into place during feeding.
locking the extension set
  1. Flush - Next, flush your MIC-KEY G Extension Set with water. Use either extension set to flush.
  2. Begin - Now begin enteral feeding.
    • For bolus feeding - Attach a bolus syringe filled with your preferred nutrition.
    • For continuous feeding- Attach a feeding set to a feeding pump with your preferred nutrition in the bag.

How to remove Extension Set From MIC Tube?

  • Disconnect the extension set from the Gastrostomy Feeding Tube 18 FR port by rotating it COUNTER-CLOCKWISE until the black line on the feeding port lines up with the black line on the extension set.
  • Gently detach the extension set and cap the MIC-KEY G Feeding Tube securely with the attached feeding port tube cover.
    Cautions -
    • It is recommended to connect only the MIC-KEY Extension Set to the MIC-KEY G Feeding Tube.
    • To avoid damage, do not insert medication or nutrition directly into the feeding port valve without the use of an extension set.
    • Flush the tube and extension sets before and after every use to prevent clogging.
Removing extension set
 

How to care?

Stoma Site:

  • Wash hands thoroughly with warm, soapy water before touching the feeding tube
  • Clean the skin around and under the MIC-KEY G feeding tube daily using mild soap, water, and a soft, lint-free cloth or cotton-tipped applicator
    Note - Avoid puncturing or tearing any part of the tube or extension sets

MIC KEY G Tube & Port:

  • Clean the external portion of the tube
  • Be careful not to pull or manipulate the tube excessively
  • Make sure both your tube and stoma are kept clean and dry

Tips for using Gastrostomy Feeding Tube 18 FR

  • To avoid a “balloon burst,” use your MIC-KEY G Feeding Tube, as indicated in the Instructions for Use (IFU)
  • To avoid damage, always use the correct equipment. Only use the extension sets as instructed by a clinician. Only use a syringe for its intended purpose.
  • Replace extension sets as per the IFU.
  • Only use sterile or distilled water to fill your balloon.
  • A medical professional will determine the proper length of the tube by using a stoma-measuring device and then recommend the proper length. If there are issues with the tube or stoma, or significant weight is gained or lost, contact your care team. A new measurement could be required.
  • The external base of the feeding tube should rest just above the skin surface. A good fit is considered 1 to 2 mm above the skin, about the thickness of a dime. If the external base is sitting too low or high, contact your clinician to see if you need to be re-measured.
  • Refer to the IFU or the first page of this guide for the inflation volumes of your balloon. It will vary based on tube size.
  • Only use a water-soluble lubricant.
  • The MIC-KEY Tube Feeding features an anti-reflux valve, located toward the top of the feeding port. When you attach the extension set, this valve is opened to allow feeding. It is important to keep both the feeding port and the anti-reflux valve clean with proper flushings.
  • To avoid valve damage, do not insert medication or nutrition directly into the feeding port valve.

Contraindications: Contraindications for placement of a Mic-Key feeding tube include but are not limited to ascites, colonic interposition, portal hypertension, peritonitis, and morbid obesity.


Frequently Asked Questions

  1. What is the purpose of the MIC-KEY Gastrostomy Feeding Tube Kit?

    The MIC-Key Low-Profile Gastrostomy Feeding Tube Kit 18 FR is used to provide a way to deliver nutrition, hydration, and medication directly to the gastrointestinal tract of patients who are unable to take food or medications orally.

  2. Is the MIC KEY G Tube Kit safe?

    The MIC-KEY Gastrostomy Feeding Tube Kit is designed to be safe and is used widely in hospitals, clinics, and homes around the world. However, as with any medical device, there are potential risks and complications associated with its use. It is important to follow the instructions provided by your healthcare provider or the manufacturer and to report any concerns or issues immediately.

  3. How long does this last?

    The MIC-KEY G Tube is a long-term feeding tube and can remain in place for several months or even years. However, it is important to follow the care instructions provided by the healthcare provider or the manufacturer to ensure the tube stays clean and functional.

  4. How is the MIC-KEY 18FR Low-Profile Gastrostomy Feeding Tube Kit inserted?

    It is inserted through the skin and into the stomach using a procedure called a gastrostomy. The insertion is performed by a healthcare professional, and patients are given instructions on how to care for the tube after insertion.

  5. Can the MIC-KEY Gastrostomy Tube be used for medication administration?

    Yes, the MIC-KEY Feeding Tube can be used to administer medication directly into the stomach.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

MIC-KEY Gastrostomy Feeding Tube 18FR Reviews

More Gastro-Enteric Feeding Tubes

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close