Free Shipping* Above $50 Code: HPFY50

Day
:
:
Online since 2002 |   866-316-0162

View product option

Bard Bardia 2-Way Silicone-Elastomer Coated Foley Catheter With 30cc Balloon Capacity

Brand: BARD INC SKU: 123612A
Authorized Retailer
Product Option

12FR

SKU 123612A
$2.03 Each

12FR

SKU 123612A
$15.19 12/Pack

12FR

SKU 123612A
$121.39 96/Case

14FR

SKU 123614A
$2.03 Each

14FR

SKU 123614A
$16.33 12/Pack
$1.36 Each

14FR

SKU 123614A
$129.02 96/Case
$1.34 Each

16FR

SKU 123616A
$2.03 Each

16FR

SKU 123616A
$16.33 12/Pack
$1.36 Each

16FR

SKU 123616A
$130.53 96/Case
$1.36 Each

18FR

SKU 123618A
$1.39 Each

18FR

SKU 123618A
$16.12 12/Pack
$1.34 Each

18FR

SKU 123618A
$123.11 96/Case
$1.28 Each

20FR

SKU 123620A
$2.14 Each

20FR

SKU 123620A
$23.65 12/Pack
$1.97 Each

20FR

SKU 123620A
$182.78 96/Case
$1.9 Each

22FR

SKU 123622A
$2.03 Each

22FR

SKU 123622A
$16.33 12/Pack
$1.36 Each

22FR

SKU 123622A
$130.53 96/Case
$1.36 Each

24FR

SKU 123624A
$2.03 Each

24FR

SKU 123624A
$16.33 12/Pack
$1.36 Each

24FR

SKU 123624A
$130.53 96/Case
$1.36 Each

26FR

SKU 123626A
$2.03 Each

28FR

SKU 123628A
$2.03 Each

28FR

SKU 123628A
$16.33 12/Pack
$1.36 Each

28FR

SKU 123628A
$117.04 96/Case
$1.22 Each

30FR

SKU 123630A
$2.03 Each

30FR

SKU 123630A
$14.19 12/Pack
$1.18 Each

30FR

SKU 123630A
$130.53 96/Case
$1.36 Each
Request quote

Bard Bardia Silicone Elastomer Latex Coated Foley Catheter is a 2-way 30cc ballon capacity catheter that is used to drain urine from the bladder. It is coated with a silicone-elastomer material which makes it smooth and easy to insert and reduces the risk of irritation or injury to the urethra. The catheter has a 30cc balloon capacity, which means that it can hold up to 30 milliliters of sterile water or saline solution in its balloon at the tip of the catheter. When the balloon is inflated, it holds the catheter in place in the bladder, preventing it from slipping out. The catheter is called a "2-way" catheter because it has two channels or lumens, one for inflating the balloon and the other for draining urine. This type of catheter is commonly used in medical settings, such as hospitals or nursing homes, for patients who are unable to urinate on their own.

Benefits of Bardia 2-Way Foley Catheter

  • 30cc balloon capacity
  • Latex-based construction
  • Medium length
  • Rounded catheter tip
  • Sterile

Autoship

$1.62 $3.05

20% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $0.10 in HPFY rewards

One-time purchase

$2.03 $3.05

Earn $0.10 in HPFY rewards

Bardia Silicone Elastomer Coated Latex Foley Catheter Features

  • Two opposing eyes for drainage
  • Rigid latex is easier to insert
  • Permanent coating
  • Reduces urethral irritation
  • Has a smooth surface
  • Easy-to-use Foley catheter
  • Peel apart packaging
  • Meant for single use

Frequently Bought Together


How to Inflate and Deflate Foley Catheters?

Inflation Instructions:

  • Ensure that the  catheter balloon is positioned well within the bladder of the patient
  • Slowly, with a gentle, constant force, inflate the catheter balloon with the volume prescribed on the package
  • Note that the 30cc balloon must be inflated with 35cc of sterile water
  • Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties
  • Using fluid other than sterile water may cause the balloon not to empty properly, especially after long dwell times
Bardia 2-Way Silicone-Elastomer Coated Foley Catheter With 30cc Balloon Capacity
Properly Inflated
Bardia 2-Way Silicone-Elastomer Coated Foley Catheter With 30cc Balloon Capacity
Under Inflated
 

Deflation Instructions:

  • Select a luer lock or slip-tip syringe
  • Slide the plunger of the syringe up and down the barrel of the syringe several times to "loosen it up"
  • Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
  • Gently insert the syringe into the catheter valve
  • Do not use more force than is required to make the syringe "stick" in the valve
  • Allow the pressure within the balloon to force the plunger back and fill the syringe with water
  • If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own
  • If the balloon does not deflate, reposition the patient
  • Ensure that the Bardia 2-way silicone-elastomer coated Foley catheter is not in traction- the proximal end of the catheter is not compressed within the bladder neck
  • Ensure that urine flows freely
  • Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above
  • If the balloon still fails to deflate, apply very gentle slow aspiration. The aspiration that is too rapid, or too forceful, may cause the inflation lumen within the Foley catheter to collapse.
  • If permitted by hospital protocol, the valve arm may be severed
  • If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Precautions:

  • Do not use ointments or lubricants having a petrolatum base. They will damage the catheter.
  • Visually inspect the product for any imperfections or surface deterioration prior to use
  • Inflate the balloon with sterile water to the volume stated on the inflation lumen of the catheter by using a water-filled Luer tip syringe
  • Do not use a needle
  • Do not exceed recommended capacities

Frequently Asked Questions

1. How is the Bard Bardia Silicone Elastomer Latex Coated Foley Catheter inserted?

It is inserted through the urethra into the bladder. It is then held in place by inflating the balloon with sterile water or saline.

2. How long can the Bard Foley Catheter be left in place?

The duration for which the Bard Bardia Foley Catheter can be left in place varies depending on the individual's needs and medical condition. Generally, it can be left in place for up to 30 days, but it is essential to follow the healthcare provider's instructions regarding catheter care and removal.

3. Can this catheter be reused?

No, it is designed for single use only and should be disposed of after use. Reusing catheters can increase the risk of infection and other complications.

4. What are the benefits of using a silicone-elastomer-coated Foley catheter?

These catheters are associated with a lower risk of urinary tract infections and other complications compared to uncoated catheters. The coating reduces the adherence of bacteria to the catheter surface and makes it easier to insert and remove the catheter.

Bardia Foley Catheter Specifications

Particulars Specifications
Catheter Tip Round Tip
Catheter Material Latex
Gender Unisex
Catheter Coating Silicon Coated
Catheter Style Coated Catheters
Catheter French Size 12FR, 14FR, 16FR, 18FR, 20FR, 22FR, 24FR, 26FR, 28FR, 30FR
Balloon Size (CC) 30cc
Drainage Eyes 2 Opposing Drainage Eyes

 

 

 

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Bardia 2-Way Foley Catheter Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close